background image

2 / 6 

 

P/N 466-5401 

• REV B • 9MAY18   

Installation 

Use the following procedure to install the ShatterPro. 

1.  Choose a mounting location. Since the sound of 

breaking glass travels straight out from the broken 

window, the best location for mounting the sensor is the 

wall opposite the window--assuming the glass to be 

protected is within the sensor range and line of sight. 

The ceiling and adjoining (side) walls are also good 

sensor locations. A ceiling mounted sensor will have 

better detection if located 6' - 10' (2 m - 3 m) back from 

the glass rather than directly above the glass. 

IMPORTANT:   DO NOT EXCEED THE 20' MAXIMUM 

DETECTION RANGE OF THE 

SHATTERPRO.

 While the sensor may 

function beyond the 20' range it could miss a 

minimum output glassbreak. Furthermore, 

changing conditions in the room, such as 

rearranging furniture, could reduce the range 

of the sensor back to 20'. 

2.  Remove the cover from the ShatterPro base. Hold the 

base against the wall or ceiling at the desired mounting 

location. Insert screws through the two mounting holes 

in the base to attach it to the mounting surface. 

Caution: 

You must be free of static electricity before 

handling the transmitter circuit board. Touch a 

grounded, bare metal surface before touching the 

circuit board, or wear a grounding strap. 

Figure 3: 

Mounting holes (back view of ShatterPro) 

 

3.  Insert two 3 V batteries as shown in Figure 4 and 

replace the cover. 

4.  Use the procedures in the following sections; 

“Testing 

the ShatterPro

” and “Testing the System” on page 3 to 

make sure the sensor is working properly with the panel. 

Figure 4: 

Battery Installation 

 

Testing the ShatterPro 

Pattern Recognition Technology™ of the ShatterPro ignores 
most false alarm sounds, including glassbreak testers, so 
the ShatterPro must be set to “test mode” during the 
following procedure (see step 2). When the sensor is in test 

mode, processing of the glassbreak pattern in the upper and 

lower frequencies is disabled. The ShatterPro is then 

listening only for the mid-range frequencies, which the tester 

reproduces. It is these frequencies that determine the sensor 

detection range. 

Figure 5: 

Testing the ShatterPro 

 

The ShatterPro is designed to detect the breaking of framed 

glass mounted in an outside wall. Testing the sensor with 

unframed glass, such as broken bottles etc. may not trip the 

sensor. Use the hand-held tester and the following 

procedure to test the ShatterPro. 

1. 

Set the tester to “tempered glass.” 
The hand-held tester has a different setting for each 

type of glass. You should always set the tester for 

tempered or laminated glass (either is correct and both 

have the same range) unless you are certain that all the 

glass to be protected is plate glass. 

Summary of Contents for ShatterPro

Page 1: ...de Do not use sensor near air compressors A blast of compressed air may cause a false alarm Avoid stairwells glass booths and all rooms smaller than 10 x 10 3 m x 3 m The Pattern Recognition Technology of the ShatterPro ignores most false alarm sounds Some sounds can duplicate the glass break pattern the ShatterPro detects however so the ShatterPro works best in rooms with only moderate noise Avoi...

Page 2: ... board or wear a grounding strap Figure 3 Mounting holes back view of ShatterPro 3 Insert two 3 V batteries as shown in Figure 4 and replace the cover 4 Use the procedures in the following sections Testing the ShatterPro and Testing the System on page 3 to make sure the sensor is working properly with the panel Figure 4 Battery Installation Testing the ShatterPro Pattern Recognition Technology of ...

Page 3: ...y to achieve complete coverage 5 The sensor will automatically exit test mode if it does not sense any signals for 1 minute The Hand Clap Test You can test the ShatterPro without enabling the test mode by clapping your hands loudly under the sensor This sound will not trip the alarm but the sensor LED will blink twice This is a signal that the sensor has power and that the microphone and circuit b...

Page 4: ...erage Batteries 2 Duracell DL 123A 3V Lithium Transmitter Frequency 319 5 MHz Transmitter Conditions Alarm Tamper Low Battery Supervisory Microphone Omnidirectional electret Operating Temperature Range 32 to 120 F 0 to 50 C Storage Temperature Range 30 to 140 F 34 to 60 C Max Humidity 90 Relative Humidity non condensing Recommended glass Size Minimum 1 x 2 0 3 m x 0 6 m or larger Glass thickness P...

Page 5: ...device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Cet appareil est conforme avec Industrie Canada exempts de licence standard RSS s Son fonctionnement est soumis aux deux conditions suivantes 1 cet appareil ne doit pas provoquer d interférences et 2 cet appareil doit accepter toute interférence y...

Page 6: ...FOR INACCURACIES OR OMISSIONS AND SPECIFICALLY DISCLAIMS ANY LIABILITIES LOSSES OR RISKS PERSONAL OR OTHERWISE INCURRED AS A CONSEQUENCE DIRECTLY OR INDIRECTLY OF THE USE OR APPLICATION OF ANY OF THE CONTENTS OF THIS DOCUMENT FOR THE LATEST DOCUMENTATION CONTACT YOUR LOCAL SUPPLIER OR VISIT US ONLINE AT WWW INTERLOGIX COM THIS PUBLICATION MAY CONTAIN EXAMPLES OF SCREEN CAPTURES AND REPORTS USED IN...