Intellisystem IT-7301-PC User Manual Download Page 6

 

 

5

 

 

4.2 Front/rear panels of an independent casing   

 

 

IT-7301-PC front panel

   

 

 
 

Front panels of IT-7301-PC 

 

POWER

Power supply indicator lamp. Constantly lightening after the machine is turned on.   

E1  LOF

Alarm  indicator  lamp  for  input  signal  out-of-frame  in  E1  line.  Constantly  lightening  indicates  the 

alarm  with  local  device;  flash  indicates  the  alarm  with  opposite  device.  Alarm  status  of  opposite 

device can be detected only at framing mode.   

E1 LOS

Alarm indicator lamp for code missing in E1 line. Constantly lightening indicates the alarm with local 

device.   

FO  LOF

Alarm  indicator  lamp  of  input  signal  out-of-frame in  optic  line. Constantly  lightening  indicates  the 

alarm  with  local  device;  flash  indicates  the  alarm  with  opposite  device.  Alarm  status  of  opposite 

device can be detected only at framing mode.   

FO LOS

Alarm indicator lamp for code missing in optic line. Constantly lightening indicates the alarm with 

local device.   

LOOP

Indicator  lamp  of  loopback  test  status.  When  local  device  is  at  a  loopback  status,  the  lamp  is 

constantly  lightening;  when  opposite  device  is  at  a  loopback  status,  the  lamp  flashes.  When  local 

device is not at a framing mode, it is unable to detect whether opposite device is at a loopback test 

status.   

PTOK/CRC

Indicator  lamp  of  Pseudo-random  code  test.  When  the  device  is  at  a  loopback  status, 

pseudo-random code test can be made. If this lamp is constantly lightening, it indicates that Pseudo-random 

code passes the test.   

 

 

  IT-7301-PC

/AC rear panel

   

IT-7301-PC/AC Rear Panel Schematic 

220V AC

  AC power jack.   

OFF ON

  Power switch. When the ON button is pressed down, the power supply is turned on.   

E1-

75Ω TX

RX

Receiving/sending jack of 75ΩBNC interface in E1.   

E1-

120Ω

 

Jack of 120Ω RJ45 interface in E1.   

TX RX: Receiving/sending jack of optical fiber, with TX as the sending terminal and RX as the receiving 

terminal. 

   

220V  AC

OFF      ON

TX

RX

E1-75?

TX

RX

E1-120 ?

220V  AC

OFF      ON

TX

RX

TX

RX

E1-75?

TX

RX

E1-120 ?

E1-75?

TX

RX

E1-120 ?

1   2   3   4   5   6   7   8

ON

P

A

T

T

O

F

F

O

F

F

O

F

F

O

F

F

ON

R

L

O

O

P

D

L

O

O

P

L

L

O

O

P

T

IM

_

M

O

D

1

T

IM

_

M

O

D

0

T

IM

_

M

A

S

K

Summary of Contents for IT-7301-PC

Page 1: ...User Manual IT 7301 PC...

Page 2: ...ersion upgrades or other reasons this document is subject to change without notice Unless other agreement this document only as a guide to use all statement information and suggestion in this document...

Page 3: ...FRONT REAR PANELS OF AN INDEPENDENT CASING 5 4 3 FRONT AND REAR PANELS OF RACK MOUNTABLE CASING 7 5 IT 7301 PC APPLICATION 9 5 1 E1 CONFIGURATION 9 5 2 CONNECTION THE TWISTED PAIR 120 OHM TO THE G 703...

Page 4: ...tic Support the loop back of local analog digital interface Support pseudo random code test function providing convenience for the test of optic fiber line status 120km trunking free transmission dist...

Page 5: ...60V AC input 5V 16A 12V 1A output 38V 58V DC input 5V 16A 12V 1A output Power consumption 3W Operating temperature 0 50 Storage temperature 20 80 Humidity 5 90 free of condensate 4 Description on Inst...

Page 6: ...cal device LOOP Indicator lamp of loopback test status When local device is at a loopback status the lamp is constantly lightening when opposite device is at a loopback status the lamp flashes When lo...

Page 7: ...me slot setting valid only when S5 1 OFF S5 2 ON S5 3 ON using local time slot setting S5 4 Reserved S5 5 Local loopback setting optic interface in direct loopback ON valid S5 6 Local digital loopback...

Page 8: ...nel is a group of indicator lamps matrix PWR power supply lamp RXD lightening upon data receiving TXD lightening upon data sending LOS lightening when either optic line or E1 line gets lost LOF lighte...

Page 9: ...160 270 VAC AC 220V input jack ON OFF power switch 5V 5V main power supply indicator lamp 12V 12V fan power supply indicator lamp RACK DC redundancy power supply panel RACK DC Redundancy Power Supply...

Page 10: ...ng is synchronized with E1 port timing Optic interface receiving timing optic interface originated from the clock S5 1 OFF S5 2 ON the sending timing is optic interface receiving timing and the receiv...

Page 11: ...2048Kbps Through a sending of loop back command from local device to remote device the command remote loop back is achieved Remote Loop back S5 8 Pseudo random code test control PATT OFF indicates nor...

Page 12: ...ce 3 Refer to the description on rear panel 4 Returned to the manufacturer for repair 3 Optic LOS data loss alarm lamp lightening 1 Optic fiber in wrong interconnection 2 Optic fiber not well inserted...

Reviews: