Inter-m MA-106N Operation Manual Download Page 7

PUBLIC ADDRESS AMPLIFIER

5

MA-106N

Rear Panel

Rear Panel 

1. AC POWER CORD

Connect this cable to an AC outlet.

2. SPEAKER OUTPUT TERMINAL

These terminals are used to connect speakers to the unit. You may select 4

 conventional operation, or high

impedance operation at either 70V/82

 or 100V/167

.

(USA/CANADA & Associated : 25V/10.5

 or 70V/82

)

Can’t use these terminals at the same time.
NOTE:  The  unit  is  disable  to  operate  in  case  of  the  total  impedance  is  less  than  the  rated  impedance

indicated. (If you’re running speakers, you have to make sure total impedance does not go below
the rated impedance.)

3. EXTERNAL MUTE CONTROL TERMINAL

Be able to use this terminal when you want to cut off the unit’s output signal from the external equipment.

4. TEL IN TERMINAL

This is the audio signal input terminal of switchboard.
If the signal is inputted to the terminal, you are able to control the output of other input signals by the priority
control volume of TEL IN.

5. TEL IN PRIORITY CONTROL VOLUME

This is able to control the mute level of INPUT 1~3 when the signal is inputted from the TEL IN terminal.

6. INPUT 3 TERMINAL

This is an unbalanced input terminal and connected with the external units.(CD, DVD, computer, etc.)
If you connect with computer, ‘Y’ jacks are required.
- Euro Block : Unbalanced
- RCA : Unbalanced

SIG GND

+ -

G

+ -

G

1

2

3 4

5

6

7

8

9

10

11

Summary of Contents for MA-106N

Page 1: ...Operation Manual Public Address Amplifier MA 106N...

Page 2: ...te AC input cable from inlet or unplug the AC Cord CAutION These servicing instructions are for use by qualified service personnel only To reduce the risk of electric shock do not perform any servicin...

Page 3: ...nstallation Environment 2 Important Safety Instructions 2 Features 3 Operation 3 Front Panel 4 Rear Panel 5 Connecting Speakers 7 Applications 8 Block Diagram 9 Specifications 10 Service Procedures 12...

Page 4: ...other apparatus including amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A ground...

Page 5: ...nd Easy to control the tone due to user frequency which is including bass and treble ADDITIONAL FUNCTIONS Easy to use with the various additional functions including power of phantom MIC TEL IN PRIORI...

Page 6: ...INPUT VOLUME These knobs control the volume level of INPUT 1 3 4 TONE CONTROL These knobs provide continuous control of the high 10kHz and low 100Hz frequency response by adding up to 12dB of cut dec...

Page 7: ...o below the rated impedance 3 EXTERNAL MUTE CONTROL TERMINAL Be able to use this terminal when you want to cut off the unit s output signal from the external equipment 4 TEL IN TERMINAL This is the au...

Page 8: ...with 6 3 Phone Jack the rear panel s MIC input terminal don t output the signal 10 SELECT SWITCH OF INPUT 1 PHANTOM MIC This switch selects a kind of INPUT 1 s MIC on the rear panel Be able to use ei...

Page 9: ...certain that the total impedance is not less than the rated impedance indicated 2 Don t have to use several speaker terminals at the same time 3 If you re just dealing with the high impedance termina...

Page 10: ...MA 106N Applications Applications SIG GND G G You have to select one between 4 and High voltage output You never use both 4 with High voltage output at the same time If you do this system will have d...

Page 11: ...PUBLIC ADDRESS AMPLIFIER 9 MA 106N Block Diagram Block Diagram...

Page 12: ...B Tone Control BASS 100Hz 12dB TREBLE 10kHz 12dB Operating Temperature 10 C 40 C Power Source 100 120VAC or 220 240VAC 50 60Hz Supplied AC mains depends on country requirements Power Consumption 24W W...

Page 13: ...PUBLIC ADDRESS AMPLIFIER 13 MA 106N 11 MA 106N DIMENSIONS...