IntelliSense SECURIT 900C User Manual Download Page 5

5

FIRE

The Alarm Company may have linked smoke detectors to the control
panel.  If activated the sounders will pulse.  

Make sure that every one

leaves the premises

.  When you are sure that it is safe to return,

proceed directly to keypad enter the user code.  The sounders will stop.
Refer to page 7 to reset the alarm.

USER FUNCTIONS & OPTIONS

CODE CHANGE

The system has 8 user codes.  The default user 1 code is 

1

-

2

-

3

-

4

. There

may be times that you need to change your user code.  To help you
remember your new code, write it down 

before

 changing it and after you

have successfully changed and memorised the code destroy the written
code. Remember, try not to use obvious codes such as  the current year,
1-1-1-1 etc.

To change

 user code 1

, enter your existing code then press 

8

, followed

by

 1

 for user 1.  Enter your new 4-digit code the keypad will give two

beeps.

If the panel does not accept your code then there may be a conflict with
another user code.  The panel will abort the code change and retain the
old code.  Three beeps will be heard from the keypad.  Try again with a
different code.

To change

 user 2 code

 go through the above procedure but press

 8

,

followed by 

2

 for user 2, then the required code.  The other users are

changed in the same way using 

existing code

,

 8

,

 user number

,

 new

code

.

User code access levels

 User 1 code can alter all user codes

 Other users can only alter their own code

 All codes have the same access authority

 Code 8 is reserved for Duress

If for any reason you forget or mistype your master code (user 1) when
changing it, the Alarm Company will need to be contacted to reset the
panel codes.

DURESS

User code 8 is reserved to be enabled by the Alarm Company as a duress
code.  When used it will operate normally as all other codes but will also
send a silent duress signal to the alarm monitoring station, see page 7.
USE WITH CARE.

FIRE

CODE  CHANGE

USER CODE
ACCESS
LEVELS

DURESS

Summary of Contents for SECURIT 900C

Page 1: ...USER MANUAL SECURIT 900C CONTROL PANEL ...

Page 2: ...iceable parts inside this product STANDARDS This unit conforms to EMC directive 89 336 EE LVD 73 23 EEC R TTE CTR21 This unit has been tested to the required standards for emission immunity and LVD regulations as set out by the EU This unit conforms to the requirements of BS 4737 part 1 1986 which relates to security control equipment PRODUCT DESCRIPTION The control panel is an 8 zone programmable...

Page 3: ...med for quick set press 1 to full set the system Selecting Part Set Enter user code and press 2 If your system has been programmed for quick set press 2 to part set the system The exit sounds are programmable by the Alarm Company only the fault pulse tone and set acknowledge bleeps may sound Selecting Home Set Enter user code and press 3 If your system has been programmed for quick set press 3 to ...

Page 4: ...mper condition is still present Refer to fault clearing on page 7 PERSONAL ATTACK If your system has a personal attack button fitted this will be linked into the alarm system as a 24hr device The PA button will be active all the time If the PA button is pressed all the sounders will operate and the zone programmed as PA will indicate on the keypad Enter your user code the sounders will stop Go to ...

Page 5: ...eps If the panel does not accept your code then there may be a conflict with another user code The panel will abort the code change and retain the old code Three beeps will be heard from the keypad Try again with a different code To change user 2 code go through the above procedure but press 8 followed by 2 for user 2 then the required code The other users are changed in the same way using existin...

Page 6: ...pad all zones that have responded will be illuminated To Cancel enter a user code and wait for two beeps CHIME The control panel offers the ability to have chime on a zone when unset This feature will emit two beeps via the internal speaker and keypad buzzer whenever a zone is activated To enable chime enter the user code press the 9 key and the number key that represents the zone s you want on ch...

Page 7: ...t Type Tampers Alarms Customer Engineer Technistore Assistance telephone number FAULT CLEARING SYMPTOM CAUSE ACTION Zone LED on continuously Alarm activated Reset the panel Tone pulsing on exit Zone in Fault Leave protected area and wait for tone to go continuous Tone continues to pulse after exit Zone in Fault Check for open doors or a detector is in fault call your Alarm Company Alarm triggers o...

Page 8: ...ONE AREA COVERED 1 2 3 4 5 6 7 8 Please Note IntelliSense are always endeavouring to improve quality and specification of all its products and may alter or amend this product and instructions without notice IntelliSense 2002 Printed Manufactured in the UK by IntelliSense Document No II1 0901 Rev 1 0 ...

Reviews: