PROGRAM TIMER
13
PW-642
1) You can adjust AC output time if pressing the AC OUTLET button lengthily in the STANDBY mode.
2) Enter AC power output time using the NUMERIC button.
3) Press the ENTER button for saving or ending.
4) Setting is done within the range of 1 through 20sec, and basic setting is set to 10sec.
11. Time Calibration Adjustments
1) Press the TIME button lengthily in the STANDBY mode to start setting.
2) Enter setting value with the NUMERIC button.
Setting is done within the range of 1 through -30 ~ +30, and basic setting is set to +6.
Time is compensated by 0.2 per day every stage.
3) +/- before number can be changed if pressing the TIME button. (+) compensates rapidly, and (-) compensates slowly.
4) Press the ENTER button for saving or ending.
12. Key Lock
1) This is function to protect the user’s setting contents. “KEY LOCK” is displayed for a short time on the display
window if pressing the ENTER button lengthily, and entry of all function buttons is shut-off.
2) “KEY UNLOCK” is displayed for a short time on the display window if pressing the ENTER button lengthily
again, and entry of all function buttons is available.
13. Operating the unit using free application software
APPLICATION PROGRAM is program to more effectively manage the current reservation status, etc or setting for
installation and maintenance of PW-642(PROGRAM TIMER) equipment. Data base setting by weekday is
available. Much time for setting equipment can be saved with the DB automatic generation function. In addition,
inter-equipment interface is provided using both a GUI pattern of clean display and the RS-232 port.
(Please download APPLICATION PROGRAM and manual from the Inter-M homepage for use.)
14. The Others
1) You can turn ON/OFF AC power output with the AC OUTLET button.
If desiring AC power output, press the AC OUTLET button to turn on LED.
2) No output is done even though MELODY is generated with LED of the OUTPUT button turned off.
If desiring to output MELODY channel, turn on LED by pressing the OUTPUT button.
VOICE RESERVATION BROADCASTING is always output with regardless of status of the output button.
AC OUTLET
OUTPUT
1
2
3
4
5
6
0
7
8
9
CANCEL
DELETE
TIME
AM/PM
HOUR/MIN.
DAY
CH
COPY
TRACK
AC OUTLET
OUTPUT
AC OUTLET
OUTPUT
Summary of Contents for PW-642
Page 1: ...Operation Manual Program Timer PW 642...
Page 21: ...NOTE...