background image

OUTPUT TRANSFORMER UNIT

2

OPT-100D

Installation

Unpacking

Unpacking

Although your OPT-100D is neither complicated nor difficult to operate, we recommend you take a few minutes
to  read  this  brief  manual  and  familiarize  yourself  with  the  important  information  regarding  product  features,
setup and operation.

As with most electronic devices, we strongly recommend you to retain the original packaging. In the unlikely
event the product must be returned for servicing, the original packaging (or reasonable equivalent) is required.

Installation

Environment

Never  place  this  product  in  an  environment  which  could  alter  its  performance  or  reduce  its  service  life.  Such
environments usually include high levels of heat, dust, moisture, and vibration.

IMPORTANT SAFETY INSTRUCTIONS

1.  Read these instructions.
2.  Keep these instructions.
3.  Heed all warnings.
4.  Follow all instructions.
5.  Do not use this apparatus near water.
6.  Clean only with dry cloth.
7.  Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8.  Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including

amplifiers) that produce heat.

9.  Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades

with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide
blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult
an electrician for replacement of the obsolete outlet.

10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and

the point where they exit from the apparatus.

11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus.

When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.

13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14.  Refer  all  servicing  to  qualified  service  personnel.  Servicing  is  required  when  the  apparatus  has  been

damaged  in  any  way,  such  as  power-supply  cord  or  plug  is  damaged,  liquid  has
been  spilled  or  objects  have  fallen  into  the  apparatus,  the  apparatus  has  been
exposed to rain or moisture, does not operate normally, or has been dropped.

S3125A

Summary of Contents for OPT-100D

Page 1: ...Operation Manual Output Transformer Unit OPT 100D...

Page 2: ...ction It has heed to be easy to disconnect the device To disconnect the device from power separate AC input cable from inlet or unplug the AC Cord CAutION These servicing instructions are for use by q...

Page 3: ...RMER UNIT 1 OPT 100D Contents Contents Unpacking 2 Installation Environment 2 Important Safety Instructions 2 Features 3 Rear Panel 4 Applications 5 Specifications 7 How to install the rack 9 Service...

Page 4: ...s or other apparatus including amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A g...

Page 5: ...s implemented 100W 2 Channel at Slim Compact Size 1RU HALF RACK SIZE DEPTH 280mm and it can be easily installed at tiny space along with light weight High quality output transformer Providing clear an...

Page 6: ...0 If you want to use 70V output level it connects 70V with COM Speaker s minimum impedance is 49 NOTE Before connecting speakers to the unit be sure to disconnect the AC power cable Make certain that...

Page 7: ...0V 100 INPUT 1 AC INPUT SPEAKER OUT REMOTE POWER VCA CONTROL 2CH BRIDGE V1 C1 G C2 V2 MODE ON OFF HPF 4dBu 20dBu GAIN OFF REMOTE ON POWER CLASS 2 WIRING G INPUT 2 G CH 2 4 4 8 CH 1 BRIDGE NOTE When co...

Page 8: ...OPT 100D OPT INPUT CH 2 CH 1 SPEAKER OUTPUT CLASS 2 WIRING CH 2 CH 1 100V 70V COM 100V 70V COM 70V 49 100V 100 OPT INPUT CH 2 CH 1 SPEAKER OUTPUT CLASS 2 WIRING CH 2 CH 1 100V 70V COM 100V 70V COM 70V...

Page 9: ...ted Output 1kHz 100W x 2 Input 20V 100V Output Voltage Minimum Impedance 100V 10V 100 70V Output Voltage Minimum Impedance 70V 7V 49 Frequency Response 1W OPT 100D 80Hz 20kHz 3dB OPT 100D AMP 80Hz 17k...

Page 10: ...OUTPUT TRANSFORMER UNIT 8 OPT 100D DIMENSIONS 177 210 5 44 280...

Page 11: ...OUTPUT TRANSFORMER UNIT 9 OPT 100D How to install the rack How to install the rack Y NN Y NN Y NN Y NN 4 7 5 4 5BLF GFFUT PGG OFBS SPOU 1BOFM OTUBMM 3BDL NPVOU 5 VTJOH TDSFXT AMP BLANK MOUNT...

Page 12: ...TRANSFORMER UNIT 10 OPT 100D Y NN Y NN Y NN 5BLF GPPUT PGG OTUBMM 5 VTJOH 4DSFX 4 7 015 PS 4 7 Y NN Y NN 3 3 0 5 5 4 5 5 5 4 5BLF GFFUT PGG OFBS SPOU 1BOFM OTUBMM 3BDL NPVOU 5 VTJOH TDSFXT AMP OPT RAC...

Page 13: ...Schematic A Schematic is available by contacting your warranty provider Parts List A Parts List is available by contacting your warranty provider Warranty Warranty Warranty terms and conditions vary b...

Page 14: ...NOTE...

Page 15: ...any but rather a global company that is truly international in scope with factories and offices in Korea and China and sales and marketing operations located in Japan Europe and the U S A With more th...

Reviews: