background image

1

Electrical Adjustment Procedure

1

Specifications

2

Electrical Parts List

3, 4

Top and Bottom View of P.C. Board

5, 6

Wiring Diagram

7

Block Diagram 

8

Schematic Diagram

9, 10, 11, 12

Exploded View of Cabinet & Chassis / Mechanical Parts List

13, 14

Ass’y Drawing

15, 16

CONTENTS

IDLE CURRENT

A. Setting

Set the master volume minimum.

B. Connection

C. Adjustment

– Adjust VR301 so that the current through the R237, R236,  R342, R343 become 10 milliampere.
– When that voltage across the “TP1” to “TP2” becomes 10 millivolt, the current becomes 10

milliampere.

ELECTRICAL ADJUSTMENT PROCEDURE

TP1

TP2

R237

R342

R236

R343

VR201

VR301

AMP B’D

VOLT METER

Reviews: