BACK FOCUS SCREW ADJUSTING
The external synchronization (Line Lock) switch is set
to
“ON”
position at rhe
factory, The camera will synchronize to the zero crossing of incoming AC
voltage, which is connected to the middle pin of the power connector. Please
ensure that all the input AC voltage connection of the camera are on the same
phase. If the power voltage connection is reversed. the camera will lock at
180^
of the incoming AC voltage. When the wrong connection is found, please make
the correction
for
the zero crossing
purpose.
How
To Use
Auto
Iris
Lens
(a)
Please assemble the Miniature Plug (provided) for the Auto Iris Lens as shown in
the following diagram.
6