WARRANTY CONDITIONS 

With due regard for the conditions indicated below, Intergas Heating 
Ltd warrants to the authorised installer the soundness of the 
materials used in and the correct operation of its Central Heating 
products, when used for the purpose for which they are delivered. 
As the occasion arises we should be enabled to ascertain, on site if 
necessary, the soundness of the warranty entitilement. 

The warranty comprises: 

The warranty is limited to the free-of-charge resupply of parts that 
during the warranty period, entirely in our judgement exhibit 
material or manufacturing faults that are not the result of normal 
wear etc. Such parts should be sent to us carriage paid together 
with an indication of the defect and after replacement become our 
property. 

1.

 

The warranty period on parts is 2 years calculated from the 
date of installation. The extended warranty period on parts is 3 
years calculated from the date of installation. The extended 
warranty is effective only if the annex to the warranty 
certificate has been signed by the purchaser and returned to 
us within 8 days of the date of installation.  

2.

 

The warranty period on the water tightness of the boiler’s heat 
exchanger is 10 years, provided however that if, as a result of 
corrosion, leakages arise which in our view cannot be rectified 
on site, we will exclusively supply that boiler part on the basis 
of old for new, calculated at the time of replacement from the 
installation date. 

3.

 

The warranty ceases to apply if it is ascertained that the 
defects, damage or excessive wear are attributable to 
improper use or injudicious treatment or inexpert repair, 
setting, installation or maintenance by unauthorised installers 
or to the product being exposed to substances containing 
aggressive chemicals (including hair lacquer) and other 
harmful substances. 

4.

 

The warranty also ceases to apply if pipes and couplings have 
been used in the installation which can cause oxygen 
diffusion, or if the defect is the result of depositing of boiler 
scale (harmful to the boiler and the installation). 
Surface damage and transport damage are not covered by the 
warranty. The right to warranty ceases to apply if it cannot be 
demonstrated that, after commencement of use, the central 
heating boiler has been serviced at least once a year by an 
installer authorised for that purpose by or on behalf of the gas 
company. The instructions for installation and use which we 
issue for the boilers concerned should be complied with in full. 

5.

 

The manufacturer’s liability under the agreement is expressly 
limited to fulfilment of the warranty obligations defined in this 
article. All claims for compensation, except for those relating 
to failure to fulfil the warranty obligations, are excluded. With 
due regard for the mandatory provisions regarding product or 
other liability, no rights may ever be derived at any time with 
regard to any consequential loss, loss of net worth or any loss 
whatsoever that might arise from defects in materials 
delivered or work performed by the manufacturer.                                                                                                                                                                    
In addition, all offers and agreements concerning deliveries 
and/or services to be made or provided by us are governed by 
the Conditions of Sale. A copy of these conditions will be sent 
to you free of charge on request. Conditions to the contrary 
are expressly rejected.  

 
 
 

 

6.

 

The warranty is effective only if the annex to this warranty 
certificate has been signed by the purchaser and returned to 
us within 8 days of the date of installation. By signing the 
warranty card the purchaser states his/her agreement that the 
items have been delivered in good condition. 

7.

 

If the installer’s business has been terminated before the end 
of the warranty period, the user may invoke our warranty 
obligations to the installer. 

 

 

 

Installers are required to carry out installation, commissioning and 
servicing work in accordance with the Benchmark Code of Practice 
which is available from the Heating and  Hotwater Industry Council 
who manage and promote the scheme. Visit 
www.centralheating.co.uk for more information.     

 
 

Use as intended

 

The appliance, as described in this documentation, is intended for 
heating rooms via a central heating installation and/or for supplying 
hot water. Any other use lies outside the intended use of the 
appliance. No liability can be accepted for loss or damage arising 
from incorrect use. 

16

 

CE DECLARATION 

Declaration of conformity in accordance with ISO IEC GUIDE 22. 

 

Manufacturer

 

Intergas Heating Ltd 

Address 

Building 94, Bay 1 Vantage Point 
The Pensnett Estate  
Kingswinford 
West Midlands 
DY6 7FS 

  
Hereby declares that the CH appliances: 
 
Compact HRE  30 OV 
Compact HRE  24 OV 
Compact HRE  18 OV 

 

 

 

meets the provisions of the following directives: 
 

 

Low Voltage Directive (2006/95/EC)  

 

Gas Appliances Directive (2009/142//EEC) 

 

Boiler Efficiency Directive for new oil- and gas-fired central 
heating boilers (92/42/EEC) 

 

EMC Directive (2004/108/EC) 

 

Ecodesign (2009/125/EG) 

 

Energy labelling 2010/30/EU 

 

 

H. Bosscher,  July 2015 

 

 

 

 

Summary of Contents for 18 OV

Page 1: ...5 30 OV G C 41 291 06 Installation service and user instructions Please read these installation instructions carefully before installing and using the appliance Keep these installation instructions wi...

Page 2: ...Installers are required to carry out installation commissioning and servicing work in accordance with the Benchmark Code of Practice which is available from the Heating and Hotwater Industry Council w...

Page 3: ...different gas type 39 11 Faults 40 11 1 Fault codes 40 11 2 Other faults 40 12 Maintenance 43 12 1 Disassembly 43 12 2 Cleaning 43 12 3 Assembly 44 12 4 Combustion 44 13 Electrical connections 45 13 1...

Page 4: ...gulations currently in force Read these instructions carefully before installing or using the appliance 1 3 Manual handling When moving the boiler always keep your back straight bend your knees don t...

Page 5: ...1 8 Service and technical support For information about specific adjustments installation maintenance and repair work please contact Intergas Heating Ltd Building 94 Bay 1 Vantage Point The Pensnett E...

Page 6: ...d input not exceeding 70kW Part 2 Air Supply BS 5546 2000 Installation of gas hot water supplies for domestic purposes BS 5549 1990 Forced circulation hot water systems BS 6700 1997 Design Installatio...

Page 7: ...Gas consumption G20 m3 h 0 58 1 94 0 75 2 46 0 79 2 80 Gas consumption G31 m3 h 0 22 0 74 0 28 0 94 0 30 1 07 Appliance pressure loss CH mWk See 10 5 See 10 5 See 10 5 NOx class natural gas 5 5 5 NOx...

Page 8: ...55 69 80 Sound power level LWA dB 45 45 50 CAUTION Please read all instructions before fitting this appliance This appliance is not intended for use of persons including children with diminished physi...

Page 9: ...J Mains lead 230 V AC without plug stripped B Flow CH K Condensate trap C Return CH M Ionisation Ignition electrode D Sight glass N Fan E Sensor S1 O Gas valve F Heat exchanger P Position of data plat...

Page 10: ...des direct burner ignition and flame supervision along with continuous modulation of the burner s gas supply 3 3 Parameter list All boiler adjustments are accessible through the parameter list in the...

Page 11: ...tection is active This means that the external pump operates and the exchanger is heated up if the temperature of the water present in it falls too far If the frost protection is actuated code 7 is di...

Page 12: ...tter two however the maximum is the temperature set on the display During CH operation the requested CH supply temperature is indicated on the operating panel The CH supply temperature can be set betw...

Page 13: ...on continuesly in the display the CH water pressure is shown By pressing the button continuesly in the display the ionisation current is shown 4 7 Frost protection FROST PROTECTION To prevent freezing...

Page 14: ...installing is connected to the appropriate connections on the boiler It is important to thoroughly flush the water circuits after isolating the boiler in order to remove any fluxes and debris from the...

Page 15: ...roof 087910 Weather slate flat roof 087372 Extension L 100 incl wall bracket 082975 Horizontal telescopic offset wall terminal Only to be used in combination with the base adapter on the boiler 08129...

Page 16: ...Intergas Heating Ltd 16 Plume management kit 081294 Elbow 90 for plume management kit 081284 Elbow 60 for plume management kit 081285 Extension L 100 incl wall bracket for plume management kit 081286...

Page 17: ...imensions A Supply CH 22 B Return CH 22 C Gas F Condensate drain 25 flexible G Drain PRV 15 H 710 Compact HRE OV 30 H 650 Compact HRE OV 24 H 590 Compact HRE OV 18 Z1 Standard flue pipe 60 100 concent...

Page 18: ...y be realized by opening a cupboard door Flammable fluids and materials must be stored at least 1m away from the boiler The wall on which the boiler is mounted must be sufficiently strong to support t...

Page 19: ...e 9 Connect the flexible tube from the condensate trap to the drain via an open connection The condensate discharge system must be made of plastic no other materials may be used The discharge duct mus...

Page 20: ...connection Always use the enclosed compression fittings 8 1 1 The CH system should be equipped with A drain tap at the lowest point s of the installation A heating system feed tank 8 1 2 Thermostatic...

Page 21: ...to provide access 4 Consult sections 8 3 1 and chapter 13 for making the connections 5 After making the desired connections plug the appliance into an earthed wall socket 8 3 1 Electrical connections...

Page 22: ...the boiler is adjusted to the most optimal value The Open Therm OT room thermostat has te be connected tot the contacts 11 and 12 of connector X4 see chapter 13 electrical diagram CAUTION Connecting...

Page 23: ...ee diagram B Gully C Condensate discharge from boiler D Servicable waste trap E 5 20 mm meter F 100 mm G 110 mm H 450 mm If an externally run condensate drainage pipe is used the following measures sh...

Page 24: ...r window into a dwelling 1200 mm K Vertically from a terminal on the same wall 1500 mm L Horizontally from a terminal on the same wall 300 mm M Above an opening air brick opening windows etc 300 mm N...

Page 25: ...etres CAUTION Only an Intergas approved flue is to be used with this product Failure to comply with this requirement will invalidate your guarantee and may lead to a dangerous situation The horizontal...

Page 26: ...y joint and at changes of direction Bends should be viewable from both directions where the inspection hatch cannot be positioned at the bend Where suitable access is not provided the appliance MUST N...

Page 27: ...st be obtained with all other gas appliances at the property working 9 1 3 Combustion The combustion for this appliance has been checked adjusted and preset at the factory for operation on the gas typ...

Page 28: ...set and the resistance in the CH installation For the water head of the pump and the pressure loss of the appliance see 10 5 3 Set the room thermostat higher than the room temperature The appliance wi...

Page 29: ...second period CH on 22 00 and 4 End second period CH off By pressing the button the new times will be stored in the boiler controller In the service display P appears When the clock is in period 1 or...

Page 30: ...is equipped with frost protection If the temperature of the heat exchanger becomes too low the burner switches on until the temperature of the heat exchanger is sufficient If there is a possibility o...

Page 31: ...o flash Pressing the key repeatedly results in a different function LED flashing each time When the LED is flashing the indicated function can be set with the and key The value set is shown on the dis...

Page 32: ...ion 1 1 1 0 step modulation off during CH operation 1 step modulation on during CH operation C Minimal CH rpm 30 30 30 Adjustment range 25 to 50 C External switch keep hot facility 40 40 40 Not applic...

Page 33: ...he pump setting can be adjusted Consult the manual of the external pump for advice Check the temperature difference between the appliance supply and return this must be approximately 20 C The minimum...

Page 34: ...ment must be performed first at maximum power and thereafter on the minumum power see 10 8 1 and 10 8 2 For reference reasons the tables below contain O2 and CO2 values When the CO2 or O2 value is inc...

Page 35: ...sure a capital H is shown in the display to ensure the appliance to run at maximum power 7 Wait until the reading of the flue gas analyser is stable minimal 3 minutes 8 Note the measured value O2 H o...

Page 36: ...ne 3P G31 CO2 CO2 Maximum value CO2 H CO2 H 0 3 Minimum value 8 4 9 4 Important The gas air ratio is set correctly when the measured value at minimum output is within the upper and lower limit Adjusti...

Page 37: ...5a is for natural gas 4b and 5b is for Propane The value measured at maximum output as noted during the measurement on maximum output CO2 H or O2 H Turning clockwise of the adjustment screw will rais...

Page 38: ...mBar Measured value am maximim power See 10 8 1 Prescribed value at minimum power CO2 H 0 3 CO2 H CO2 L 10 8 10 5 0 1 10 6 10 3 0 1 10 4 10 1 0 1 10 2 9 9 0 1 10 0 9 7 0 1 9 8 9 5 0 1 Example when us...

Page 39: ...ds the rear B 5 Replace the O ring C and the gas restriction D with the rings from the conversion set 6 Re assemble in reverse sequence 7 Open the gas tap 8 Check the gas connections before the gas va...

Page 40: ...ion gap Gas supply pressure too low of failling Gas valve or ignition unit not powered 5 Poor flame signal Condensate drain blocked Check adjustment of gas valve 6 Flame detection fault Replace igniti...

Page 41: ...on gap Replace the ignition electrode Replace the ignition unit on the gas valve 11 2 3 Burner resonating Possible causes Solution Gas supply pressure too low The house pressure switch may be faulty C...

Page 42: ...et for the installation Adjust the power See setting maximum CH power No No heat transfer as a result of lime scale or fouling in the heat exchanger De scale or flush the heat exchanger on the CH side...

Page 43: ...ipe is above the condensate drain pan connection Pull the bottom of the pipe forwards 2 and remove the pipe downwards 3 turning it anti clockwise 7 Lift the condensate drain pan on the left hand side...

Page 44: ...flue pipe components for leakage 12 Check the gas air adjustment 13 Fit the casing tighten the two screws left and right of the display and close the display cover 14 Check the heating and if applica...

Page 45: ...thermostat remove connection 6 7 8 9 Outdoor sensor 12k ohm 25 C 11 12 OpenTherm thermostat remove connection 6 7 Connector X2 230V 1 3 Room thermostat 230 AC 1 Switch live 3 Live fused 1 3 Frost the...

Page 46: ...Intergas Heating Ltd 46 13 3 Typical Y Plan connection 13 4 Typical S Plan connection...

Page 47: ...nition module 801477 Condensate trap 844187 Condensate collector 847037 Seal gas valve inlet 875757 O ring gas restriction ring 875827 O ring front plate Compact HRE OV 30 876597 O ring front plate Co...

Page 48: ...as company The instructions for installation and use which we issue for the boilers concerned should be complied with in full 5 The manufacturer s liability under the agreement is expressly limited to...

Page 49: ...Intergas Heating Ltd 49 17 GAS BOILER SYSTEM COMMISSIONING CHECKLIST...

Page 50: ...Intergas Heating Ltd 50 18 SERVICE RECORD...

Page 51: ..._______________________________________________________________________________________________________________ ________________________________________________________________________________________...

Page 52: ...a ISO 9001 certified production faccility Intergas Heating Ltd Intergas Heating Ltd Tel 01527 888000 88324802 Building 94 Bay 1 Vantage Point Fax 01384 279480 The Pensnett Estate info intergasheating...

Reviews: