Features

 

 

Support 16 Po rt RS-232/485/422. 

 

Support 10/100M Ethernet. 

 

Support 300bps~ 115200bps baud rate. 

 

Support TC P, UDP, AR P, IC MP, HTTP, DNS and DHCP protoco l. 

 

Support TCP Server, TCP Client, TCP Auto, UDP and Real COM driver working mode. 

 

Support cross-gateway and cross-router communication. 

 

Support TC P/IP SOCKET access. 

 

Support W indows s erial driver mode . 

 

Support virtual serial COM port access and Network interruption automatic recovery. 

 

Provide Windows configuration tools for easy to use, easy to bath install. 

 

Support WEB and  serial configu ration . 

 

No fan, low consumption design. 

 

Industrial grade design, IP30 protection grade. 

 

Working temperature: -25

70

 

Storage temperature: -30

-85

 

 

Panel design

 

 

 

 

 

                                                                              Main view

 

 

IT-SDS-3016-T-16D-16D(RS-232-P(85/265VAC) back view

 

 

IT-SDS-3016-T-16D-16DI(RS-485)-P(85/265VAC) back view 

 

 

 

 

 

 

Summary of Contents for IT-SDS-3016-T-16D Series

Page 1: ...re coming true by WEB or Telnet support cross gateway and cross router user can can flexible configure IP address server and client mode data bag size etc IT SDS 3016 T 16D series adopts EMC protection design can work in rugged environment Packing list The first time use this product please check the packaging is intact or not and the attachment is complete or not at first IT SDS 3016 T 16D series...

Page 2: ...P SOCKET access Support Windows serial driver mode Support virtual serial COM port access and Network interruption automatic recovery Provide Windows configuration tools for easy to use easy to bath install Support WEB and serial configuration No fan low consumption design Industrial grade design IP30 protection grade Working temperature 25 70 Storage temperature 30 85 Panel design Main view IT SD...

Page 3: ...product series 2 Electrical port connection indicator 3 Device running status indicator 4 Power PWR indicator 5 Serial port running indicator 6 Default factory DEF button 7 Power input port 8 Serial port COM1 COM16 9 10Base T 100Base TX Ethernet port ...

Page 4: ...supply input port the range is 85 265VAC Important notice 1 Power ON operation Please connect to the device at first and then connect to the power supply with power cable 2 Power switch means power ON O means power OFF 3 Power OFF operation Please disconnect the power supply at first and then disconnect the device ...

Page 5: ...ponding connection in MDI 1 3 2 6 3 1 6 2 are used as cross wiring in the MDI X port of Converter and HUB 10Base T 100Base TX are used in MDI MDI X the define of Pin in the table as below NO MDI signal MDI X signal 1 TX RX 2 TX RX 3 RX TX 6 RX TX 4 5 7 8 Note TX Transmit Data RX Receive Data Not use MDI straight through cable MDI X Cross over cable MDI MDI X Self adapt function can let user did no...

Page 6: ...nsmit data 2 RXD Received Data 3 RTS Request to send 4 CTS Clear to send 5 DSR Data set ready 6 GND Signal ground 7 DTR Data terminal ready 8 DCD Data carrier detect IT SDS 3016 T 16D 16DI RS 485 P 85 265VAC RS 485adopts 5 bit 5 08mm terminal block The PIN define is as follows RS 485 port PIN Define 1 D A 2 D B 3 GND 4 5 RS 422 port PIN PIN define 1 T A 2 T B 3 GND 4 R A 5 R B 1 8 ...

Page 7: ...lashing In receiving data RX1 RX16 OFF None data transmit Flashing In transmitting data Installation Before installation confirm that the work environment meet the installation require including the power needs and abundant space Whether it is close to the connection equipment and other equipments are prepared or not 1 Avoid in the sunshine keep away from the heat fountainhead or the area where in...

Page 8: ...n they are in the same groove road When cable is too long it cannot hold down other cable but structure in the middle of alignment rack 8 Pigtail cannot be tied and swerved as less as possible Swerving radius cannot be too small small swerving causes terrible loss of link Its banding should be moderate not too tight and should be separated from other cables 9 It should have corresponding simple si...

Page 9: ... 220VAC IT SDS 3016 T 16D 16DI RS 485 P 85 265VAC No load consumption 8 8W 220VAC Full load consumption 10 1W 220VAC Mechanical Shell IP30 protection metal shell Installation 1U 19 rack mount Weight 2500g Size L W H 441 6mm 207 9mm 44 6mm Environment limits Working temperature 25 70 Storage temperature 30 85 Relative humidity 5 95 non condensing Standards EMI EN 55022 Class A FCC Part 15 Subpart B...

Page 10: ...10 Vibration IEC 60068 2 6 Warranty Warranty time 5 years Certificates CE FCC RoHS UL508 pending ...

Reviews: