POWER DISTRIBUTOR
8
PD-6359
3. ADDRESS SWITCH
It is the switch setting up the device number.
For the details of Equipment Setting, please refer to page 4.
4. LINK IN/OUT TERMINAL
It is the communication terminal for monitoring the status of service voltage. Link In terminal is connected to
the previous device, and Link Out terminal will be connected to the next device.
※
IN/OUT Terminals are all same.
5. TERMINATION SWITCH (LOAD/OPEN)
It is the switch which is set for stable data receiving/transmitting of link in/out.
For the details of Equipment Setting, please refer to page 4.
※
Caution: communication error may occur if it is not set correctly.
6. AC FUSE
It is the fuse for AC power, and if error occurs in the device, it shuts off the AC power to protect the device. If
you want to replace the fuse, please use the one which rated capacity is same.
7. DC FUSE
It is the fuse for DC power, and if error occurs in the device, it shuts off the DC power to protect the device. If
you want to replace the fuse, please use the one which rated capacity is same.
8. DC POWER OUTPUT TERMINAL (UNSWITCHED)
It is the terminal which supplies the power to the device operated by DC 24V.
9. AC POWER CORD
10. REMOTE TERMINAL
This is the input terminal for remote-controller
When the contact signal sent to this terminal (HOT, COM) ,it operates automatically.
But only works when the power switch is off.
PIN NO. Functions
1 RS-485 Data - A
2 RS-485 Data - B
3 RS-485 Data - Z
4 NA
5 GND
6 RS-485 Data - Y
7 NA
8 NA