6a)  MANUAL MUTE CONTACT CLOSURE

Contact Closure between pins 1 and G will mute input channel 2, or mute channels 2 and 3 together if they
are linked using mix configuration switch #6. This is typically used when a microphone plugged into channel
1 has a push-to-talk switch, whereby the pressing of the switch not only turns on the mic but also mutes the
signal  on  channel  2,  or  channels  2  and  3  if  they  are  linked.  When  the  switch  is  released,  the  signal  on
channels 2 and 3 returns.

6b)  MASTER SYSTEM STANDBY

The  MA-106A  has  a  power  saving  standby  mode  which  can  be  triggered  by  25  minutes  of  audio
inactivity (below a certain audio input level), or by contact closure of the Master System Standby connector
pins  G  &  2.  When  in  standby  mode,  the  front  panel  power  LED  will  turn  red,  changing  back  to  blue  for
normal  operating  mode.  Standby  mode  is  ended  when  there  is  audio  signal  present  again,  or  when  the
Master System Standby circuit is opened. Master system standby has priority over standby due to inactivity.

7. ZONE 2 LEVEL CONTROL

This controls the level of the Zone 2 output signal.

8. MIX CONFIGURATION DIP SWITCHES

- Switches 1, 2, and 3: Zone 2 Assign 

These assign each input to Zone 2 output, post-level control.  There is no effect to the main output mix.

- Switches 4-5: VOX Trigger -

The MA-106A has the ability to trigger a mute on channel 2 or 3 from the presence of an audio signal on
channel 1 or 2. This is called Voice Operated Switching, or VOX. Input 2 has priority over input 3, and
input 1 has priority over input 2. Input 1 also has the ability to use a contact closure trigger such as a mic
push-to-talk switch for priority muting of channel 2. Additionally, input 1 can be set to have priority over
both inputs 2 and 3 together (see switch 6).  
The MA-106A has audio detecting LEDs on each input. When the VOX TRIG switches are set to ON for
inputs 1 or 2, the same signal level which activates the LED is used as the VOX trigger. VOX mutes the
dependent channel until the trigger signal falls back below the LED threshold. Each input features a rear
panel gain trim that first optimizes the overall input sensitivity for each input, but can also serve to fine-tune
the sensitivity of the signal detector which creates the VOX trigger point for each input.  

- Switch 6: Mute Link 2&3

When this switch is turned on, it sets the channel 1 VOX trigger or Manual Mute contact closure to mute
both channels 2 and 3.  If only channel 2 is to be affected, leave it off.

- Switch 7: Low-Cut Filter

This switch turns on a 400Hz 6dB/oct low-cut filter affecting the main and PRE outputs but not the zone 2
outputs.  This is useful for providing the proper EQ for paging horns.

- Switch 8:  CH 1 MIC Phantom Power

This pr18V phantom power to input 1 for use with condenser and electret microphones.

9. INPUT 3 GAIN CONTROL

Input 3 gain trim range is adjustable from -10dB to +10dB.

10. INPUT 2 GAIN CONTROL

Input 2 gain trim range is adjustable from -10dB to +10dB. This control is also used to fine tune the signal
threshold that will trigger the muting of input 3.

MA-106A_E_130177 8  12. 3. 12.  오전 11:21  페이지 9

Summary of Contents for MA-106A

Page 1: ...global company that is truly international in scope with factories and offices in Korea and China and sales and marketing operations located in Japan Europe and the U S A With more than 850 employees...

Page 2: ...Operation Manual Public Address Amplifier MA 106A MA 106A_E_130177 8 12 3 12 11 21 2...

Page 3: ...onnect the device from power separate AC input cable from inlet or unplug the AC Cord The socket outlet shall be installed near the equipment and shall be easily accessible CAutION These servicing ins...

Page 4: ...t 2 Important Safety Instructions 2 Features 3 Operation 3 Front Panel 4 Rear Panel 5 Connecting Speakers 8 Typical Applications 9 Block Diagram 10 Specifications 11 Service Procedures 13 Schematic 13...

Page 5: ...cluding amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has...

Page 6: ...cally converted to Master System standby Mode Operation Operation 1 Before you plug the power cord to AC outlet please set the power switch OFF Tone Control center and volume level minimum 2 Please ma...

Page 7: ...resent 3 INPUT LEVEL CONTROLS These control the level of the three input channels 4 BASS AND TREBLE CONTROLS These control the bass and treble of the main amplifier output 5 MASTER VOLUME CONTROL This...

Page 8: ...ONE 2 output provides two signals 1 a low impedance output that is capable of continuously driving 1 Watt into an 8 Ohm loudspeaker and 2 a 600 Ohms transformer balanced output Zone 2 output is contro...

Page 9: ...perated Switching or VOX Input 2 has priority over input 3 and input 1 has priority over input 2 Input 1 also has the ability to use a contact closure trigger such as a mic push to talk switch for pri...

Page 10: ...ol is also used to fine tune the signal threshold that will trigger the muting of input 2 or inputs 2 and 3 if linked 12 INPUT 1 CONNECTOR A 3 5mm Euroblock connector is used for input 1 and can be us...

Page 11: ...total impedance is not less than the rated impedance indicated 2 Don t have to use several speaker terminals at the same time 3 If you re just dealing with the high impedance terminal then make sure t...

Page 12: ...o mono at the input In this example all three inputs are assigned to Zone 2 via the DIP switches Because the mic is set up for push to talk the IN 1 VOX trigger switch is left off IN 2 VOX trigger is...

Page 13: ...PUBLIC ADDRESS AMPLIFIER 10 MA 106A Block Diagram Block Diagram MA 106A_E_130177 8 12 3 12 11 21 13...

Page 14: ...X Trigger Input 1 SW5 VOX Trigger Input 2 SW6 Mute Link Input 2 3 SW7 Low Cut 400Hz 6dB Oct SW8 INPUT1 Phantom Power 18V Manual Mute Contact Closure Pin 1 G Input 1 Mute Trigger Master System Standby...

Page 15: ...PUBLIC ADDRESS AMPLIFIER 12 MA 106A DIMENSIONS MA 106A_E_130177 8 12 3 12 11 21 15...

Page 16: ...arranty terms and conditions vary by country and may not be the same for all products Terms and conditions of warranty for a given product may be determined first by locating the appropriate country w...

Reviews: