NX148-E AMERICAN SPANISH LIBRARY
ABAJO CONTACTO EXTERIOR
JARDIN PRINCIPAL
SOTANO
ALARMA CRISTAL
FACHADA
LABORATORIO
PUERTA TALLER
ALMACEN DESPACHO
FUEGO
LATERAL RECEPCION
TECHO
ARRIBA DETECTOR
GARAJE LAVABO RECIBIDOR
TERRAZA
AVERIA DISPARO
GERENCIA
MAGNETICO
SABOTAJE
TIENDA
AZOTEA DOBLE
TECHNOLOGIA
GOLPE OFICINA SALA
TRASERO
BARRERA DORMITORIO
HABITACION
PANICO
SALIDA
VALLA
CAJA FUERTE
EMERGENCIA
HUMO
PARED
SALON
VENTANA
CLARABOYA ENTRADA
INFORMATICA
PASILLO
SENSOR
VESTIBULO
COCINA ESTACIONAMIENTO
INFRARROJO
PERSIANA
SILENCIOSA
ZONA
COMEDOR ESTUDIO
INTERIOR PLANTA
SIRENA
LOADING FACTORY DEFAULTS
To load the factory defaults, enter the Program Mode for the module to be defaulted using the procedure on page 2,
then type [
9
]-[
1
]-[
0
]-[
#
]. The keypad will beep 3 times indicating that the loading is in progress. The loading takes about
6 seconds. To load the factory defaults for the LCD keypad, enter the Program Mode from a
different
keypad (does
not have to be LCD keypad), and follow the procedures mentioned previously.
NOTE: The two-line Custom and
two-line Shutdown Messages will not be defaulted.
ENROLLING MODULES AND KEYPADS
For supervision purposes, the NetworX control panel has the ability to automatically find and store in its memory the
presence of all keypads, zone expanders, wireless receivers, and any other module connected to the data terminal.
This allows these modules to be supervised by the control panel.
NOTE
: All modules should be connected and set to
unique addresses prior to enrolling modules. To enroll the modules, enter the Program Mode of the NetworX control
panel. When the Program Mode is exited, the control will enroll the devices. The enrolling process takes about 12
seconds, during which time the "Service Required" will be displayed. Once a module is enrolled, if it is not detected by
the control, the "Service Required
@
will be displayed.
PROGRAMMING THE NX148-E LCD KEYPADS
This section describes how to program the address and partition of each keypad, as well as the options that are
available. The address of the keypad is important because this is how the panel supervises the keypads. The factory
default for the “Master Code” is [
1
]-[
2
]-[
3
]-[
4
] when using a 4-digit code, or [
1
]-[
2
]-[
3
]-[
4
]-[
5
]-[
6
] for a 6-digit code. The
factory default for the "Go To Program" code is [
9
]-[
7
]-[
1
]-[
3
] when using a 4-digit code, or [
9
]-[
7
]-[
1
]-[
3
]-[
0
]-[
0
] for a 6-
digit code.
USING THE FUNCTION MENU
Many of the functions shown below are in the Function Menu. Press [
r
] to access this menu. Once the [
r
] key is
depressed, the display will begin scrolling though a list of functions and the corresponding number(s) associated with
those functions.
To access a function press the number(s) listed for that function. If you already know the function
numbers simply press [
r
] followed by the function number.
NOTE
: Some of the functions are not listed because they are installer-level functions.
These are samples of the displays that will appear in the Function
Menu. Each time the [
r
] key is pressed the next menu item will be
displayed. Press the number or key to access the function desired.
Press the [#] key to exit.
Select an Option
Press
✱
for Help
Select an Option
ù
=Zone Review
4