International ShatterPro Glassbreak Sensor 
Installation Sheet 

Product summary 

The Interlogix International ShatterPro

®

 omnidirectional 

glassbreak sensor (60-873-43-EUR) provides 360 degree 

coverage. It can be mounted on the ceiling, the opposite wall, 

or on adjoining walls. It has a range of up to 6 m for glass 

panes 0.3 m x 0.6 m or larger. 

 

Figure 1: ShatterPro Glassbreak Sensor 

 

Figure 2: Sensor front and side views 

 

The maximum detection range is 6 m for plate, tempered, 

laminated, and wired glass. For armor-coated glass, the 

maximum detection range is 3.65 m. Coverage is measured 

from the sensor to the point on the glass farthest from the 

sensor (see D in Figure 3 below). See Specifications on page 3 

for recommended glass thickness. 

Figure 3: Optimum performance zone 

 

Note

: ShatterPro may not consistently detect cracks in glass, 

or bullets that break through the glass. Glassbreak sensors 

should always be backed up by interior protection. 

Installation guidelines 

• 

For best detection, avoid installing in rooms with lined, 

insulated, or sound deadening drapes or rooms with 

closed wooden window shutters inside. 

• 

Don’t use near an air compressor. A blast of air may 
cause a false alarm. 

• 

Avoid stairwells, glass booths, and all rooms smaller than 

3 m x 3 m. 

• 

The Pattern Recognition Technology™ of the ShatterPro 
ignores most false alarm sounds. Some sounds can 

duplicate the glassbreak pattern the ShatterPro detects, 

however, so the ShatterPro works best in rooms with only 

moderate noise. Avoid rooms where white noise, such as 

a fan is present. Avoid rooms with noisy areas or multiple 

noise sources such as small kitchens, bathrooms, or 

garages, etc. 

Note

: For glassbreak detection in these applications 

(where ShatterPro is not appropriate) use shock sensors 

on the windows or window frames. 

• 

Avoid adding (learning) the sensor into 24-hour sensor 

groups, where the sensor will be armed even when the 

room is in use. Like a motion detector, a glassbreak 

sensor may be tripped when occupants are in the 

protected area. Adding the ShatterPro to a perimeter 

group, which is armed only when the perimeter doors and 

windows are armed, will help prevent false alarms. 

• 

Do not install in humid rooms. The ShatterPro is not 

hermetically sealed. Excess moisture on the circuit board 

can eventually cause an electrical short and possibly a 

false alarm. 

• 

The sensor can be mounted as close as 1 m from the 

glass. 

 

  4.25in

10.8cm

 

  3.12in

7.9cm

Summary of Contents for ShatterPro 60-873-43-EUR

Page 1: ... rooms with closed wooden window shutters inside Don t use near an air compressor A blast of air may cause a false alarm Avoid stairwells glass booths and all rooms smaller than 3 m x 3 m The Pattern Recognition Technology of the ShatterPro ignores most false alarm sounds Some sounds can duplicate the glassbreak pattern the ShatterPro detects however so the ShatterPro works best in rooms with only...

Page 2: ...Testing the ShatterPro below and Testing the system on page 3 to make sure the sensor is working properly with the panel Figure 4 Mounting holes back view of the ShatterPro Figure 5 Battery installation Testing the ShatterPro Pattern Recognition Technology of the ShatterPro ignores most false alarm sounds including glassbreak testers so the ShatterPro must be set to test mode during the following ...

Page 3: ...EARN SENSORS menu 3 Select the appropriate sensor group or sensor number 4 Trip the tamper switch on the sensor 5 Repeat the above steps until all the sensors are added learned into the panel 6 Exit Program mode Testing the system The following steps describe general guidelines for testing the sensor Refer to your panel documentation for complete details 1 Set the panel to the Dealer Sensor Test m...

Page 4: ...ityproducts eu recycle This product may contain a battery that cannot be disposed of as unsorted municipal waste in the European Union See the product documentation for specific battery information The battery is marked with this symbol which may include lettering to indicate cadmium Cd lead Pb or mercury Hg For proper recycling return the battery to your supplier or to a designated collection poi...

Reviews: