Product summary 

The SuperBus 2000® Phone Interface/Voice (PIV) Module 

provides phone and voice functions for the Concord™ , 

Concord 4™, and Concord Express™ (v4) panels. 

The PIV module allows installers and users to control a panel 

— either on-site or from a remote location — through any 

touch-tone telephone. Using an onboard digital voice chip, the 

system announces status messages through each phone and 

speaker connected to the module.  

The PIV module also provides phone control for Concord 

panels with single or multiple partitions. For multiple partitions, 

a module can be used for each partition and connected to a 

separate phone line.  

The module communicates with the panel through a series of 

bus connections and may be powered by the panel or an 

auxiliary 12V DC power supply with backup battery. 

SuperBus 2000 vs. SuperBus 

SuperBus 2000 panels auto-address module unit numbers. 

When the panel is powered, a unique device ID number (pre-

programmed at the factory) is automatically learned by the 

panel. Potential identical unit number conflicts and the need to 

manually set DIP switches are eliminated.  

Older SuperBus panels can communicate with the PIV module 

by manually setting the module’s DIP switches.  

SuperBus 2000 Panels  

• 

Concord (v2.0-later)  

• 

Concord 4  

• 

Concord Express (v4)  

SuperBus Panels  

• Concord 

(v1.0-1.6) 

Features 

The PIV module includes the following features:  

• 

User-adjustable, speaker volume control.  

• 

On/Off hook detection.  

• 

Extensive 220-plus word vocabulary.  

• 

In-panel cabinet or optional wall mounting.  

• 

Compatibility with Concord panels (v1.0-1.6). 

Figure 1: PIV module components 

     

   

         

   

   

 

 

      

         

    

 

 

            

      

 

 

             

   

 

   

       

   

   

       

      

 

   

 

     

    

      

 

      

 

 

 

    

 

 

 

       

Unit Number

DIP Switch

SuperBus 2000
Device ID Label

Wiring Terminals

Software Version

Label

Wire Access Areas

Status LED

 

Table 1: Module component descriptions 

Component Function 

Status LED 

Indicates normal panel bus communications.

Unit number DIP 
switches 

Used to manually set SuperBus unit 
numbers. 

Wiring terminals 

Provides panel, speaker, and phone 
connections. 

SuperBus 2000 device 
ID number label 

Identifies SuperBus 2000 device ID numbers.

Software version label 

Identifies installed module software versions.

Installation guidelines 

When installing the PIV module, use the following guidelines:  

P/N 466-1516-01 • REV C • 07APR11 

Summary of Contents for SuperBus 2000 PIV

Page 1: ...ically learned by the panel Potential identical unit number conflicts and the need to manually set DIP switches are eliminated Older SuperBus panels can communicate with the PIV module by manually setting the module s DIP switches SuperBus 2000 Panels Concord v2 0 later Concord 4 Concord Express v4 SuperBus Panels Concord v1 0 1 6 Features The PIV module includes the following features User adjust...

Page 2: ...d Four conductor 22 gauge or larger stranded wire RJ 31X Phone Jack not included DB 8 Cord included with Concord cabinet Support standoffs included with Concord cabinet Installation When installing the PIV module mount the module inside a panel cabinet or on a wall Caution To prevent damage to the panel or module remove the panel s AC power transformer and disconnect the backup battery before inst...

Page 3: ...ollowing guidelines prior to installing an RJ 31X phone jack Do not mount an RJ 31X jack CA 38A in Canada more than five feet away from the panel Connect the panel to a standard analog phone line Ensure the analog line provides 48V DC and can increase from 89V to 130V DC while the line is in use Note Concord panels cannot be used on a digital or PBX phone line These line types are designed only fo...

Page 4: ...ct the backup battery prior to wiring Wiring Power and Bus All partitions Figure 7 Wiring the PIV module to panel power and Bus terminals Panel Terminals Phone Interface Voice Module Terminal Strip 1 Phone Interface Voice Module Terminal Strip 2 Wiring phone line Note All partitions must be wired to separate phone lines Partition 1 Figure 8 Wiring the PIV module to a phone line partition 1 Phone I...

Page 5: ...ned to Partition 2 Note Because unit numbers for Concord RF receivers are factory set to 15 do not use this unit number setting Setting DIP Switches On the module locate the DIP switches see Figure 1 on page 1 Next set the desired unit number from 0 to 15 see Figure 12 below before you turn the power on Note DIP switches 1 4 are not used and must be set to OFF Figure 12 Unit number DIP switch sett...

Page 6: ...f the LED remains off replace the module The status LED remains lit but does not flash 1 Verify the panel recognizes the module see panel Installation Instructions 2 Check for proper wiring connections 3 If the LED fails to flash replace the module The module has a random inconsistent behavior 1 Check for proper wiring connections 2 Verify the panel recognizes the module see panel Installation Ins...

Page 7: ... to separate outlets on different branch circuits Consult the dealer or an experienced radio TV technician for help FCC Part 68 This equipment complies with part 68 of the FCC Rules Located on this equipment is a label that contains among other information the FCC registration number and the ringer equivalence number REN for this equipment If requested this information must be provided to the tele...