background image

Note

: A green light flashes each time a number or 

function button is pressed. A red and green light 
flash each time a panic button is pressed. 

1. 

Notify the central monitoring station that (1) 
you are testing the security system and (2) 
not to dispatch emergency services. 

Technical support, www.interlogix.com/customer-support 

www.utcfireandsecurity.com or www.interlogix.com 

Copyright © 2011 UTC Fire & Security Company. All rights reserved 

2. 

Arm and disarm the system with the 
touchpad from various locations in order to 
determine usable range. 

3. 

Press STATUS to check the current arming 
level. 

4. 

Select Direct and Indirect to bypass sensors. 

5. 

Press and hold each panic button 

until 

the 

red/green indicator light stops flashing and 
the appropriate alarm sounds. 

6. 

Turn lights on or off (see system 
documentation). 

7. 

Press and hold the buttons marked 

1

 and 

2

 

at the same time to mute the touchpad. 
Continue to hold the buttons until you hear a 
series of confirmation beeps. 

8. 

Press various buttons to test the mute 
feature. 

9. 

Press and hold the buttons marked 

1

 and

 2

 

at the same time to turn off the mute 
function. Continue to hold the buttons until 
you hear a series of confirmation beeps. 

10.  Contact the central monitoring station after 

you have finished testing the touchpad. 

Mounting the touchpad 

Test the wireless touchpad at a desired location. 
Ensure that a clear RF signal exists between the 
touchpad and control panel. After successfully 
testing for a clear RF signal, you can mount the 
touchpad as follows: 

1. 

Secure the touchpad mounting bracket to a 
desired surface. Use the screws from the 
accessory pack to mount the bracket (see 
Figure 3 below). 

Figure 3: Securing the mounting bracket 

Screws

Mounting 

Holes

 

2. 

Attach the touchpad to the mounting bracket 
by placing the touchpad bottom into the 

bracket bottom. Press the touchpad into 
place to ensure a secure fit (see Figure 4 
below). 

Figure 4: Attach to mounting bracket 

 

Specifications 

Model no. 

60-597 

RF frequency 

319.5 

Compatibility Concord, 

Concord 

Express, and Advent 
security panels 

Power requirements 

One 3.0 V DC lithium 
battery 

Battery life 

5 to 8 years 

Storage temperature 

-40° to 140°F (-34° to 
60°C) 

Operating 
Temperature 

10° to 120°F (-12° to 
49°C) 

Maximum Humidity 

90% relative humidity, 
non-condensing 

Dimensions 

2.1 x 0.86 x 6.1 in. (5.33 x 
2.18 x 15.5 cm) 

Regulatory information 

Manufacturer 

UTC Fire & Security Americas 
Corporation, Inc. 
1275 Red Fox Rd., Arden Hills, 
MN 55112-6943, USA 

FCC compliance:

 

This device complies with FCC Rules Part 15. 
Operation is subject to the following two 
conditions: 
1. This device may not cause harmful 
interference. 
2. This device must accept any interference that 
may be received, including interference that may 
cause undesired operation. 
Changes or modifications not expressly 
approved by Interlogix can void the user’s 
authority to operate the equipment. 
FCC ID No.: B4Z-861-HTTP 

 

Reviews: