Factory Settings
All of the LevelMaster variables can be restored to their default
values with this window displayed. The defaults are restored by
pushing the Auto/Manual button (right under ‘Restore’ on the
screen). The values saved will be:
Slope
0.0%
Display contrast
63%
Display type
A
Rotation Comp.
Off
Minimum pulse width
80 ms (for proportional time)
Minimum Duty Cycle
25% (for proportional current)
Valve cycle time
250 ms
Valve dead band
0.5% grade
Valve gain
50%
Derivative gain
Low
Filtering
- - I - - - (position 4)
Hydraulic AI
Off
AI Sensitivity
15%
AI Time-Out
2 seconds
Sensor axis
Fwd/Back
Sensor direction
1 -> Forward
Valve type
Proportional time
Horn
Off
There may be several LM2-C sensors connected to the data bus. If
so, it is necessary to select the sensor to use with this control box.
The serial number printed on the sensor box is shown. If there is
more than one sensor available, use the up and down arrow keys to
display the serial numbers of the available sensors. Press “OK” to
use the sensor currently displayed. If a sensor had been selected at
some point in the past, its serial number will have a star beside it.
Pick your language...
The final screen in the menu displays the phone number. Outside
of North America, dial +01.519.235.4585.
LevelMaster 2C Instructions v0.5 (Grader) (8/7/03)
page 10 of 14
Factory settings
Restore Next
LATEC Instr. Inc
5192354585 Next
Francais
Changer Suite
English
Change Next
Sensor #12345*
OK Next
Sensor #23456
OK Next