background image

P/N 1062783 • REV B • ISS 01JUL11

VT7820-2DRDT
VT7820-2DRDT-R3
VT7830-2DRDT
VT7830-2DRDT-R3

IFS Fiber Module 
Installation & Operation 
Instructions

VR7820-2DRDT
VR7820-2DRDT-R3
VR7830-2DRDT
VR7830-2DRDT-R3

Summary of Contents for VR7820-2DRDT

Page 1: ...P N 1062783 REV B ISS 01JUL11 VT7820 2DRDT VT7820 2DRDT R3 VT7830 2DRDT VT7830 2DRDT R3 IFS Fiber Module Installation Operation Instructions VR7820 2DRDT VR7820 2DRDT R3 VR7830 2DRDT VR7830 2DRDT R3 ...

Page 2: ...6 5 4 3 2 1 Data Output ON OFF ON 2 1 RS422 DATA Data In Data In 7 6 5 4 3 2 1 Data Out Data Out Data In Out Data In Out 7 6 5 4 3 2 1 2 WIRE RS485 DATA 4 WIRE RS485 DATA Data In Data In 7 6 5 4 3 2 1 Data Out Data Out ON OFF OFF ON ON OFF ON ON ON ...

Page 3: ...RS422 4W RS485 RS232 DATA IN OUT 7 DATA IN OUT 6 DATA OUT 5 DATA IN 4 DATA OUT 3 DATA OUT 2 1 RS422 2W RS485 RS422 4W RS485 RS232 ON ON 1 2 sw 232 422 2w 485 4w 485 OFF OFF OFF OFF ON ON VR7830 2DRDT 8 CHANNEL DIGITAL VIDEO TRANSMITTER 2 CHANNEL DATA TRANSCEIVER 2 12 VDC 1 POWER ifs International Fiber Systems Incorporated DATA IN OUT 7 DATA IN OUT 6 DATA OUT 5 DATA IN 4 DATA OUT 3 DATA OUT 2 1 RS...

Page 4: ...ical data received Electrical data transmitted Camera on Video Present Optical carrier received Power Status indicating LEDs will change from RED to GREEN with these conditions VT VR VT VR VT VR VT VR VT VR VT VR VT VR VT VR VR7800 2DRDT NOTE WITHOUT PROPER FIBER CONNECTION LED s DO NOT INDICATE CORRECT OPERATIONAL STATUS OF THE UNIT ...

Page 5: ...US A B C D E B A C D E Optical data received Electrical data transmitted Optical carrier received Camera on Power Status indicating LEDs will change from RED to GREEN with these conditions A OFF 1 2 TX RX CH 1 CH 2 CH 3 CH 4 OPTICAL CARRIER VT7800 2DRDT ...

Page 6: ...N REQUIREMENTS ON THE VT78XX 2DRDT R3 and VR78XX 2DRDT R3 Series RACK MOUNT UNITS INSTALL SUPPLIED CONDUCTIVE FOAM GASKET IFS P N MMRFGSKT 375X500 or CHOMERICS P N 82 122 74021 09600 CUT TO 4 INCH LENGTH AND PLACE ON TOP RAIL OF THE RACK WHERE THE UNIT IS TO BE INSTALLED GASKET ...

Page 7: ...ONS FOR ADDITIONAL COMPONENTS REQUIRED TO MEET EMISSION REQUIREMENTS ON THE VR78XX 2DRDT Series STAND ALONE UNIT INSTALL SUPPLIED EMI FILTER CLAMPS IFS P N FL28A0640 0A0 or STEWARD P N 28A0640 0A0 ON EACH DATA CABLE AS SHOWN ...

Page 8: ...s reasonable efforts the parties will negotiate an equitable adjustment in price d The preceding paragraph sets forth the exclusive remedies for claims based on defect in or failure of products or services whether the claim is in contract indemnity warranty tort including Seller s negligence strict liability or otherwise and however instituted Upon the expiration of the warranty period all such li...

Page 9: ...blication library To access the library go to our website at the following location http www interlogix com transmission1 Sales and support contact information North America Toll free 855 286 8889 in the US including Alaska and Hawaii Puerto Rico Canada Outside the toll free area 503 885 5700 E mail techsupport interlogix com Europe Select Contact Us at www utcfssecurityproducts eu Australia secur...

Page 10: ...and remove securement screws for printed circuit board 4 If there are multiple boards to the assembly continue removing securement screws until none are left 5 Lift off printed circuit board 6 Disassembly of box version of product is complete For rack version 1 Locate and remove securement screws for printed circuit board Usually but not limited to at least 4 screws 2 If there are multiple boards ...

Page 11: ...erference in which case the user may be required to take adequate measures Canada This Class A digital apparatus complies with Canadian ICES 003 Cet appareil numérique de la classe A est conforme à la norme NMB 003 du Canada European Union directives 2004 108 EC EMC directive Hereby UTC Fire Security declares that this device is in compliance with the essential requirements and other relevant prov...

Reviews: