ESL 500 Series

Specifications

Voltage

DIP switch 1 ON for standard 12V operation (6.5-20 VDC), polarity sensitive
DIP switch 1 OFF for standard 24V operation (8.5-33 VDC), polarity sensitive

Maximum ripple (pk to pk)

10% (V p-p)

Typical average standby current

70 uA (12/24V)

Typical alarm current (12/24V)

up to 60mA max. if not limited by control panel

Aux. relay contacts

2A @ 30VDC

Alarm contacts

500mA @ 36VDC (resistive)

Photoelectic sensitivity

3.1% + 0.5 - 1.0%

Operating termperature

32° to 100°F (0° to 37°C)

Operating humidity range

0 to 95% non-condensing

RFI immunity

20V/m minimum; 0-1000MHz

Color

white head and base

Field wiring size

12-24 AWG

Detector packaging

10 detectors per carton

Heat detector specifications

rate of rise - 15 F/min and >105 F (8.3 C/min and >40.6 C)

UL 2-wire compatibility identifier:

521/528 - DIP switch 1 ON

S09A

521/528 - DIP switch 1 OFF

S10A, S11A (RX models)

511/518

S10A

Drift compensation adjustment

1.0%/ft. max

Detector head dimensions

5 in. (12.7cm) diameter; 2 in. (5cm) height

Mounting dimensions

4.75 in. (12.1cm) diameter; 0.3 in. (0.8cm) height

Reset time

1 second minimum

Listings:

511/521/541

UL 268

518/528/548

ULC

1036205 Rev A 06/01

Product Ordering

Model

Description

511C/518C

2-wire, photoelectric, 6.5-33VDC

511AFT/518AFT

2-wire, photoelectric, 6.5-33VDC, rate of rise heat sensor

521B/528B

2-wire, photoelectric, 6.5-33VDC

521BXT/528BXT

2-wire, photoelectric, 8.5-33VDC, multi-criteria algorithms, fixed/rate of rise heat

521CRXT/528CRXT

2-wire, photoelectric, 8.5-33VDC, aux. relay, multi-criteria algorithms, fixed/rate of rise heat

541C/548C

4-wire, photoelectric, 8.5-33VDC

541CXT/548CXT

4-wire, photoelectric, 8.5-33VDC, multi-criteria algorithms, fixed/rate of rise heat

541AXT/548AXT

4-wire, photoelectric, 6-20VDC, multi-criteria algorithms, fixed/rate of rise heat

Accessories:

505

Module that interprets the 521/528 models CleanMe signal for panel and can convert 2-wire
521models to 4-wire inputs on the panel.

401

Test magnet in plastic shell for  pole mounting

SM-200

Smoke! in a can

®

 (canned smoke) for functional testing of smoke detectors

211

Replacement optical chambers (set of 10)

Summary of Contents for 511C

Page 1: ... DIP switch that allows the installer to choose between 12 24V operation and 6 12V operation See Figure 1 and Specifications Note Please refer to the ESL Compatibility Index for a complete listing of control panels and proper identifiers For a copy of the Compatibility Index call 1 800 648 7424 or visit www sentrol com for a copy to down load Remember 4 wire smoke detectors do not require a compat...

Page 2: ...t least 4 inches 10cm from any walls or partitions Locate wall mounted smoke detectors so the top of the detector is 4 to 12 inches 10 to 30cm below the ceiling Do not locate detectors in or near bathrooms or kitchens Locate in a suitable environment as follows Temperature between 32 F 0 C and 100 F 37 C Humidity between 0 and 95 non condensing Locate away from air conditioners heating registers a...

Page 3: ... ON 2 1 ON 2 Models with gaskets 521CRXT 528CRXT 541C 541CXT 541AXT 548C 548CXT 548 AXT Models without gaskets 511C 511AFT 518C 518AFT 521B 521BXT 528B 528BXT Figure 5 Detector installation ESL 204 12 24V Power Supervision Relay 541 548 Series 4 wire wiring diagram Figure 6 Wiring diagrams First Detector Last Detector EOL Resistor Model 541CXT 548CXT Model 541C 548C 541AXT 548AXT Power Listed Alar...

Page 4: ... must be reset from the control panel If the sensitivity is not within limits or an unserviceable hardware fault has been detected the detector LED flashes every 1 5 seconds until the detector is serviced Cleaning the Detector Clean the detector cover with a dry or damp water cloth as needed to keep it free from dust and dirt When necessary clean the detector interior and replace the optical chamb...

Page 5: ...rded to the customer suggesting a replacement unit and the cost of that unit This warranty does not apply to units which have been subject to abuse misuse negligence or accident or to which any modifications alterations or repairs have been made or attempted This warranty is extended only to the original purchaser of the smoke alarm and may be enforced only by such person During the warranty perio...

Page 6: ...nsions 5 in 12 7cm diameter 2 in 5cm height Mounting dimensions 4 75 in 12 1cm diameter 0 3 in 0 8cm height Reset time 1 second minimum Listings 511 521 541 UL 268 518 528 548 ULC 1036205 Rev A 06 01 Product Ordering Model Description 511C 518C 2 wire photoelectric 6 5 33VDC 511AFT 518AFT 2 wire photoelectric 6 5 33VDC rate of rise heat sensor 521B 528B 2 wire photoelectric 6 5 33VDC 521BXT 528BXT...