background image

Step 1: Connect to Network and Power

Terminal Block Wiring

Return to Setup Mode

Status LED

Step 3: Create Pages in CueServer Studio

Step 2: Configuration

If using Power-over-Ethernet, simply attach the powered network cable.

If using an external DC power supply, attach a 12VDC 12W source to the 

terminal block.  Also attach the network cable.

The Status LED light will illuminate Green when the touchscreen receives power.

The pluggable terminal block can optionally be 

used to provide DC power or to connect external 

accessories to the touchscreen.

There are two different ways to return to setup mode:

•  Press and hold the 

Reset

 button for 3 seconds.

•  Or, touch and hold the lower-left corner of the 

screen when powering on, or within 5 minutes after 

power-on.

D0652A 1/22/19

Power On

Setup Mode

Running Normally

Booting

Searching for Host

Error

When configuration is complete, press 

Exit Setup

.

The touchscreen will connect to the chosen CueServer and 

display the page layouts for the station.

Use 

CueServer Studio

 to create pages for the touchscreen. 

(http://interactive-online.com/cueserver2/downloads)

When the touchscreen is powered for the first time, the 

Panel Setup

 screen 

will appear automatically.

Network Configuration

 

By default, the touchscreen will obtain a unique IP address on the network 

using DHCP.

If DHCP is unavailable or undesired, use the 

Network

 tab to specify a 

static IP address.

Station Configuration

 

The touchscreen requires a connection to a CueServer on the network.

Use the 

Station

 tab to choose a CueServer and to set the touchscreen’s 

Station Number.

General Settings

 

In the General tab, the touchscreen’s screen brightness and energy saving 

settings can be adjusted.

12VDC Input 12VDC Output Contact 1 Output 1

Gr

ound

Gr

ound

Contact 2 Output 2

Optional

12VDC Input

Contact 1

Contact 2

Output 1

Output 2

12VDC Ou

t

Gr

ound

Switch 2
Switch 1

LED 1

LED 2

Reviews: