DIAGNOSTIC
DISPLAY 1
POWER
The POWER diagnostic LED illuminates green when power is active at the module.
It will illuminate red during fault conditions.
DATA
The KEYPAD diagnostic LED illuminates green when a keypad is connected to the
module. It will flash blue when any button is pressed on the keypad to show
communications are present.
CAN-BUS
The CAN-BUS diagnostic LED illuminates green when there are active
communications to an external CAN-Bus. It will flash blue when it recognises
a monitored message.
INPUTS
1-6
(Digital)
The INPUT 1-6 diagnostic LEDs illuminate green when the corresponding input is
present.
INPUTS
7-8
(Analog)
The INPUT 7 & 8 diagnostic LEDs illuminate green, amber and red to signify the
pre-programmed voltage thresholds of these inputs. This is set in the GUI.
OUTPUTS
The OUTPUT diagnostic LEDs illuminate green when the output is active.
If there is a short-circuit on an output, the LED will flash off for 500ms and back on
for 500ms continuously until a module power-cycle. The output will shut down
completely and the green power LED will turn red to indicate a present fault.
If the output is in overload condition (>8A), the output will temporarily shut down and
attempt to turn on 3 times. If the output is still in overload condition, the output will
remain shut down until the logic to activate is cycled. During this period, the power
LED will turn red and the output LED will flash fast.
DATA