1.Mode botton:When press this botton,the operation mode   

   change as the following sequence:  

Remark : For the cooling  only model, the  heating  mode is 

                    skipped.  

2.Timer  on  button : Press this button, timer on function is   

   active. Then  every  press, the time  increase 0.5h, after   

   10h, 1h  increasement  after  each press. If  cancel  this 

NAME AND OPERATION OF THE BUTTON ON THE WIRE CONTROLLER  

  AUTO  

ĺ

 

COOL   

ĺ

 

 DRY 

ĺ

 

HEAT  

ĺ

 

 FAN  

TIMER 

TEMP  

RESET  

LOCK 

MODE 

FAN   

0

TURBO 

DIRECT  

ON/OFF BUTTON  

AJUDSTMENT BUTTON  

DIRECT/ 

HORIZONTAL SWING BUTTON  

VERTICAL SWING BUTTON  

LOCK BUTTON  

FAN SPEED SELECTION  

AJUDSTMENT BUTTON  

ON 

OFF 

TIMER 

ECO 

FOLLOW 

ME 

SPEED 

MODE BUTTON  

TIMER ON BUTTON  

TIMER OFF BUTTON  

ECONOMY OPERATION  BUTTON  

FOLLOW ME BUTTON  

RESET BUTTON  

TURBO BUTTON  

Summary of Contents for KJR-12B/DPBG(T)-E

Page 1: ...IRED CONTROLLER OF AIR CONDITIONER MAN O KJR12B 0615 intensity mx OWNER S MANUAL KJR 12B DPBG T E KJR 12B DPBG T E H Please read this manual carefully before operation and keep it for future reference...

Page 2: ...N THE WIRE CONTROLLER 3 5 INSTALLATION METHOD 4 6 NAME AND OPERATION OF THE BUTTON ON THE WIRE CONTROLLER 5 7 USING METHOD 7 AUTOMATIC OPERATION 7 COOLING HEATING FAN ONLY OPERATION 8 DRY OPERATION 8...

Page 3: ...rve the following safety precautions for they are very important Before you come to the text please be familiar with the following markers and icons and comply with the precautions WARNING CAUTION Fol...

Page 4: ...ion mode 3 LCD display 4 Timer for rest time 2 SUMMARIZE FUNCTION SUMMARY If you want to move or re install your Wire Controller please contact with local dealer Do not disassemble your Central Contro...

Page 5: ...kipped 2 Timer When adjust setting on time or only on time is set the ON is lighted When adjust setting off time or only off time is set the OFF is lighted If on and off timer are both set the ON and...

Page 6: ...dis appear 7 Temperature display zone Generally it displays setting temperature it can be adjusted by press temperature button and But in fan mode no display here 4 INDOOR UNIT RUN GND 5 When a wire...

Page 7: ...er 10h 1h increasement after each press If cancel this NAME AND OPERATION OF THE BUTTON ON THE WIRE CONTROLLER AUTO COOL DRY HEAT FAN TIMER TEMP RESET LOCK MODE FAN 0 TURBO DIRECT ON OFF BUTTON AJUDST...

Page 8: ...tton in cooling mode the fan speed will increase available to some model with powerful function If press this button in heatmode electrical heater function become ineffective 7 Reset button hidden Use...

Page 9: ...turns into horizontal swing mode press it again to quit 14 Lock button hidden When you push the LOCK button all current settings are locked in and the wire controller does not accept any operation exc...

Page 10: ...ion lamp on it works in dry mode Press ON OFF button again it stops to work 4 In dry mode economy operation and fan speed are ineff ective COOL HEAT FAN MODE OPERATION DRY OPERATION can not be changed...

Page 11: ...mer on time as the corresponding step1 and 2 2 Set timer off time as the corresponding step1 and 2 3 Timer off time must be longer than timer on time 4 0 5 second after setting the wire controller sen...

Reviews: