IntelliSense FlexGuard-Plus FG-930 Installation Instructions Download Page 1

No adjustment on audio

MOUNTING  PROCEDURE

Orient the unit as shown in Figure 1.  Remove the screw located at its top.

While depressing the latch near the top of the unit, swing the front cover

forward.  Use the back cover as a template to mark holes for the mounting

screws and wiring, then drill the holes.

The unit must have a direct line of sight to, and a clear view of,

the protected glass.

The FG-930 can be mounted on walls, in corners, even on false or suspended

ceilings.  Refer to the guidelines below when selecting a mounting location.

MOUNTING  LOCATION

Locate the FG-930 

within 30'

 (9 m) of the glass to be protected.

Curtains, blinds, and other window coverings will absorb energy

from breaking glass.  Heavy curtains, for example, will effectively

block the sound signal.  In these cases, mount the unit on the

window frame behind the window covering, or above the

window.  

Make sure to test the unit thoroughly for proper

detection

.

Do not mount the unit in front of air ducts or forced air fans, or

close to bells measuring 2" (or larger) in diameter.

Dual flex/audio technology

FEATURES

Separate  microphones  for

audio and flex detection

Energized form C alarm relay

with voltage supervision
RF immunity
Indicator  LEDs

8 - 14 VDC operation
Low 30 mA at 12 VDC current

draw

Advanced acoustic filter to

prevent microphone overload

Cover tamper switch
Noise burst rejection circuit

Adjustment on flex detection

to fit characteristics of each

location

Transient protection

Alarm memory

The FG-930 from IntelliSense is a 

dual technology 

glassbreak detector  that

uses flex detection and audio discrimination to detect breaking glass.

The FG-930 uses separate microphones to sense flex and audio frequen-

cies.   The flex microphone is sensitive to ultra low frequencies, the type

generated by a blow to a glass window.  The audio microphone detects the

higher frequencies of breaking glass.

The flex microphone is also equipped with an advanced acoustic filter for

more stable flex detection.  This filter is specially designed to prevent the

microphone overload caused by very loud sounds.

The FG-930's audio technology remains off until the flex technology detects

a blow to the glass.  For an alarm condition to occur, the audio must detect

the frequency of breaking glass within a defined time-window 

after

 the flex

detects a blow to the glass.

Because both technologies must detect and verify glass breakage, 

false

alarms are virtually eliminated

.

Tamper

Form A (NC)

50 mA, 30 VDC

Power

8 - 14 VDC

30 mA typical at 12 VDC

V+

V-

C

NC

Figure 2 FG-930  Terminal  Strip

NC

C

NO

Alarm

Form C

500 mA max, 24 VDC max,

30 VA max

To adjust the flex technology of the FG-930:

  Use a screwdriver to set the

flex sensitivity control (R5) at MAXIMUM by turning it all the way clockwise.

Refer to Figure 3 on the back side of this page.

Turn on any heating/air conditioning system in the vicinity and observe the

yellow flex LED (DS2) for approximately one minute.  Excessive subsonic

(inaudible) noise typically produced by air handling systems may cause

the flex LED to flash randomly.

If it flashes randomly, turn the R5 control counterclockwise just until the

flashing stops.

FLEX  ADJUSTMENT

For  corner  mounting

(score and pull flap open)

REAR HOUSING

FRONT HOUSING

For  surface  mounting

After removing screw at top of

unit, depress this latch to open

housing

Figure 1 Mounting  the  FG-930

Observing the proper polarity, wire the unit as shown in Figure 2.  (Use 22

to 14 AWG.)  Reverse-polarity connections 

will not

 damage the unit.

WIRING

Wire Entry

Knockouts





Pull the wiring into the unit through the back cover.  Using the two mounting

screws, mount the rear housing at the desired location.

Note:

 If you plan to corner-mount the unit, remove the printed

circuit board 

before

 marking and drilling holes for the mounting

screws.

Tip:

If  mounting  the  FG-930  near  heavy  machinery  or  central  air

conditioning, test the glass-break function before mounting.  Use

a  9  V  battery  for  power,  and  tape  the  sensor  to  the  desired

mounting location.  Refer to the 

Flex Adjustment, Testing the FG-

930,

 and 

Final Testing

 sections to determine which location will be

most suitable.

FlexGuard-Plus

TM

Dual Technology

Glassbreak Detector

INSTALLATION  INSTRUCTIONS

Model

FG-930  30' range max

Reviews: