27
4. Dispose of the battery according to the manufacturer’s instructions.
5. Install the expansion cards that you removed.
LEDs, Power, and Reset Switches
See the System Board Manual for connector and socket locations.
To replace the reset or power switches:
1. Open the face panel. See “Base Unit Components” for details.
2. Disconnect the switch cable connector from the system board.
3. Remove the two screws attaching the LED and switch mounting plate to the chassis.
4. Disconnect the power and LED cables from the switch mounting plate. Note the position
of the cables before you disconnect them.
5. Remove the switch button cover as shown in the following figure.
6. Insert the connector end of the switch cable through the cable access hole on the front of
the chassis and route the new switch cable through the chassis.
7. Connect the switch cable to the connector on the system board.
8. Press the switch into its mount on the switch plate and tighten.
9. Reconnect the power and LED cables to the appropriate LED or switch.
10. Replace the two screws attaching the mounting plate to the chassis.
11. Install the face panel and the power switch button.
LED Assembly
Power/Reset
Switch Assembly