8

 

 

DIN-Rail Installation 

 

 

 

Troubleshooting instructions: 

1. Make sure the power is connected and turned on.   

2. Make sure the converter Ethernet and fiber optic cables are 

connected properly.   

3. Check the connections according to the connection diagram.   

4. Check the LED Indication status and identify possible problems 

from the Indication LED table above.   

 

Note: 

1. Media  Converter is  a sensitive electronic item,  please  do   

han dle  with  extra care on delivery, shifting and hum idity. 

2. This unit will be warranty for 5 years. 

3. W henever there is a problem regarding the qu ality issue with in 

the warranty period, we will take the responsibility to repair with 

free. 

4. After the  warranty period,  we  will  charge accordingly 

depending on the fault or dam age. 

 

Summary of Contents for IT-PMC-3012

Page 1: ...0Base TX 1000Base T and 1000Base SX LX IT PMC 3012 can conduct mutual conversion between 10Base T 100Base TX 1000Base T twisted pair electrical signals and 1000Base SX LX optical signals This media co...

Page 2: ...19 14 slots Rackmount power external Pinout Configuration Power IT PMC 3012 adopt the power supply input is 5VDC external Ethernet RJ45 Optical fiber interface Optical fiber interface Optic fiber int...

Page 3: ...terface SC is look the same to Mode3012MM SC Ethernet interface Ethernet RJ45 interface supports MDI MDI X auto negotiation can use straight through cable connect PC or server use across over connect...

Page 4: ...TX RX 2 TX RX 3 RX TX 6 RX TX 4 5 7 8 Note TX Transfer data RX Receive data None MDI MDI X 1 8 1 8 RJ45 TX TX TX RX RX RX RX TX 2 3 6 1 2 3 6 1 1 8 RJ45 TX TX TX RX RX RX RX TX 2 3 6 1 6 1 2 3 TX RX...

Page 5: ...plex Mode OFF Half Duplex FLASHING Full Duplex TP TX Ethernet Port OFF Ethernet is not Connected FLASHING Transmitting or Receiving Data BRIGHT Ethernet is Connected Specifications Standards comply wi...

Page 6: ...supply External 5VDC input Dimensions 94 0mm 71 0mm 26 0mm Installation support DIN Rail installation Operating temp 10 C to 65 C Storage temperature 20 to 70 C Operating humidity 5 to 95 no condensat...

Page 7: ...7 Wall mounting installation...

Page 8: ...tion status and identify possible problems from the Indication LED table above Note 1 Media Converter is a sensitive electronic item please do handle with extra care on delivery shifting and humidity...

Page 9: ...ctor tube 3 Correct power supply line connection 4 Returned to the manufacturer for repair 2 FX Fiber Link Port indicator lamp not lighting Cause Optic fiber port link is fault Solution 1 Check fiber...

Page 10: ...cturer for repair 4 Network packet loss Solution 1 Check Ethernet rate or full half duplex is matched or not 2 Ethernet RJ45 port is loose contact or optic port is loose contact and soiled 3 Ethernet...