DIAGNOSTIC

DISPLAY 1

POWER

The POWER diagnostic LED illuminates green when power is active at the module.
It will illuminate red during fault conditions.

DATA

The KEYPAD diagnostic LED illuminates green when a keypad is connected to the
module. It will flash blue when any button is pressed on the keypad to show
communications are present.

CAN-BUS

The CAN-BUS diagnostic LED illuminates green when there are active
communications to an external CAN-Bus. It will flash blue when it recognises
a monitored message.

INPUTS
1-6
(Digital)

The INPUT 1-6 diagnostic LEDs illuminate green when the corresponding input is
present.

INPUTS
7-8
(Analog)

The INPUT 7 & 8 diagnostic LEDs illuminate green, amber and red to signify the
pre-programmed voltage thresholds of these inputs. This is set in the GUI.

OUTPUTS

The OUTPUT diagnostic LEDs illuminate green when the output is active.
If there is a short-circuit on an output, the LED will flash off for 500ms and back on
for 500ms continuously until a module power-cycle. The output will shut down
completely and the green power LED will turn red to indicate a present fault.
If the output is in overload condition (>8A), the output will temporarily shut down and
attempt to turn on 3 times. If the output is still in overload condition, the output will
remain shut down until the logic to activate is cycled. During this period, the power
LED will turn red and the output LED will flash fast.

DATA

Summary of Contents for iConnex

Page 1: ...Page 1 USER MANUAL V2 0 08 10 21 Technical Helpline 44 0 151 482 8970 www intellitecmv com E11 10R05 01 11558 E11 10R05 01 11558 DATA ...

Page 2: ...n be easily retrieved for any future referral Installation must be carried out by competent personnel with adequate knowledge of electrical installations All necessary precautions must be taken to ensure this product is fitted correctly securely and safely into the desired application This product must not interfere with road safety or OEM safety systems fitted to the vehicle All necessary checks ...

Page 3: ...p20 367g 135x165x49 INPUTS OUTPUTS 6x Digital Pos Neg Configurable 2x Voltage Sense Analog 1x Temperature Sense 1x External CAN Bus 9x 8A Positive FET w auto shutdown 1x 1A Negative FET w auto shutdown 2x 30A Relay Dry Contacts COM NC NO CAN Bus Baud Rates 50 Kbits s 83 33 Kbits s 100 Kbits s 125 Kbits s 250 Kbits s 500 Kbits s 19 mA 29 mA Sleepmode Current Consumption mA ...

Page 4: ...N Schematic 87 87A 30 87 87A 30 30A 30A 2mm Positive Supply 2mm Positive Supply Relay 11 Normally Open Relay 12 Normally Open 50A 10mm Positive Supply Input Connector Output Connector Auxiliary Connector Keypad Connector ...

Page 5: ...4 0V Ground to chassis negative 5 0V Ground to chassis negative 6 Input 5 Hi Lo configurable 7 Input 4 Hi Lo configurable 8 Input 3 Hi Lo configurable 9 Input 2 Hi Lo configurable 10 Input 1 Hi Lo configurable 1 Temperature sensor ground 2 Battery voltage sense 1 3 Temperature sensor data 2 4 Battery voltage sense 2 5 Temperature sensor only 3V3 6 Temperature sensor data 1 7 External CAN Hi Vehicl...

Page 6: ...t is present INPUTS 7 8 Analog The INPUT 7 8 diagnostic LEDs illuminate green amber and red to signify the pre programmed voltage thresholds of these inputs This is set in the GUI OUTPUTS The OUTPUT diagnostic LEDs illuminate green when the output is active If there is a short circuit on an output the LED will flash off for 500ms and back on for 500ms continuously until a module power cycle The ou...

Page 7: ...mn on output LEDs 1 6 will illuminate green with a single red LED that flashes vertically to indicate programming mode is active The column on output LEDs 7 12 will illuminate green with a single red LED that flashes vertically when data is being transferred After programming is complete the LEDs will return to normal functionality as described on page 6 Diagnostic Display 1 DATA ...

Page 8: ...Page 8 GUI iConnex GUI is the utility used to write and upload programs to the module It can be downloaded along with programming device drivers from our website www intellitecmv com pages downloads ...

Page 9: ...e for active modes 0 1 2 3 4 5 6 7 8 9 A B C D E F Master Module Slave Module 1 Slave Module 2 Slave Module 3 Slave Module 4 Reserved For Future Use Reserved For Future Use Reserved For Future Use Reserved For Future Use Reserved For Future Use Reserved For Future Use Reserved For Future Use Reserved For Future Use Reserved For Future Use Reserved For Future Use Reserved For Future Use ...

Page 10: ...ge 10 PROGRAMMING The module can be programmed using the new USB B connector The module will automatically enter programming mode when the GUI attempts to program the module via this USB connection USB B ...

Page 11: ... at the iConnex module location these can be enabled by selecting the jumper position accordingly CAN Bus Termination Resistor Jumpers iConnex Data CAN Bus Termination Resistor Jumper External CAN Bus Termination Resistor Jumper One Leg Jumper off Resistor Disabled Two Legs Jumper on Resistor Enabled ...

Page 12: ...ed SWITCH 1 SWITCH 5 SWITCH 6 SWITCH 1 SWITCH 2 SWITCH 3 SWITCH 4 SWITCH 1 SWITCH 2 SWITCH 3 SWITCH 4 SWITCH 1 SWITCH 2 Press switch 1 to move to the next address pattern The number of times the switch 1 LED flashes for a short burst indicates the address number selected When on address 5 pressing the switch 1 button again will revert the address number selected to address 1 The 120ohm termination...

Page 13: ...2 SWITCH 3 SWITCH 4 SWITCH 5 SWITCH 6 The iConnex system installation can be expanded to up to 5 modules and 5 keypads That s a total of 40 inputs 60 outputs and 30 keypad buttons The modules and keypads communicate on the same data network by wiring the keypad connector wiring in parallel The additional iConnex modules need to be addressed to their own unique number Please see page 8 on how to do...

Page 14: ...All keypads are equipped with RGB LED momentary push button switches which have dual intensity capability They also have a programmable RGB status LED in the centre All keypads aremade from robust hard wearing silicon All iConnex keypads are IP66 and can be mounted externally Customer logos can be requested on order for the dome inserts on the keypads for a small additional cost ...

Page 15: ...Page 15 KEYPAD OLED Series OLED DIN ENG 166 0000 OLED X12 ENG 199 0000 ...

Page 16: ...nnex system using the 3 wire colour code as shown in the above diagram The temperature sensor connects to the auxiliary connector on the iConnex module The pin out is shown on page 5 The iConnex temperature sensor is waterproof and can be mounted internally or externally in vehicle applications Ranging from 55 to 125 degrees celsius the temperature sensor is suitable for most ambient temperature m...

Reviews: