Intellisystem IT-7304-PC User Manual Download Page 3

 

 

2

 

1. Introduction 

IT-7304-PC  is  a  high-performance  V.35  optic  fiber  modem  developed  by  using  a  dedicated 
integrated  circuit.  It  is  to  modulate  an  N×64K  V.35  data  signal  directly  over  single-  or 
multi-mode  optic  fiber  for  a  transmission  via  optic  cable  line.  At  another  end  of  the  optic 
cable,  optical  signal  is  demodulated  into  a  V.35  data  signal.  V.35  interface  may  be  directly 
connected with  the  V.35 interfaces  of image and data terminals  or the WAN ports of MUX, 
exchanger and router for a dedicated network setup or a LAN connection.   

2. Product Features 

 

Rate N×64Kbit/s (N=1

32) 

 

Support the loopback of local analog/digital interface 

 

Support remote loopback function 

 

Support pseudo-random code test function 

 

120km trunking -free transmission distance for single-mode optic fiber 

 

Capable to be communicated with FE1 Fiber Modem 

 

Available with complete line detection and alarm indications 

 

Available  with  independent  structure  and  19-inch  Rack-mountable  structure 
Rack-mountable structure can be inserted with 16 modules 

 

AC 220V and DC –48V inputs may be selected for fiber optic modems of both structure 

 

For Rack-mountable fiber optic modems,  dual  power supply heat  backup  is  provided to 
ensure a high operating reliability 

3. Specifications 

Optic interface:   

 

Line mode type: CMI   

 

Line mode rate: 2.048Mbps   

 

Operating wavelength:850nm,1310nm or 1550nm   

 

Optic fiber connector: SC/PC   

 

Applicable optic fiber: multi-mode, single-mode   

 

Transmission distance: 

Single-mode: up to 120km Multi-mode: up to 2km   
 

V.35 interface

 

 

Data rate: N×64Kbps 

N=1~32

 

 

Available with CTS/RTS (Hardware) flow control function   

 

Type of connector: M34 connector 

 

Operating mode: DCE   

Indicator lamps: To indicate the operating status of power supply, data receiving/sending, 
loopback and random code test, code missing alarm, out-of-frame alarm etc.   
 
 

Summary of Contents for IT-7304-PC

Page 1: ...IT 7304 PC V 35 Optic Fiber Modem User Manual...

Page 2: ...pplication 6 5 1 Definition of signal lines at V 35 interface 6 5 1 1 Distribution diagram of guiding feet on M34 cored jack 6 5 1 2 Definition of signal lines at V 35 interface 6 5 2 Standard V 35 cr...

Page 3: ...nicated with FE1 Fiber Modem Available with complete line detection and alarm indications Available with independent structure and 19 inch Rack mountable structure Rack mountable structure can be inse...

Page 4: ...V 35 Fiber Modem IT 7304 PC One V 35 Fiber Modem Operation Manual One power line V 35 Fiber Modem AC Please also contact our representative offices or agents for any transportation damage found with t...

Page 5: ...ber with TX as the sending terminal and RX as the receiving terminal There is a coded switch S5 on the panel which is used as the system configuration switch to set such functions as clock time slot p...

Page 6: ...48V power supply connector The others are the same as AC Rear Panel 4 3 Front Rear panels of Rack mountable casing RACK front panel Front Panel of RACK 5V 5V main power supply indicator lamp 12V 12V...

Page 7: ...cy Power Supply Panel 40 60 VDC DC 48V input connector FG grounded with terminals connected with 48V input ON OFF power switch 5V 5V main power supply indicator lamp 12V 12V fan power supply indicator...

Page 8: ...ion output H DTR data terminal ready input P TXD A transmitting data line A input S TXD B transmitting data line B input R RXD A receiving data line A output T RXD B receiving data line B output U EXT...

Page 9: ...m the clock S5 1 OFF S5 2 ON the sending timing is optic interface receiving timing and the received data after buffering is synchronized with optic interface receiving timing Under this timing mode l...

Page 10: ...nt all time slots of E1 are used for transmitting the data from V 35 interface at a rate of 2048Kbps Through a transmission of loopback command from local device to remote device the command remote lo...

Page 11: ...switches to OFF indicates that 6th and 7th time slots are selected with a rate of 2 64K 128K TS0 setting is used for specifying E1 frame to be transparent or framing 0 framing 1 non framing But the b...

Page 12: ...not well inserted 3 Wrong clock setting 4 Time slots of the devices at two ends not conformance 5 Internal circuit damaged 1 Clean the connector of optic interface 2 Insert the SC connector in place...

Reviews: