Learn Mode Rate of Rise Heat Sensors Installation Instructions
3
Figure 3. Mounting holes
Replacing the batteries
When the sensor battery gets low, the sensor transmits a low
battery signal. The panel receives this signal and sounds
trouble beeps through the system sirens. Pressing the Status
button identifies the sensor with the low battery.
Replace the battery immediately when this condition occurs,
using the following batteries: Eveready
©
9-Volt Alkaline
Energizer (No. 522); Duracell
©
9-Volt Alkaline (MN1604); or
UltraLife
©
9-Volt Lithium.
Battery disposal
Alkaline and lithium batteries that are not longer usable are
considered hazardous waste. Be sure to properly dispose of
the old batteries according to your local hazardous waste
disposal laws.
Specifications
Compatibility
Interlogix Learn Mode panels and receivers
Frequency
319.5 MHz
Pow er requirements
One 9-volt alkaline or lithium battery
Operating temperature 60-460-95/NX495, 60-460-95-LB:
40 to 100°F (4 to 37°C)
60-460-01-95/NX-496:
32 to 150°F (0 to 66°C)
Storage temperature
60-460-95/NX-495, 60-460-95-LB:
-30 to 120°F (-34 to 48°C)
60-460-01-95/NX-496:
-30 to 140°F (-34 to 60°C)
Maximum humidity
90% relative humidity, noncondensing
Dimensions
4.4 in. (11.18 cm) diameter x 2.2 in. (5.59 cm)
depth
Regulatory information
Manufacturer
UTC Fire & Security Americas Corporation, Inc.
1275 Red Fox Rd., Arden Hills, MN 55112-6943,
USA
UL listings
UL 985 Household Fire Warning System Units
UL 521 Heat Detectors for Fire Protective
Signaling Systems
FCC compliance
This device complies w ith part 15 of the FCC
rules for Class A devices. Operation is subject to
the follow ing conditions:
This device may not cause harmful interference.
This device must accept any interference
received, including interference that may cause
undesired operation.
Changes or modifications not expressly approved
by the party responsible for compliance could
void the user’s authority to operate the
equipment.
FCC ID: B4Z-569A-LMRISE
Contact information
For contact information, see www.utcfireandsecurity.com or
www.interlogix.com.
For technical support, toll-free: 888.437.3287 in the US
including Alaska, Hawaii, Puerto Rico, and Canada. Outside
the tool-free area, contact your dealer.
© 2012 UTC Fire & Security Americas Corporation, Inc.
Interlogix is part of UTC Climate Controls & Security, a unit of
United Technologies Corporation.
All rights reserved.