background image

LINE MONITOR

2

LM-618

Unpacking

Unpacking

Although your LM-618 is neither complicated nor difficult to operate, we recommend you take a few minutes to
read this brief manual and familiarize yourself with the important information regarding product features, setup
and operation.

As with most electronic devices, we strongly recommend you retain the original packaging. In the unlikely event
the product must be returned for servicing, the original packaging (or reasonable equivalent) is required.

Installation

Installation

Environment

Never place this product in an environment which could alter its performance or reduce its service life. Such
environments usually include high levels of heat, dust, moisture, and vibration.

IMPORTANT SAFETY INSTRUCTIONS

1.  Read these instructions.
2.  Keep these instructions.
3.  Heed all warnings.
4.  Follow all instructions.
5.  Do not use this apparatus near water.
6.  Clean only with dry cloth.
7.  Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8.  Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including

amplifiers) that produce heat.

9.  Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades

with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide
blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult
an electrician for replacement of the obsolete outlet.

10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and

the point where they exit from the apparatus.

11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus.

When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.

13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14. Refer all servicing to qualified service personnel. Servicing is required when the

apparatus has been damaged in any way, such as power-supply cord or plug is
damaged, liquid has been spilled or objects have fallen into the apparatus, the
apparatus has been exposed to rain or moisture, does not operate normally, or has
been dropped.

S3125A

S3125A

Summary of Contents for LM-618

Page 1: ...Operation Manual Line Monitor LM 618 Rack mount products in the Western Hemisphere North America South America and the Caribbean do not have handles installed due to customer preference ...

Page 2: ...s are for use by qualified service personnel only To reduce the risk of electric shock do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protecti...

Page 3: ...ontents Unpacking 2 Installation Environment 2 Important Safety Instructions 2 Features 3 Operation 4 Front Panel 4 Rear Panel 5 Applications 6 Block Diagram 7 Specifications 8 Service Procedures 9 Schematic 9 Parts List 9 Warranty 9 ...

Page 4: ...apparatus including amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacem...

Page 5: ...EVEL ADJUSTMENT The volume of monitor speaker is adjustable by its designated volume knob BUILT IN MONITOR SPEAKER The status of each input signals can be checked by highly qualified monitor speaker that offers loud and clear sound Operation Operation 1 Unit starts to work when the power switch on the rack is turned on 2 Please choose the channel needed to be checked and adjust the sound level and...

Page 6: ... by the channel selection switch 3 CHANNEL SELECTOR SWITCHES 1 8 Eight switches select any channel s output to be monitored by the front panel speaker 4 CHANNEL VOLUME The selected channel signal is amplified by the internal amplifier and it operates the monitor speaker The level of the signal can be increased when the rotator for the channel volume is turned clockwise and decreases when turned co...

Page 7: ...attery source to these terminals Make certain the red terminal is connected to the battery s positive side and the black terminal to the battery s negative side 3 LINE OUTPUT This Jack is for supplying the signal from the power amp with a line output by by passing the line input signal The signal to channel 1 goes directly to the line output without any attenuation ...

Page 8: ...LINE MONITOR 6 LM 618 Applications Applications AMP 1 AMP 2 AMP 3 AMP 4 LM 618 MIXER ...

Page 9: ...LINE MONITOR 7 LM 618 Block Diagram Block Diagram ...

Page 10: ...tivity 1V Monitor Speaker Output Power 3 4V 8Ω Operation Temperature 10 C 40 C Power Source 24V DC Power Consumption 350mA Weight SET 4 6kg 10 1lb Dimensions SET 482 W x88 H x380 D mm 19 W x3 5 H x15 D in Specifications and design are subject to change without notice Specifications Specifications ...

Page 11: ...tic A Schematic is available by contacting your warranty provider Parts List A Parts List is available by contacting your warranty provider Warranty Warranty Warranty terms and conditions vary by country and may not be the same for all products Terms and conditions of warranty for a given product may be determined first by locating the appropriate country which the product was purchased in then by...

Page 12: ...n company but rather a global company that is truly international in scope with factories and offices in Korea and China and sales and marketing operations located in Japan Europe and the U S A With more than 850 employees around the globe Inter M is well poised for further growth and expansion Inter M Americas Inc 13875 Artesia Blvd Cerritos CA 90703 USA TEL 1 562 921 0313 FAX 1 562 921 0370 Home...