background image

 

6 / 9 

 

P/N 1073625-EN 

• REV 

• ISS 17APR19

 

250 m at a 

speed of 10

 

Mbps

 

(switch selectable).

 

Connector 

Removable 6

-

pin terminal block:

  

Pin 1/2 for Power 1

 

Pin 3/4 for 

power 

fault alarm

 

Pin 5/6 for Power 2

 

Alarm 

One relay output for power failure. 

 

Alarm r

elay current carry ability: 1

 

A @ 24

 

V

AC 

Power 

r

equirement

 

12 to 48 

VDC, 7 A (max.)

 

Power 

Consumption/ 

Dissipation 

4.3 W

, 14.6 BTU (Standby without PoE function) 

at DC 12 

V power input

 

72.5 W

, 247.4 BTU (Full loading 

with PoE 

function)

 at DC 12 

V power input

 

5 W, 17 

BTU (Standby without PoE function) at 

DC 24 

V power input

 

103.9 W

, 354.5 BTU (Full loading 

with PoE 

function)

 at DC 24 

V power input

 

5.3 W

, 18.1 BTU (Standby without PoE function) 

at DC 48V power input

 

135.8 W

, 463.4 BTU (Full loading 

with PoE 

function)

 at DC 48 

V power input

 

Dimensions 

(W 

× D 

× H) 

50 × 85.1 × 135 mm 

Weight

  

598 g 

ESD protection

 

5 KV DC

 

Enclosure

 

IP40 metal case

 

Installation

 

DIN rail kit and wall

-

mount ear 

 

Power over Ethernet

 

PoE Standard

 

IEEE 802.3at

 Power over Ethernet 

Plus

 

/ PSE

 

PoE Power Supply 

Type

 

End-

Span

 

Power Pin 

Assignment 

1/2(+), 3/6(

-) 

PoE Power Output

 

54 VDC Per Port, Max. 

36 W 

PoE Power Budget

 

(max.)

 

60 

W @

 12 

V

DC 

input

 

90 

W @

 24 

V

DC 

input

 

120 

W @

 48 

V

DC 

input

 

Max. 

N

umber of 

Class 2 PDs 

Max. 

N

umber of 

Class 3 PDs 

Max. 

N

umber of 

Class 4 PDs 

Standards conformance 

Regulatory

 

compliance  

FCC Part 15 Class A, CE

 

Stability testing

 

IEC60068

-2-

32 (Free Fall)

 

IEC60068

-2-

27 (Shock)

 

IEC60068

-2-

6 (Vibration)

 

Standards 

Compliance  

IEEE

 

802.3 10BASE

-T 

IEEE 802.3u 100BASE

-TX 

IEEE 802.3ab Gigabit 1000BASE

-T  

IEEE 802.3z Gigabit SX/LX

 

IEEE

 

802.3x Flow Control and Back 

P

ressure

 

IEEE 802.3af Power over Ethernet

 

IEEE 802.3at Power over Ethernet Plus

 

Environment 

Temperature 

 

Operating: 

-40 to +75°C 

Storage: 

-40 to 85°C

 

Humidity

 

5% to 95

% (

non-condensing)

 

NS2052-4P-1T 

Hardware specifications  

Fast Ethernet 

Copper Ports

 

 

Five

 

10/100BASE

-

TX RJ45 auto

-

MDI/MDI

-X ports 

(Port

-1 to Port-5) 

PoE Inject

or Port 

Four

 ports 

with 802.3af/at PoE+ injector function

 

(Port

-1 to Port-4) 

Switch Architecture

 

Store

-and-

Forward 

 

Switch Fabric

 

Gbps

/non-

blocking

 

Switch 

Throughput@64

 

bytes

 

0.74 

Mpps @64 bytes

 

MAC 

Address 

Table 

 

2K entries  

Flow Control 

 

IEEE 802.3x 

p

ause frame for full

-d

uplex

 

Back pressure for 

h

alf

-d

uplex

 

Jumbo Frame

 

10 Kby

tes 

DIP Switch (Port

-1 

to Port-4) 

Standard mode: 

30 W PoE transmission distance 

of 

100 

m at speed of 10

/100 

Mbps

VLAN mode: 

"Port-

based VLAN Protection" where 

ports can be isolated from each other via one DIP 

switch. 

Only Port

-5 can visit other ports.  

E

xtend mode: 

25 W PoE transmission 

distance of 

250 m at a 

speed of 10

 

Mbps

 

(switch selectable).

 

Connector 

Removable 6

-

pin terminal block:

  

Pin 1/2 for Power 1

 

Pin 3/4 for 

power 

fault alarm

 

Pin 5/6 for Power 2

 

Alarm 

One relay output for power failure. 

 

Alarm r

elay current carry ability: 1

 

A @ 24

 

V

AC 

Power 

r

equirement

 

12 to 48 

VDC, 7 A (max.)

 

Power 

Consumption/ 

Dissipation 

3.7 W

, 12.6 BTU (Standby without PoE function) 

at DC 12 

V power input

 

70 W, 238.8 

BTU (Full loading 

with 

PoE function)

 

at DC 12 

V power input

 

4.6 W

, 15.7 BTU (Standby without PoE function) 

at DC 24 

V power input

 

105.1 W

, 358.6 BTU (Full loading 

with PoE 

function)

 at DC 24 

V power input

 

4.8 W

, 16.4 BTU (Standby without PoE function) 

at DC 48V power input

 

136.8 W

, 466.8 BTU (Full loading 

with PoE 

function)

 at DC 48 

V power input

 

Dimensions 

(W 

× D 

× H) 

50 × 85.1 × 135 mm 

Weight

  

596 g 

ESD protection

 

5 KV DC

 

Enclosure

 

IP40 metal case

 

Installation

 

DIN rail kit and wall

-

mount ear 

 

Summary of Contents for IFS MC252-4P-1S

Page 1: ...rt MC252 4P 1S One 100BASE FX SFP interface One terminal block for master and slave power input Power Range 12 48 VDC redundant power Hardware DIP switch for Standard VLAN and Extend mode selection the Extend mode features a 25 W PoE transmission distance of 250 m at a speed of 10 Mbps Port 1 to Port 4 only Power over Ethernet Complies with IEEE 802 3at Power over Ethernet Plus end span PSE Backwa...

Page 2: ...olarity 12 48 VDC power supply inputs for high availability applications Environmentally hardened design With the IP40 metal industrial case the industrial PoE switch provides a high level of immunity against electromagnetic interference and heavy electrical surges which are usually found on plant floors or in curb side traffic control cabinets without air conditioning It features a ventilated con...

Page 3: ...t 5 of NS2052 4P 1T LED Color Function Link ACT Green Lit indicates the port is successfully connecting to the network at 10 or 100 Mbps Blinking indicates that the port is actively sending or receiving data Per 100FX SFP Slot Port 5 of MC252 4P 1S LED Color Function Link ACT Green Lit indicates the port is successfully connecting to the network at 100 Mbps Blinking indicates that the port is acti...

Page 4: ...tors on the top and a minimum of three inches above and below the switch to allow for proper air flow This device uses a convection flow of hot air which rises and brings cold air in from the bottom and out of the top of the device Do not mount the switch horizontally as this does not allow air to flow up into the device and will result in damage to the switch Do not tie DC1 to DC2 DC2 is for seco...

Page 5: ...iber network TX RX must be paired at both ends The optical port LED on the MC252 4P 1S illuminates when the connection is established with a network device Please refer to the LED indicators section for LED definitions 8 When all connections are set up and the LEDs illuminate the installation is complete Troubleshooting This section contains issue solving information If the industrial PoE switch i...

Page 6: ... Power over Ethernet IEEE 802 3at Power over Ethernet Plus Environment Temperature Operating 40 to 75 C Storage 40 to 85 C Humidity 5 to 95 non condensing NS2052 4P 1T Hardware specifications Fast Ethernet Copper Ports Five 10 100BASE TX RJ45 auto MDI MDI X ports Port 1 to Port 5 PoE Injector Port Four ports with 802 3af at PoE injector function Port 1 to Port 4 Switch Architecture Store and Forwa...

Page 7: ...ressure IEEE 802 3af Power over Ethernet IEEE 802 3at Power over Ethernet Plus Environment Temperature Operating 40 to 75 C Storage 40 to 85 C Humidity 5 to 95 non condensing Appendix Networking connection RJ45 pin assignments 1000Mbps 1000BASE T Contact MDI MDI X 1 BI_DA BI_DB 2 BI_DA BI_DB 3 BI_DB BI_DA 4 BI_DC BI_DD 5 BI_DC BI_DD 6 BI_DB BI_DA 7 BI_DD BI_DC 8 BI_DD BI_DC 10 100Mbps 10 100BASE T...

Page 8: ...y information please check www firesecurityproducts com policy product warning or scan the following code Contact information and manuals tools firmware For contact information and to download the latest manuals tools and firmware go to the web site of your region Americas www interlogix com EMEA www firesecurityproducts com Manuals are available in several languages Australia New Zealand www utcf...

Page 9: ... Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union For proper recycling return this product to your local supplier upon the purchase of equivalent new equipment or dispose of it at designated collection points For more information see www recyclethis info Contact information North America T 1 855 286 8889 E techsupport interlogix com W www int...

Reviews: