1.  AMP INPUT TERMINALS

These terminals are connected to the output of a low-impedance amplifier like the Inter-M OT-4240
(4

/60W), OT-4480 (4

/120W) or OT-4960 (4

/240W).

2.  SPEAKER OUTPUT TERMINALS

These output terminals may be connected with high-impedance distributed speaker systems. 

For 120VAC operation, the 70V output terminal is recommended. For 230VAC operation, the 100V or 70V
terminals may be used. 

The chart below shows recommended impedances.

100V

70V

25V

OT-4240 / 120VAC

81.7

10.4

OT-4240 / 230VAC

166.7

81.7

OT-4480 / 120VAC

40.8

5.2

OT-4480 / 230VAC

83.3

40.8

OT-4960 / 120VAC

20.4

OT-4960 / 230VAC

41.6

20.4

Summary of Contents for OT-4240

Page 1: ...OT 4240 4480 4960 Output Transformer Unit OT 4960 OUTPUT TRANSFORMER UNIT...

Page 2: ...ng 2 Installation Environment 2 Important Safety Instructions 2 Features 3 Accessories 3 Operation 3 Rear Panel 4 Applications 5 Block Diagram 6 Specifications 8 Service Procedures 9 Schematic 9 Parts...

Page 3: ...ts filled with liquids such vases shall be placed on the apparatus Worded WARNING FOR YOUR PROTECTION PLEASE READ THE FOLLOWING WATER AND MOISTURE Unit should not be used near water e g near a bathtub...

Page 4: ...her apparatus including amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A groundin...

Page 5: ...level for use with high impedance speaker systems FLEXIBLE OPERATION Four independent channels allow for four mono or two stereo zones EXPANDABLE AND ADAPTABLE Line Out expansion port for additional O...

Page 6: ...KER OUTPUT TERMINALS These output terminals may be connected with high impedance distributed speaker systems For 120VAC operation the 70V output terminal is recommended For 230VAC operation the 100V o...

Page 7: ...5 OT 4240 4480 4960 OUTPUT TRANSFORMER UNIT Applications Applications QD 4960 OT 4960...

Page 8: ...Block Diagram Block Diagram OT 4240 4480 6 OT 4240 4480 4960 OUTPUT TRANSFORMER UNIT...

Page 9: ...7 OT 4240 4480 4960 OUTPUT TRANSFORMER UNIT Block Diagram Block Diagram OT 4960 240W 100V 41 6 ohm 70V 20 4 ohm COM 4ohm...

Page 10: ...83 3 OT 4960 70V 20 4 100V 41 6 Input OT 4240 4 60W OT 4480 4 120W OT 4960 4 240W Frequency Response 20Hz 20kHz GENERAL Weight OT 4240 11 5kg 25 3lb OT 4480 14 5kg 32lb OT 4960 21 5kg 47 4lb Dimension...

Page 11: ...y contacting your warranty provider Variations and Options Variations and Options Variations Products supplied through legitimate sources are compatible with local AC power requirements Options No opt...

Page 12: ...any but rather a global company that is truly international in scope with factories and offices in Korea and China and sales and marketing operations located in Japan Europe and the U S A With more th...

Reviews: