background image

1485 Jacobs Rd.

Deland, FL 32724

386.738.7307

P/N 53-00803-400 Rev. C 041519

www.intellitec.com

Intellitec

SERVICE MANUAL

50 AMP TRANSFER RELAY DELAY

-

DUAL INPUT GENSET

1

CAUTION

Tools Required:

The 50 Amp Transfer Relay connects the power from the shore cord or the generator to the coach's
distribution panel. Power from both these sources is fed into the box. The full power of these sources is
available within this box. Inadvertent shorts inside this box could result in severe damage and/or injury.

Accurate Voltmeter (

).

All servicing within this box should be done only by a qualified Service Technician.

digital read-out preferred

Part Number 00-00803-400

R

LISTED

TR50

US

C

2N52

Transfer Relay Delay 00-00803-400

Dual

Genset

Input

INDUSTRIAL CONTROL EQUIPMENT TYPE 1

Shore Power Rating: 120/240VAC 60HZ 1 Phase 50A/Pole
Generator Rating: 120/240VAC 60HZ 1 Phase 50A/Pole

CAUTION:

RISK OF ELECTRIC SHOCK, MORE THAN ONE DISCONNECT SWITCH MAY BE REQUIRED

TO DE-ENERGIZE THIS DEVICE FOR SERVICING.

ATTENTION:

RISQUE DE CHOC ELECTRIQUE. IL PEUT ETRE NECESSAIRE DE COUPLER

L'ALIMENTATION A PLUS D'UN INTERRUPTER POUR EFFECTUER LE DESAMORCAGE DE CE DISPOSTIF.

WARNING:

TWO SEPARATE POWER SOURCES. REFER SERVICE TO QUALIFIED PERSONNEL.

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, INSTALL IN A CONTROLLED ENVIRONMENT
RELATIVELY FREE OF CONTAMINANTS.

Intellitec

GND

GND

GND

LINE

1

LINE1

LINE1

LINE2

LINE2

NEUT

NEUT

NEUT

GENSET

COACH PANEL

SHORE POWER

CHASSIS GROUND

TORQUE 35 IN-LBS

4-6 AWG

USE STRANDED CONDUCTORS,

RATED FOR 75ºC MIN

COPPER,

FOR SUPPLY CONNECTIONS:

LINE

2

Summary of Contents for 00-00803-400

Page 1: ...2 Transfer Relay Delay 00 00803 400 Dual Genset Input INDUSTRIAL CONTROL EQUIPMENT TYPE 1 Shore Power Rating 120 240VAC 60HZ 1 Phase 50A Pole Generator Rating 120 240VAC 60HZ 1 Phase 50A Pole CAUTION...

Page 2: ...in this box Replacement of a defective box is the only way to correct a failed unit Typical connections for 50Amp service are shown in Figure 3 The connection diagram for this unit is shown in Figure...

Page 3: ...intellitec com Intellitec SERVICE MANUAL 50 AMP TRANSFER RELAY DELAY DUAL INPUT GENSET 3 Cover removed INSIDE VIEW FIGURE 1 FROM GENSET FROM GENSET GND GND LINE1 NEUT GND LINE1 NEUT FROM SHORE POWER F...

Page 4: ...ICE MANUAL 50 AMP TRANSFER RELAY DELAY DUAL INPUT GENSET CHASSIS GROUND GEN LINE 1 BLK GEN NEUT WHITE GEN LINE 2 RED CHASSIS GROUND SHORE LINE 1 BLK SHORE NEUT WHITE SHORE LINE 2 RED CHASSIS GROUND PA...

Page 5: ...litec SERVICE MANUAL 50 AMP TRANSFER RELAY DELAY DUAL INPUT GENSET GROUND LINE 1 BLK NEUT WHITE LINE 2 RED GROUND LINE 1 BLK GROUND LINE 1 BLK NEUT WHITE LINE 2 RED RELAY DRIVE DELAY ELECTRONICS GENER...

Page 6: ...MP TRANSFER RELAY DELAY DUAL INPUT GENSET GROUND LINE 1 BLK NEUT WHITE LINE 2 RED GROUND LINE 1 BLK GROUND LINE NEUT WHITE BLK RELAY DRIVE DELAY ELECTRONICS GENERATOR TYPICAL 30 AMP SERVICE CONNECTION...

Page 7: ...o be sure Measure the voltage from Line 1 to Neutral at the Transfer Relay terminals Check the circuit breakers in the coach distribution box to be sure they are not tripped Reset them to be sure Repl...

Page 8: ...1485 Jacobs Rd Deland FL 32724 386 738 7307 P N 53 00803 400 Rev C 041519 www intellitec com Intellitec SERVICE MANUAL 50 AMP TRANSFER RELAY DELAY DUAL INPUT GENSET 8...

Reviews: