16                                                                                  IFS MCR200-1T/1CX User Manual 

packets of data. SNR measures the quality of a transmission 
channel over a network channel. The greater the ratio, the 
easier it is to identify and subsequently isolate and eliminate 
the source of noise. 

Generally speaking, the higher SNR value gets better line 
quality, but lower performance. 

 

Q8:

 What is band plan and what’s the effect? 

A8:

 VDSL2 defines multiple band plans and configuration 

modes (profiles) to allow asymmetric and symmetric services 
in the same binder (by designated frequency bands) for the 
transmission of upstream and downstream signals. The user 
has the ability to select a fixed band plan.  
 

Symmetric band plan provides better downstream 
performance while Asymmetric band plan provides better 
upstream performance. 

 

 

Summary of Contents for IFS MCR200-1T/1CX

Page 1: ...IFS MCR200 1T 1CX User Manual P N 1076520 REV A ISS 07FEB12...

Page 2: ...lass A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial enviro...

Page 3: ...Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union For proper recycling return this product to your local supplier upon the purchase of equivalen...

Page 4: ......

Page 5: ...ors 5 Rear Panel 5 Mode DIP Switch 6 CO CPE 6 Fast and Interleave mode 7 Band Plan 7 Target SNR Signal Noise Ratio Margin 7 DC Power Jack 8 Installation 9 Installing the MCR200 1T 1CX 9 MCR200 1T 1CX...

Page 6: ......

Page 7: ...criber Line 2 This technology offers the absolute fastest possible data transmission speeds over existing lines or coaxial cables without the need for rewiring The IFS MCR200 1T 1CX has a switching ar...

Page 8: ...etworks The cable specifications of the connection are listed as follows 10Base T Category 3 4 or 5 UTP 100Base TX Category 5 5e or 6 UTP Ethernet over VDSL2 Coaxial cable 50 or 75 ohm The following i...

Page 9: ...ric band plans for the transmission of Upstream and Downstream signals Complies with IEEE 802 3 IEEE 802 3u and IEEE 802 3x standards DMT Discrete Multi Tone line coding Half Duplex Back Pressure and...

Page 10: ...speed of the incoming connection automatically This section describes the hardware features of the MCR200 1T 1CX Front panel illustrations in this chapter describe the unit LED indicators Before conn...

Page 11: ...On Indicates the VDSL Bridge is running at CO mode CPE Green On Indicates the VDSL Bridge is running at CPE mode 10 100Base TX Port LED Color Function On Indicates that the port link is On Blinking In...

Page 12: ...isted pair without noise and cross talk DIP 1 DIP 2 DIP 3 DIP 4 Mode Channel Band Plan SNR OFF CO Interleave Symm 9dB ON default CPE Fast Asymm 6dB CO CPE CO Central Office the Master device mode usua...

Page 13: ...tion with a duration less than 250 s Interleaved mode has a maximum end to end latency of 10m sec Band Plan The user can switch the Band Plan either Symmetric or Asymmetric by their own While the Symm...

Page 14: ...ntact your local sales representative Note This device requires power to operate For continuous functionality of the device using an UPS Uninterrupted Power Supply is recommended to prevent data loss...

Page 15: ...on is 3 0 km 9842 ft with 50 ohm coaxial cable Changes in the cable quality would affect the maximum distance of a connection MCR200 1T 1CX LAN to LAN connection Two sets of the MCR200 1T 1CX should b...

Page 16: ...its power source 3 The power LED will illuminate 4 Connect the coaxial cable from another MCR200 1T 1CX to the BNC port of the MCR200 1T 1CX 5 The LNK LED will blink 6 Connect the Ethernet port to an...

Page 17: ...Router via regular Cat 5 5e or 6 cables Figure 5 Connecting Multiple PCs to an Ethernet LAN Note Please refer to your Ethernet device User s Manual for the device s set up information Chassis Install...

Page 18: ...are attached to the MCR R15 Chassis use suitable screws to securely attach the brackets to the EIA 19 rack 5 Proceed with the steps 4 and steps 5 of the Stand alone Installation on page 11 to connect...

Page 19: ...media converter rack chassis If you need assistance regarding the correct power supply please contact your local sales representative 2 5mm DC Receptacle 2 5mm 5V for each slot The MCR R 15 DC outputs...

Page 20: ...e other MCR200 1T 1CX with CPE mode when connecting them together SYMPTOM TP LED does not light after a cable is connected to the port CHECKPOINT Verify that you are using either Cat 5 5e or 6 cables...

Page 21: ...gradually flexibly and cost efficiently upgrade exiting xDSL infrastructure Q3 What is the recommended maximum distance between MCR200 1T 1CX media converters A3 3 kilometers Q4 What is the maximum d...

Page 22: ...better line quality but lower performance Q8 What is band plan and what s the effect A8 VDSL2 defines multiple band plans and configuration modes profiles to allow asymmetric and symmetric services in...

Page 23: ...e select Selectable fast and interleaved mode Selectable target Band Plan Selectable target SNR mode Encoding VDSL DMT ITU T G 993 1 VDSL ITU T G 997 1 ITU T G 993 2 VDSL2 Profile 17a Support One Powe...

Page 24: ...600m 45 36Mbps 1800m 40 29Mbps 2000m 27 26Mbps 2200m 23 24Mbps 2400m 22 21Mbps 2600m 20 18Mbps 2800m 18 15Mbps 3000m 17 13Mbps Power Requirement 5V DC 2A Operating Temperature 0 50 C Storage Temperatu...