background image

Calibur Kalatel KA2 ProBridge           1                            0150-0217B 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Calibur Kalatel KA2 ProBridge 

Product Overview 

& Installation Manual

 

Summary of Contents for Kalatel CBR-PB2-KA2

Page 1: ...Calibur Kalatel KA2 ProBridge 1 0150 0217B Calibur Kalatel KA2 ProBridge Product Overview Installation Manual ...

Page 2: ...ting device pursuant to subpart J of part 15 of FCC rules which are designed to provide reasonable protection against such interference when operated in a commercial environment This equipment has also been tested and found to comply with the requirements for a CE Class A device and TUV safety standards Operation of this equipment in a residential area may cause interference in which case the user...

Page 3: ...nment 4 1 4 Power 5 1 5 Installation Steps Summary 6 1 6 Connection Diagrams 7 2 Cable Specifications 8 3 Troubleshooting 9 4 Unit Settings 10 4 1 Configuring ProBridge Jumpers 10 5 Specifications 12 6 Appendix 13 6 1 RS 485 Addressing and Connections 13 7 Using Calibur Keypads 16 8 Warranty and Service 17 8 1 Factory Service 17 8 2 Warranty 17 ...

Page 4: ...twork support Kalatel Components 1 CBR PB2 KA2 ProBridge This product includes 1 CBR PB2 KA2 ProBridge unit 1 P N 4310 0034 RJ45 to RJ45 cable Connects the ProBridge to RS 485 Network This cable is 6 in length 1 P N 4310 0032A Cable from PB2 to Receiver Dome 1 P N 4010 0007 12VDC 120VAC Power Supply or 1 P N 4010 0008 12VDC 220VAC Power Supply 1 P N 0150 0217A Product Overview and Installation Man...

Page 5: ...mplete and all connections are made before applying power to the unit 4310 0007 120VAC Power Supply Power Supply Input Voltage 120 Volt AC Tolerance 10 Frequency 60 Hz Power Supply Output Voltage 12 Volt DC Current 110mA Power 1 3 Watts Connector 2 1mm female barrel Center Positive 4310 0008 220VAC Power Supply Power Supply Input Voltage 220 Volt AC Tolerance 10 Frequency 50 Hz Power Supply Output...

Page 6: ...the Calibur unit Multiplexer DVMRe Triplex via RS 485 port using the RJ 45 to RJ 45 cable The maximum total distance allowed on the RS 485 data line without signal amplification or modems is 3 000 feet 1 000 meters A 100 ohm terminator is required at each end of the RS 485 line 2 Supply power to the Calibur unit first and the CBR PB2 KA2 second using the supplied AC to 12 VDC adapter Via the Setup...

Page 7: ...latel CyberDome Kalatel Interface Connector Card Verify connections for the specific multiplexer used MUX DVMR RCVR DVR If remote PTZ control over Ethernet is to be provided with DVMRe Multiplexed Digital Recorder one CBR PB2 PTZ ProBridge unit is required in addition to the CBR PB2 KA2 unit referenced within this document If remote PTZ control over Ethernet is to be provided with a DVMRe Triplex ...

Page 8: ...range Pin 1 Orange White Pin 8 Brown Pin 7 Brown White Pin 6 Green Pin 5 Blue White Pin 4 Blue Pin 3 Green White Pin 2 Orange Pin 1 Orange White Do Not Connect Do Not Connect RJ 45 RJ45 Connector Connector RJ 45 Connector RJ 45 Connector ProBridge Unit to Dome PTZ Receiver RS 485 Part Number 4310 0032A Cable Communication Type RS 485 Connector Type RJ45 Terminals Cable Required 6 Foot RJ45 to Flyi...

Page 9: ...oting If you are unable to verify control of the PTZ camera please do the following 1 Check that each device is properly powered 2 Check that all cables and cable connections are correct 3 If the interface still does not work correctly contact Tech Support ...

Page 10: ...the ProBridge unit face down Using a small Phillips screwdriver carefully remove the screws located near each corner of the unit Once the screws have been removed lift the cover to detach Identifying The Jumpers With the cover removed orient the unit as shown here There are two sets of configurable jumpers One set located on the left side of the board controls how the unit communicates JP2 JP3 JP4...

Page 11: ... Installed P6 Pin 2 Installed P6 Pin 3 Not Installed P6 Pin 4 Not Installed P6 Pin 5 Not Installed P6 Pin 6 Not Installed P6 Pin 7 Not Installed P6 Pin 8 Not Installed P6 Pin 9 Not Installed P6 Pin 10 Not Installed P6 Pin 11 Not Installed P6 Pin 12 See Bulleted items No Jumper Installed Straight Preset Mapping i e Preset 1 is Preset 01 on Dome Jumper Installed Offset Preset Mapping i e Preset1 is ...

Page 12: ...nual Color Light gray Environmental Temperature 0 to 40 C operating Relative Humidity 90 non condensing Electrical AC Power External AC power supply included Voltage Range 110 to 240 VAC 10 Current 200 mA DC Power DC jack positive center Power Supply Voltage 12 VDC Current 110 mA Power 1 3 W All specifications are subject to change without notice Kalatel believes that all specifications are correc...

Page 13: ...e RS 485 data line Consult the PTZ installation manual for specific instructions on setting these addresses The CBR PB2 KA2 can be used in conjunction with multiple Calibur units multiple Cyberdomes or Receiver Drivers with one or more keypads controlling the domes and the Calibur units Since the ProBridge unit is a terminated device care should be used when using this unit in a mixed application ...

Page 14: ...ibur have addresses of 32 to 63 and so forth The RS 485 network is a multi drop wiring configuration of maximum length 3 000 feet 1000 meters RJ 45 cable and RJ 45 connectors are used for most hookups see the installation connection diagram Some equipment manufactured by Kalatel may use flying leads terminal blocks or other types of connections Most units have looping RS 485 network connectors Eit...

Page 15: ...174 206 494 16 15 47 79 111 143 175 207 495 17 16 48 80 112 144 176 208 496 18 17 49 81 113 145 177 209 497 19 18 50 82 114 146 178 210 498 20 19 51 83 115 147 179 211 499 21 20 52 84 116 148 180 212 500 22 21 53 85 117 149 181 213 501 23 22 54 86 118 150 182 214 502 24 23 55 87 119 151 183 215 503 25 24 56 88 120 152 184 216 504 26 25 57 89 121 153 185 217 505 27 26 58 90 122 154 186 218 506 28 2...

Page 16: ...or the respective keyboard for setup and use with Kalatel PTZ units In some specific cases keyboards may be used in conjunction with the CBR PB2 KA2 units where multiple Calibur units are being controlled via one or more local Keyboard Available keyboards are only involved when an RS 485 is configured with CBR KB2 J CBR KB3 J and KTD 405 Keyboards Please contact Technical Support for additional in...

Page 17: ...In Oregon 541 754 9133 Fax 541 754 7162 24 hours a day For warranty information see the following page 7 2 Warranty Kalatel warrants all of its equipment for three years from the date of purchase This warranty covers any defects in materials and workmanship Equipment failures that are due to improper installation modification abuse or acts of nature will not be covered by this warranty The repair ...

Page 18: ...from our stock and receive the returned product in exchange The received equipment will be evaluated and the repair department will determine whether it is a warranty replacement If it is non warranty see our repair policy above for details The following guidelines will be used for all advance replacements Fewer than 45 days from purchase Kalatel will replace the product with new equipment From 45...