Owner’s & Installation manual 

This manual 

4.    FITTINGS

Please check whether the following fittings are of full scope. If there are some spare fittings , please restore them carefully 

.  

Four-way Cassette 

Four-way Cassette 
       (compact) 

INSTALLATION FITTINGS 

Tubing & Fittings 

Remote controller & Its Frame 

Drainpipe Fittings 

Others 

SHAPE 

NAME 

5. Soundproof / insulation sheath 

8. Out-let pipe clasp 

7. Out-let pipe sheath 

6. Out-let pipe pipe 

9. Tightening band 

14. Installation&owner's manual 

15. Remote controller manual 

10. Remote controller 

11. Frame 

12. Mounting screw 
(ST2.9×10-C-H)  

13. Alkaline dry batteries (AM4) 

3. Installation paper board         

4. Bolt  M6 

1 1 

INSTALLATION FITTINGS 

SHAPE 

NAME 

1. Expansible hook 

2. Installation hook 

 

Four-way Cassette 

 

Four-way Cassette 
       (compact) 

4.2   Local purchased components 

4.1   Attached fittings

4.1   Attached fittings

4.1   Attached fittings

Summary of Contents for IC4H-04KF-3

Page 1: ...MAN ICC4H 1112 Compact Four Way Cassette Chilled Water INSTALLATION OWNER S MANUAL www intensity com mx IC4H 04KF 3...

Page 2: ...ries parts and specified parts for installation otherwise it will cause the set to fall water leakage electrical shock and fire The appliance must be installed 2 3m above floor The appliance shall not...

Page 3: ...all the indoor and outdoor units power supply wiring and connecting wires at least 1 meter away from televisions or radios in order to prevent image interference or noise Depending on the radio waves...

Page 4: ...n sheath 8 Out let pipe clasp 7 Out let pipe sheath 6 Out let pipe pipe 9 Tightening band 14 Installation owner s manual 15 Remote controller manual 10 Remote controller 11 Frame 12 Mounting screw ST2...

Page 5: ...ceiling are even The body s lower part should sink into the ceiling for 10 12 mm refer to fig 5 6 In general L is half of the screw length of the installation hook refer to fig 5 6 Locate the air cond...

Page 6: ...g point of drain pipe 840 Body 950 Panel 330 Drain side Drain side Drain side Tubing side Unit mm Unit mm Unit mm 780 Hook location 780 Hook location 780 Hook location 840 Body 840 Body 840 Body 950 P...

Page 7: ...ers to choose Type H mm Four way cassette Four way cassette compact 45 50 Height of the front panel Ceiling 600mm ceiling hole Ground 261 213 Panel Inlet Outlet Outlet Water pipe joint Connecting poin...

Page 8: ...THE DRAIN PIPE 7 6 1 Install the drain pipe of indoor unit 1 The drainpipe can use PVC pipe external diameter about 37 39mm inner diameter is 32mm 2 Joint drainpipe connector to the end side of water...

Page 9: ...her equipment has to be connected with this power line For detailed installation acceptance please refer to your power supplier if restrictions do apply for products like washing machines air conditio...

Page 10: ...The ground wiring is connected correctly The length of the tubing has been recorded The power voltage fits the rated voltage of the air conditioner There is no obstacle at the outlet and inlet of the...

Page 11: ...ds the middle simultaneously as indicated in fig 9 1 Then pull down the air in grill The control box cables which are originally connected with the main body electrical terminators must be pulled off...

Page 12: ...s in order to shelter from sunshine Reduce heat source AC cooling capacity reduces normal Check leakage Symptoms Causes Unit does not start Air flowing normally but completely can t cooling Units star...

Page 13: ...f the remote controller to the infrared signal receiver of the indoor unit and then repeatly push the ON OFF button twice The indication on the display disappears after a lapse of time Check whether t...

Page 14: ...O Malfunction running lamp timer lamp defrosting lamp alarm lamp 1 2 3 4 5 Room temperature sensor checking channel is abnormal Evaporator sensor checking channel is abnormal EEPROM malfunction Water...