Step 1: Connect to Network and Power
Terminal Block Wiring
Return to Setup Mode
Status LED
Step 3: Create Pages in CueServer Studio
Step 2: Configuration
If using Power-over-Ethernet, simply attach the powered network cable.
If using an external DC power supply, attach a 12VDC 12W source to the
terminal block. Also attach the network cable.
The Status LED light will illuminate Green when the touchscreen receives power.
The pluggable terminal block can optionally be
used to provide DC power or to connect external
accessories to the touchscreen.
There are two different ways to return to setup mode:
• Press and hold the
Reset
button for 3 seconds.
• Or, touch and hold the lower-left corner of the
screen when powering on, or within 5 minutes after
power-on.
D0652A 1/22/19
Power On
Setup Mode
Running Normally
Booting
Searching for Host
Error
When configuration is complete, press
Exit Setup
.
The touchscreen will connect to the chosen CueServer and
display the page layouts for the station.
Use
CueServer Studio
to create pages for the touchscreen.
(http://interactive-online.com/cueserver2/downloads)
When the touchscreen is powered for the first time, the
Panel Setup
screen
will appear automatically.
Network Configuration
By default, the touchscreen will obtain a unique IP address on the network
using DHCP.
If DHCP is unavailable or undesired, use the
Network
tab to specify a
static IP address.
Station Configuration
The touchscreen requires a connection to a CueServer on the network.
Use the
Station
tab to choose a CueServer and to set the touchscreen’s
Station Number.
General Settings
In the General tab, the touchscreen’s screen brightness and energy saving
settings can be adjusted.
12VDC Input 12VDC Output Contact 1 Output 1
Gr
ound
Gr
ound
Contact 2 Output 2
Optional
12VDC Input
Contact 1
Contact 2
Output 1
Output 2
12VDC Ou
t
Gr
ound
Switch 2
Switch 1
LED 1
LED 2