background image

 

3. To change the modelling lamp mode press [D], the Prop indicator will light up and 

the modelling lamp will be turned on, this indicates that your F121 is in sync 
mode and adjusting the power of flash tube will adjust the modelling lamp too.     
Press the modelling lamp mode button [D] again, the Prop indicator will turn off, 
the Free indicator will be lit and the LED display will be flashing, which indicates 
that you are independently adjusting the modelling lamp brightness. If the LED 
display stops flickering, this indicates that your F121 has resumed back to flash 
power adjustment mode. 
To switch the modelling lamp off press the modelling lamp mode button [D] 
again, so that the Free indicator and the modelling lamp are both off.   

4. To turn the Audio Indicator (beep) on, press the beep on/off button [F], the Audio 

Indicator light will be lit. To turn off press the button again and the Audio 
Indicator light will turn off   

5. Press the Power Up button [G] to increase the power. The maximum power is 

7.0. 

6. Press the Power Down button [K] to decrease the power. The minimum power is 

2.0. At the same time, the flash tube will flash once automatically to discharge 
the higher powered flash. 

7. To change the wireless mode, press the wireless channel/sensor selection 

button [N], the Cell indicator will light up, indicating the sensor flash triggering 
function is on; To switch the sensor flash triggering mode off and switch to 
wireless channel triggering press the button [N] again so that the first indicator 
light is lit (1), this indicates that the first channel is on. 
Press the button [N] again, the first indicator will turn off, while the second 
indicator will turn on (2), indicating the second channel is on. 
Press the button [N] again and the first and second indicator will be lit (1+2), 
which means the third channel is on. 
Press the button [N] again, both the first and second light will be off, which 
means the fourth channel is on. 

8. To utilize the wireless features the Interfit on-camera remote SKU: INT910 (Sold 

separately) is required. 

Important Directions For Use 

1. Please connect the power cord to a properly grounded electrical outlet, switch off 

the power supply when not in use. 

2. To avoid burns or injury, do not touch the reflector and the lamp when in use 

since the temperature is very high when on. 

3. If the LED displays the error codes E1, E2 or E3 stop using the device 

immediately and contact the retailer from who you purchased your unit. 

4. To prevent damage to the internal components, the power of the modelling lamp 

should not be used above 75w. 

5. Do not use in a wet environment. 

Wireless channel remote settings 

(Interfit on-camera Remote INT910 sold separately) 

 
 
 
 
 
 
 
 
 
 
 
 

Technical data 

Specification 100WS 

200WS 

Guide No. 

GN28 

GN42 

100% recycling time 

1-2S 

Flash adjustable rate 

2.0-7.0 

Modelling lamp power     

75W 

Colour temperature 

5600

˚

K ± 200

˚

Triggering mode 

Wireless

Light sensor sync

Sync cord 

Trigger voltage 

5.6V 

Sensor sync distance 

10M 

Working voltage 

220V/50Hz or 120V/60Hz 

Battery required: 
A23/MN21/LRV08 