Intellinet 510486 User Manual Download Page 7

support Spanning Tree or Fast Spanning Tree protocols. By default, 

transmission of data will travel via the primary path. If a link failure is 

detected, transmission will automatically be switched to the secondary 

path by Spanning Tree Protocol, delivering non-stop network connectivity.

 

LEDs

Front panel LEDs provide at-a-glance network status and real-time 

connectivity information. 

NOTE:

 The PWR (power) LED is located on 

the rear panel on some models.

7

LED    Status    Indication                                                                          

100 

  On 

  Data packets are being transmitted at 100 Mbps.

 

  

  Off 

  Data packets are being transmitted at 10 Mbps.*

 

1000    On 

  Data packets are being transmitted at 1000 Mbps.

 

  

  Off 

  Data packets are being transmitted at 10/100 Mbps.*

ACT    On 

  Data is being transmitted/received.

 

ALM    On  

  A failure has occurred on a fiber or copper link.

COL    On 

  Data collisions are occurring.

FD/FDX   On 

  The device (or corresponding link) is operating in full 

 

  

   

    duplex mode.

  

  Off 

  The device (or corresponding link) is operating in half

 

  

   

  duplex mode. 

 

LFS    On 

  A break or disruption exists in copper or fiber links.

 

LNK    On  

  A link has been established with a compliant device.

 

  

  Flashing    Data is being transmitted/received (LNK/ACT combined).

  

  Off 

  No valid link is established to the port.

PRI 

  On 

  The primary link is receiving link pulses from a  

  

   

    compliant device. 

  

  Off 

  The signal has been lost on the primary fiber port.

PWR    On 

  Power is being received for normal operation. 

  

  Off 

  No power is being received.

RCV     On  

  Data packets are being received.

   

  Flashing    Data packets are being received at a slower rate.

   

  Off 

  No data packets are being received. 

RDT    On 

  The redundant link is receiving link pulses from a 

 

  

   

    compliant device. 

  

  Off 

  The signal has been lost on the redundant fiber port.

Applicable with multi-speed models.

Summary of Contents for 510486

Page 1: ...Media Converter user manual Models 510486 510493 510509 510523 515320 515337 515344 515351 515368 519069 INT MEDCON UM 0908 01 Shown Model 515368...

Page 2: ......

Page 3: ...ed Auto MDI MDI X support Status LEDs for easy monitoring of device status External power adapter Lifetime Warranty This user manual is included with the following items 519069 Ethernet Media Converte...

Page 4: ...which case the user may be required to take adequate measures to correct Overview Since all the INTELLINET NETWORK SOLUTIONS Media Converter models represented in this manual do not share all the same...

Page 5: ...DIP switches let you activate both local and remote loopback diagnostic test functions Check for proper cable connections first and run the test with a traffic level of at least 50 percent of capacit...

Page 6: ...for advice IMPORTANT Deactivate both the local and the remote loopback test functions for normal converter operation Link Fault Signaling LFS Link Fault Signaling LFS is an important function that is...

Page 7: ...ed on a fiber or copper link COL On Data collisions are occurring FD FDX On The device or corresponding link is operating in full duplex mode Off The device or corresponding link is operating in half...

Page 8: ...TX Port A 10 100Base TX port supports network speeds of either 10 Mbps or 100 Mbps and can operate in half and full duplex transfer modes The RJ 45 connector is suitable for UTP cable Category 3 4 5 o...

Page 9: ...rk speed of 1 000 Mbps and operates in full duplex transfer mode The RJ 45 connector is suitable for UTP cable Category 5 or better Redundant Gigabit SFP Slot To connect a fiber cable s connector to a...

Page 10: ...e on the port 3 Connect one end of the cable to the SC WDM port on the converter and the other end to the SC WDM port on the other device NOTE When inserting the cable be sure the tab on the plug clic...

Page 11: ...eatly affect its 11 24mm 6mm Try to maintain a bend radius o min 4x the diam of the ca for UTP 100x for Place cable at regular interval s d not over tigh cable ties to avoid usi with fiber 6 mm 24 mm...

Page 12: ...e WARNING Exercise caution if using power tools to install the device Also because invisible laser radiation may be emitted from the aperture of the port when no cable is connected avoid exposure to l...

Page 13: ...nt link converters function as a high speed bridge between switches creating increased capacity for each user node on the local area network and providing a 10 100 1000 Mbps full duplex link to a vari...

Page 14: ...0 Mbps full duplex link to a workgroup of 10 100 1000 switches located on separate floors within a single building Switch Converter Converter Workstation In this configuration the converters function...

Page 15: ...s link for RJ 45 port LINK TX for fiber SFP port ALM indicator for errors on copper or fiber connection PRI Primary Link indicator RDT Redundant Link indicator DIP Switches Link Fault Signaling LFS on...

Page 16: ...45 port 1000 Mbps link for RJ 45 port LINK ACT for fiber SFP port ALM indicator for errors on copper or fiber connection DIP Switches Link Fault Signaling LFS on off Power External power adapter 12 V...

Page 17: ...n power budget 12 dB Max power budget 18 dB Safety EMI certificates FCC Class A CE Mark LEDs Power Full half duplex LINK TX for RJ 45 port LINK TX for fiber SC port DIP Switches DIP 1 Enables disables...

Page 18: ...indicates a break or disruption in copper or fiber links 100 indicates data packets are being transmitted at 100 Mbps DIP Switches DIP 1 Enables disables auto neg DIP 2 Copper port RJ 45 duplex mode f...

Page 19: ...FS indicates a break or disruption in copper or fiber links 100 indicates data packets are being transmitted at 100 Mbps DIP Switches DIP 1 Enables disables auto neg DIP 2 Copper port RJ 45 duplex mod...

Page 20: ...e LFS indicates a break or disruption in copper or fiber links 100 indicates data packets are being transmitted at 100 Mbps DIP Switches DIP 1 Enables disables auto neg DIP 2 Copper port RJ 45 duplex...

Page 21: ...ax TX power 4 dBm RX sensitivity 18 dBm Link budget 8 5 dB Safety EMI certificates FCC Class A CE Mark LEDs Power LINK TX for RJ 45 port LINK TX for fiber SC port DIP Switches N Way on off Power Ext p...

Page 22: ...20 dBm Link budget 10 5 dB Safety EMI certificates FCC Class A CE Mark LEDs Power Full half duplex LINK TX for RJ 45 port LINK TX for fiber SC port DIP Switches N Way on off Power Ext power adapter 12...

Page 23: ...o indicate data collision FDX indicates full duplex mode ACT flashes to indicate data traffic LNK indicates receiving link pulses from compliant device LFS indicates a break or disruption in copper or...

Page 24: ...active and passive networking products Ask your local computer dealer for more information or visit www intellinet network com Copyright INTELLINET NETWORK SOLUTIONS All products mentioned are tradema...

Reviews: