Chapter 4: Menu reference
CDC4 Door Controller Installation and Programming Manual
103
See “IN reader options” on page 102 for details.
Other options
The following options are available.
Dual badge
If two-badge functionality is used, then enabling this option means that both
users are reported as having accessed a door. In addition, anti-passback rules
and region rules (including region count) will be applied to both users. If either
user fails for any reason, for example, passback, then the door will remain locked
and access will be denied when the failed user presents their card or PIN.
Disabling this option means that only the second user is reported as having
accessed a door. Thus if a visitor and an accompanying guard badge their cards
to open a door, only the guard is considered as having accessed the door.
Two badge unlock, one badge relock
As an alternative to two-badge, two badge unlock avoids unintended unlocking of
a door if a user accidentally presents their card to a reader, for example, by
brushing past the reader with the card in a pocket. When two badge unlock is
enabled (and the low security schedule is not valid), the user may unlock the
door by presenting the same card twice within the two-badge
time (see “Dual
Badge Time
” on page 99). If the low security schedule is valid, then the two
badge unlock setting is ignored (see the “Low Security Schedule” section on
page 101).
The door will remain unlocked until a user badges a card at the reader.
Note:
When two badge unlock is enabled and two different cards are presented
within the two-badge time (regardless of whether two-badge is used), then the
door is not unlocked and a door access denied message is generated.
OUT reader no schedule required
If selected, OUT readers will allow access even if a user door group does not
have a valid schedule.
Door unlocked until opened
For security reasons, it is possible for the door to re-lock at the moment it opens.
The door output will be deactivated after the door is opened. This option will
override the unlock time. The door will stay unlocked until opened.
When selected, after a door is unlocked by a card or PIN, the door lock output
will remain activated until the door input is active.
Door unlock after entry
This field determines whether the override schedule
(see the “Unlocked
” section on page 101) takes effect immediately the schedule
commences or after a user enters.
Summary of Contents for CDC4
Page 1: ...CDC4 Door Controller Installation and Programming Manual P N 466 5478 REV D ISS 29OCT19 ...
Page 86: ...Chapter 3 Programming 80 CDC4 Door Controller Installation and Programming Manual ...
Page 120: ...Chapter 4 Menu reference 114 CDC4 Door Controller Installation and Programming Manual ...
Page 136: ...130 CDC4 Door Controller Installation and Programming Manual ...