Interlevin ECF98 Instruction Manual Download Page 6

12

•  Pull the plug (as far as provided) out of the freezer bottom.

•  As previously described, scrape the thickest ice carefully 

from the freezer inside and put it into the kitchen sink. for 
defrosting.

•  If necessary, speed up defrosting by placing a large pot of 

warm (not too hot) water on the freezer bottom.

•  In freezers not provided with a drain-plug, continuously wipe 

up the water with a sponge.

•  Thoroughly clean the inside. Rinse it with a mixture of warm 

water and vinegar, thereafter rinse with clear water.

•  Wipe the freezer with an absorbent cloth thoroughly dry and 

allow to air for about 3 to 4 minutes.

•  Replace the drain-plug (if provided)

•  Empty the dry defrosting water dish (if provided) and slide it 

as separator into the guide rails of the freezer.

•  Close the chest and plug it back into the socket.

•  Now refill the frozen food – the oldest items at the top. To 

prevent frosted food from defrosting, carry out steps from 1 
to 17 within max. two hours.

•  When the red lamp goes off, reset the temperature control 

to a as per the filling capacity suitable storage temperature.

Resolving faults on your own

If you suspect any fault, before contacting the after-sales service 
directly or via your dealer, make sure you have observed all in-
structions and advice in this user manual.

Repairs  by  the  after-sales  service,  of  faults  that  have  occurred 
because of non-adherence to the information and advice given 
in this manual have to be charged to the customer and are not 
covered by your dealer’s guarantee.

Attention

The compressor (also known as motor) must not operate conti-
nuously.

It is controlled by the thermostat which you set with the tempe-
rature  control.  It  switches  on  automatically  when  the  set  tem-
perature in the storage compartment exceeds and switches off 
automatically when the correct temperature is reached again.

Noise can be heard in every compressor – cooling system when 
the compressor is switched on. This noise is produced when the 
motor in the compressor operates and also by refrigerant flowing 
in the cooling system circuit.

These noises are normal and do not indicate any functional trou-
ble.

In unheated rooms and in cold weather condition condensation 
can build up on the outer walls of the appliance. This does not 
mean trouble and disappears when the weather becomes war-
mer.

TROUBLE SHOOTING:

The  design  and  production  comply  with  the  relative  security 
standard of China. If you find

it does not work as usual, please examine and handle it accord-
ing to the following table first. If the situation does not improve, 
you must contact our after-sale service center.

Reviews: