1  IF-812 or IF-815 Terminal (Slave) 

Thank you for choosing an Interflex system. With an IF-812 or 
IF-815 terminal (slave), you have purchased a reliable device 
for capturing access data. 

Furthermore, with an IF-815 terminal, you can also capture time 
data and enter your PIN via a membrane keypad. 

 
Scope of delivery:   

 

IF-812 or IF-815 terminal (slave) 

 I/O 

controller 

board 

 Terminal 

board 

 Mortise 

lock 

 

Material for wall mounting 

 

Design frame optional 

 

  Please check the completeness and condition of the 

shipment upon receipt. 

 

 

2 Intended 

Use 

Slave terminals of the IF-812/IF-815 series are devices for capturing access data as well as for writing to 
RFID credentials. Furthermore, with an IF-815 terminal (slave), you can also capture time data. The device is 
designed for indoor and outdoor use (see note). Any other use is not in accordance with the intended 
purpose and is therefore not permitted. 

 

3  Assembly and Installation 

 

 

The following installation procedure has been proven and tested: 

1.  Install the cables. 

2.  Install the power supply. 

3.  Mount the IF-812/IF-815 housing. If the terminal is to be used for access control, an I/O controller board 

must also be mounted in a secured area. 

4.  Set the address. 

5.  Close the housing. 

6.  Put the IF-812/IF-815 into operation. 

 

95-10324_V2016-11-23 IF-812/IF-815

 

 

Summary of Contents for IF-812

Page 1: ...Use Slave terminals of the IF 812 IF 815 series are devices for capturing access data as well as for writing to RFID credentials Furthermore with an IF 815 terminal slave you can also capture time da...

Page 2: ...nal slave 100 m 4 x 2 x 0 6 mm 2 110 230 V mains cable to transformer or DC power supply unit 2a Low voltage cable to terminal board 3 4 x 2 x 0 6 mm We recommend installing a separate fuse protected...

Page 3: ...nto place 4 Secure the housing with the mortise lock 3 4 Mounting 1 Back panel of housing with terminal board 4 Rubber seal 2 Recommended cable feed Flush mounted 5 Plain washers 3 Installation cable...

Page 4: ...N OFF OFF Address 6 OFF ON OFF ON Address 7 OFF ON ON OFF Address 8 OFF ON ON ON 3 6 Wiring Power supply Power can be supplied via a 12 VAC 24 VAC power transformer via a 12 VAC 24 VAC low voltage pow...

Page 5: ...tact for anti tamper switch 5 Connection of door sensor handle or NC contact The I O controller board allows for access control The board can switch electric door openers up to max 30 V 2 A via an NO...

Page 6: ...tact can be changed from normally open NO to normally closed NC If two relay outputs are required a further I O controller board is needed Connection of sensors 5 Two sensors can be connected to the I...

Page 7: ...membrane keypad with 4 programmable buttons as well as a numeric keypad Device Protection Protection category III Degree of protection IP43 IP54 after sealing the mortise lock General Data Ambient te...