2
(IBBS) or Intergraph’s File Transfer Protocol (FTP) site. A Portable Document Format (PDF) file for
the System Reference is now delivered in the
C
:\
WIN
32
APP
\
SYSREF
directory on your system’s primary
hard disk drive. You can use the Adobe Acrobat Reader to view and print this file. A copy of the
Adobe Acrobat Reader installer is also delivered in
C
:\
WIN
32
APP
\
SYSREF
; see the
README
.
TXT
file in
that directory for more information.
MegaRAID Controller Assignments
If you install additional RAID controllers in an InterServe 615, 625, 635, or 645 system, be aware that
the RAID controller scan order is not as described in the InterRAID documentation. The MegaRAID
BIOS Configuration utility and the MegaRAID Power Console program detect the presence of
MegaRAID controllers and assign the controller numbers in dissimilar ways. The assignments also
vary depending on the system’s boot device.
MegaRAID Controller is in PCI Slot 1
The following tables show how Power Console and BIOS Configuration list from one to four installed
MegaRAID controllers when the MegaRAID controller in PCI slot 1 is the boot device.
Number of
Controllers
PCI
Slot
Controller
Order
Power
Console
BIOS
Configuration
1
1
1st
0
0 (Boot)
2
1
1st
0
0 (Boot)
2
2nd
1
1
3
1
1st
0
0 (Boot)
2
2nd
1
2
3
3rd
2
1
4
1
1st
0
0 (Boot)
2
2nd
1
3
3
3rd
2
2
4
4th
3
1
Fixed Hard Disk Drive is the Boot Device
The following tables show how Power Console and BIOS Configuration list from one to four installed
MegaRAID controllers when a fixed hard disk drive (on a separate controller) is the boot device.
Number of
Controllers
PCI
Slot
Controller
Order
Power
Console
BIOS
Configuration
1
1
1st
0
0
2
1
1st
0
1
2
2nd
1
0
3
1
1st
0
2
2
2nd
1
1
3
3rd
2
0