NS3562-8P-2S Industrial Wall-mount Managed Gigabit Ethernet Switch Quick Installation Guide 

 

Figure 2: DC Power Input 

 

V+ = Positive / V- = Negative / Ground 

3.1 Terminal Block Connector Pinout 

To install the 3-pin Terminal Block Connector on the 
Wall-mount Managed Switch, follow these steps: 

Step 1: 

Insert positive DC power wire into 

V+

, negative 

DC power wire into 

V-

, and grounding wire into 

Ground. 

 

Step 2:

 Tighten the wire-clamp screws for preventing the 

wires from loosening and plug into the Wall-mount 
Managed switch  

Note

:  

1. 

The wire gauge should be in the range from 12 
to 24 AWG. 

2. 

The device must be grounded. 

4. Installation 

4.1 Wall Mount Installation 

To install the Wall-mount Managed Switch on the wall, 
follow these steps: 

Step 1: 

There are 4 holes with 8 mm diameter on the 

wall; the distance between the 2 holes is 133 mm 
and the line through them must be horizontal.

 

Step 2: 

Install a conductor pipe inside the board hole 

and flush the edge of the conductor pipe with the 
wall surface. 

Step 3: 

Screw the bolts into the conductor pipe. The 

Wall-mount Managed Switch is between bolts and 
conductor pipe, as shown below

Figure 3:  Wall Mount install 

 

4.3 DIN-rail Mount Installation 

The DIN-rail kit is included in the package. When the 
wall-mount application for the Wall-mount Managed 
Switch needs to be replaced with DIN-rail application, 
please refer to the following figures to screw the DIN-rail 
on the Wall-mount Managed Switch. To hang up the 
Wall-mount Managed Switch, follow the steps below: 

Step 1

: Screw the DIN-rail on the Wall-mount Managed 

Switch. 

Figure 4:  DIN Rail install 

 

Step 2

: Lightly insert the button of DIN-rail into the track. 

 

Step 3

: Check whether the DIN-rail is tightly on the 

track. 

Summary of Contents for NS3562-8P-2S

Page 1: ...If any item is found missing or damaged please contact your local reseller for replacement 2 Requirements Workstations running Windows XP 2003 Vista 7 8 2008 10 MAC OS X or later Linux UNIX or other platforms are compatible with TCP IP protocols Workstations are installed with Ethernet NIC Network Interface Card Ethernet Port Connection Network cables Use standard network UTP cables with RJ45 conn...

Page 2: ... with 8 mm diameter on the wall the distance between the 2 holes is 133 mm and the line through them must be horizontal Step 2 Install a conductor pipe inside the board hole and flush the edge of the conductor pipe with the wall surface Step 3 Screw the bolts into the conductor pipe The Wall mount Managed Switch is between bolts and conductor pipe as shown below Figure 3 Wall Mount install 4 3 DIN...

Page 3: ...please enter admin in both the default user name and password fields The login screen in Figure 6 appears Default Username admin Default Password admin Figure 6 Web Login Screen 3 After entering the password the main screen as shown in Figure 7 Note The following web screen is based on the WGS 4215 8T2S The display of the WGS 4215 8T2S is the same as those of the WGS 804HPT and WGS 4215 8T WGS 421...

Page 4: ...lt value press the reset button on the front panel for about 5 seconds After the device is rebooted you can login the Web interface management within the same subnet of 192 168 0 xx Figure 9 NS3562 8P 2S Reset Button 8 Customer Support Thank you for purchasing IFS products You can browse our online FAQ resource and User s Manual on IFS Web site first to check if it could solve your issue If you ne...

Reviews: