DISPLAY

BUTTONS

MANUAL OPERATION

ACTIVITY TIMER

GEN SET ACCESS

The

can display the time of day, battery voltage, generator run time, and the air conditioner

thermostat position.

To scroll through the different displays, press either the “UP” or “DOWN” buttons.

The

corresponding LED indicator will illuminate to let you know which mode you are viewing.

Generator Logic Control

-

To manually start or stop the generator, press and release the START/STOP button. When starting, the
generator will crank the starter for 5 seconds. If the generator does not start, it will attempt again. If the
generator does not start after the fifth attempt, the display will read “GEN FAIL”.

When the generator is started, a timer is started in the controller. The timer counts down from 24 hours. If at the
end of 24 hours, no activity has been observed on the coach, the controller will exit from auto mode and the
generator will stop. If activity has occurred, the controller will stay in auto mode. This is a safety feature in the
event that the auto mode has been left on unintentionally. Many manufacturers use a switch at the entrance
door, which will operate as the door is opened and closed to tell the controller that there is activity. The time
remaining on the activity timer can be observed by pressing the up down buttons until “TMR” is illuminated.

If the generator access door is open, the auto start feature is disabled and the display will flash “

”.

TIME
STOP TIME

.

START TIME

START/STOP

button displays the current set time.

button displays the time of day the generator will automatically shut off if pressed. Pressing it

once activates the auto shutoff

Pressing it a second time turns the auto shutoff off. When auto shutoff is

active, the button will be illuminated.

button displays the time the GLC will go into “AUTO” mode. Pressing the button once turns it

ON and another press turns it OFF. When active, the button will be illuminated.

button starts or stops the generator with a single push

depending on the state of the generator. If

, the button will turn the generator

f

, the button will

turn the generator

. When the generator is

, the light just above the button will illuminate.

button puts the GLC into auto start mode. When in this mode the generator will start if the air

conditioner calls for cooling or the battery voltage gets too low. The button will illuminate whenever in auto
start mode. To turn OFF auto start mode, press the button until light is no longer ON.

OFF

ON. I ON

OFF

ON

AUTO

(do not hold the button down)

DOOR

DIP SWITCH SETTINGS

Set dip switch 1 and 2 for (S11) as follows:

1

ON

Diesel

3

Not Used

OFF Gas

4

Not Used

2

ON

Pulse Crank

OFF

5 second Crank

SPST

DIP

4

S

WITCH

SPST

DIP

4

SWITCH

ON

OFF

1

2

3

4

OPERATING GUIDE

131 Eisenhower Lane North

Lombard, IL 60148

630.268.0010 / 1.800.251.2408

Generator Logic Control

P/N 53-00859-100 Rev. B 050405

www.intellitec.com

Intellitec