Interlogix MC251-4P/1S User Manual Download Page 2

ii                                                              IFS MC251-4P/1S and NS2051-4P/1T User Manual 

Copyright

 

© 2013  UTC Fire & Security Americas Corporation, Inc.  

Interlogix is part of UTC Climate Controls & Security, a unit of 
United Technologies Corporation.  All rights reserved. 

Trademarks and

patents

 

The IFS MC251-4P/1S and NS2051-4P/1T and logo are 
trademarks of United Technologies. 
Other trade names used in this document may be trademarks or 
registered trademarks of the manufacturers or vendors of the 
respective products. 

Intended use

 

Use this product only for the purpose it was designed for; refer to 
the data sheet and user documentation for details. For the latest 
product information, contact your local supplier or visit us online 
at www.interlogix.com. 

Manufacturer

 

UTC Fire & Security Americas Corporation, Inc.  
2955 Red Hill Avenue 
Costa Mesa, CA 92626-5923, USA  
EU authorized manufacturing representative: 
UTC Fire & Security B.V., Kelvinstraat 7,  
6003 DH Weert, The Netherlands 

Certification

 

 

 N4131 

FCC compliance

 

This equipment has been tested and found to comply with the 
limits for a Class A digital device, pursuant to part 15 of the FCC 
Rules. These limits are designed to provide reasonable 
protection against harmful interference when the equipment is 
operated in a commercial environment. This equipment 
generates, uses, and can radiate radio frequency energy and, if 
not installed and used in accordance with the instruction manual, 
may cause harmful interference to radio communications. 
You are cautioned that any changes or modifications not 
expressly approved by the party responsible for compliance 
could void the user's authority to operate the equipment. 

ACMA compliance 

Notice!

 This is a Class A product. In a domestic environment 

this product may cause radio interference in which case the user 
may be required to take adequate measures. 

Canada 

This Class A digital apparatus complies with Canadian ICES-
003.Cet appareil numérique de la classe A est conforme á la 
norme NMB-003du Canada. 

European Union 

directives

 2004/108/EC 

(EMC 

Directive): 

Hereby, UTC Fire & Security 

Americas Corporation, Inc. declares that this device is in 
compliance with the essential requirements and other relevant 
provisions of Directive 2004/108/EC.

 

 

 

 2002/96/EC 

(WEEE 

directive): 

Products marked with this 

symbol cannot be disposed of as unsorted municipal waste in 
the European Union. For proper recycling, return this product to 
your local supplier upon the purchase of equivalent new 
equipment, or dispose of it at designated collection points. For 
more information see: www.recyclethis.info.

 

Contact information

 

For contact information see our Web site: www.interlogix.com. 

Contact support

 www.interlogix.com/customer 

support 

 

 
 

Summary of Contents for MC251-4P/1S

Page 1: ...IFS MC251 4P 1S and NS2051 4P 1T User Manual P N 1072572 REV 00 06 ISS 30JAN13...

Page 2: ...ercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio...

Page 3: ...tallation 4 Product Description 4 Front Panel 5 LED Indicators 6 Top Panel 7 Wiring the Power Inputs 7 Wiring the Fault Alarm Contact 8 Mounting Installation 9 Application 13 Installation Steps 13 Swi...

Page 4: ......

Page 5: ...ver Ethernet Media converters also supports IEEE 802 3x flow control and back pressure standard in half duplex to eliminate packet loss Package Contents Check the contents of your package for the foll...

Page 6: ...Auto detect powered device PD Circuit protection prevent power interference between ports Remote power feeding up to 100m Layer 2 Features Complies with IEEE 802 3 10Base T IEEE 802 3u 100Base TX 100B...

Page 7: ...n IP 30 Aluminum Metal case Protection DIN Rail and Wall Mount Design Redundant Power Design 24 or 48V DC redundant power with polarity reverse protect function Supports EFT protection 6000V DC for po...

Page 8: ...d allows to power 4 PoE compliant devices at distance of up to 100 meters through the 4 pair Cat 5 5e UTP wire With Data and Power over Ethernet from one unit the MC251 4P 1S and the NS2051 4P 1T redu...

Page 9: ...ial straight or crossover cables The Flow Control function allows Industrial Fast Ethernet Switch supported routers and servers to directly connect to this device for fast reliable data transfer Front...

Page 10: ...ough that port is successfully established at 100Mbps Link ACT Green Blink Indicates that the Switch is actively sending or receiving data over that port Per 100Base FX Port LED Color Function Light I...

Page 11: ...er Inputs The 6 contact terminal block connector on the top panel of the MC251 4P 1S and the NS2051 4P 1T is used for two DC redundant powers inputs Please follow the steps below to insert the power w...

Page 12: ...dle of the terminal block connector as the picture shows below Inserting the wires the MC251 4P 1S and the NS2051 4P 1T will detect the fault status of the power failure and then forms an open circuit...

Page 13: ...ions to it Please read the following sections and perform the procedures in the order presented Note In the installation steps below this Manual uses the IFS GE DSGH 8 Industrial Gigabit Switch as an...

Page 14: ...ly press down and push the bottom of the DIN Rail connector mount into the track 2 Check that the DIN Rail connector mount is tightly mounted on the track 3 Please refer to following procedures to rem...

Page 15: ...nd pull the bottom of DIN Rail connector mount to remove it from the track Mounting to a Wall To install the MC251 4P 1S and the NS2051 4P 1T on the wall please follows the instructions described belo...

Page 16: ...ll mount plate on the rear panel of the MC251 4P 1S and the NS2051 4P 1T 3 Assemble the wall mount plate on the MC251 4P 1S and the NS2051 4P 1T 4 Use the hook holes at the corners of the wall mount p...

Page 17: ...terfaces the Industrial Fast Ethernet Switch can easily power a central controlled IP phone system IP camera system or AP group for the enterprise Installation Steps Step 1 Unpack the Industrial Fast...

Page 18: ...trial Fast Ethernet Switch Ethernet port RJ 45 port and the other side to the network device Ethernet port RJ 45 port ex Switch PC or Server The UTP port RJ 45 LED on the Industrial Fast Ethernet Swit...

Page 19: ...kup the address table for the destination address If not found this packet will be forwarded to all the other ports except the port which this packet came in And these ports will transmit this packet...

Page 20: ...ndustrial Fast Ethernet Switch the source address and corresponding port number of each incoming and outgoing packet are stored in a routing table This information is subsequently used to filter packe...

Page 21: ...by default and if the partner is set to half duplex then the performance will become bad Link LED is illuminated but the traffic is irregular Solution Check that the attached device is not set to ded...

Page 22: ...C Installation DIN Rail Kit and Wall Mount Ear Power over Ethernet PoE Standard IEEE 802 3af Power over Ethernet PSE PoE Power Supply Type End Span PoE Power Output 48V DC Per Port 350mA Max 15 4 Watt...

Page 23: ...ee C Storage 40 to 85 Degree C Humidity Operating 5 90 Storage 5 90 Non condensing Regulation Compliance FCC Part 15 Class A CE Stability testing IEC60068 2 32 Free Fall IEC60068 2 27 Shock IEC60068 2...

Page 24: ...10 100Base TX Cat 3 4 5 5e 6 UTP cable 100meters max 2 EIA TIA 568 100 ohm STP 100meters max 3 50 125 m or 62 5 125 m multi mode 9 125 m single mode cable Vary on SFP Module Standards Conformance Sta...

Page 25: ...ents 10 100Mbps 10 100Base TX RJ 45 Connector pin assignment Contact MDI Media Dependant Interface MDI X Media Dependant Interface Cross 1 Tx transmit Rx receive 2 Tx transmit Rx receive 3 Rx receive...

Page 26: ...22 IFS MC251 4P 1S and NS2051 4P 1T User Manual Please make sure your connected cables are with same pin assignment and color as above picture before deploying the cables into your network...

Page 27: ...allation Please make sure you have the requested diagnostic or log files ready before you contact us by phone or go to www interlogix com customer support Technical Support Europe Middle East and Afri...

Reviews: