200 AMP BATTERY DISCONNECT

Trouble Shooting

Problem

Relay won't engage

Relay won't disengage

Light on panel remains on although relay is off.

Light is off although relay is on

BD1 No voltmeter reading

Possible
Cause/Solution

Check fuses on relay

Check battery voltage, must be greater than 10.5
volts.

While switch is engaged, check for voltage across
the coil terminals (+ on the ""I" terminal and ground
on the "S" terminal). If 0 volts, replace panel, if +
voltage, replace relay.

Check wiring

Check fuses on relay

Check battery voltage, must be greater than 10.5
volts

While switch is engaged, check voltage across the
coil terminals (+ on the "S" terminal and ground on
the "I" terminal). If 0 volts, replace panel, if +
voltage, replace relay.

Check wiring

Is coach plugged in?  Unplug coach

Is engine running?  Turn engine off

Check wiring

Check fuses on relay

Check wiring

Replace panel assembly

Check fuses on relay

Check wiring

Check voltage on green wire. If + voltage, replace
panel