Most modules will come with the cable already connected but it is good to double check the 
orientation. Be aware that some modules may have headers that serve other purposes so 
ensure the cable is connected to the right one. 

The other end of the cable, with a 16-pin 
connector, connects to the power bus board of 
your Eurorack case. Ensure the red stripe on 
the cable lines up with the -12V pins on the 
bus board. On Intellijel power supplies the 
pins are labelled with the label “-12V” and a 
thick white stripe: 

If you are using another manufacturer’s power 
supply, check their documentation for 
instructions. 

 

 

 

Once connected, the cabling between the module and power supply should resemble the 
picture below: 

Before reconnecting power 
and turning on your modular 
system, double check that 
the ribbon cable is fully 
seated on both ends and 
that all the pins are correctly 
aligned. If the pins are 
misaligned in any direction 
or the ribbon is backwards 
you can cause damage to 
your module, power supply, 
or other modules. 

After you have confirmed all 
the connections, you can 

reconnect the power cable and turn on your modular system. You should immediately check that 
all your modules have powered on and are functioning correctly. If you notice any anomalies, 
turn your system off right away and check your cabling again for mistakes. 

 

Page 4 

Summary of Contents for Triatt

Page 1: ...Triatt Manual Triatt Triple Attenuator Inverter Attenuverter Mixer DC Voltage Source Manual Revision 2018 09 13 ...

Page 2: ...Triatt Manual Table of Contents Table of Contents Compliance Installation Installing Your Module Overview Features Front Panel Controls Inputs Outputs Rear Jumpers Technical Specifications Page 1 ...

Page 3: ...h the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to...

Page 4: ...ew module To prevent screws or other debris from falling into the case and shorting any electrical contacts not leave gaps between adjacent modules and cover all unused areas with blank panels Similarly do not use open frames or any other enclosure that exposes the backside of any module or the power distribution board You can use a tool like ModularGrid to assist in your planning Failure to adequ...

Page 5: ...pply check their documentation for instructions Once connected the cabling between the module and power supply should resemble the picture below Before reconnecting power and turning on your modular system double check that the ribbon cable is fully seated on both ends and that all the pins are correctly aligned If the pins are misaligned in any direction or the ribbon is backwards you can cause d...

Page 6: ...nding on the setting of the three position switches Each input is normalled to a DC voltage selectable via jumpers for each channel to be 5V or 10V With nothing plugged into the jacks each knob controls a voltage amount Features Skiff Friendly single PCB 3 modes for each channel 5V or 10V normally to inputs With external signals it acts as active buffered attenuator attenuverter inverter mixer Pag...

Page 7: ...Triatt Manual Front Panel Page 6 ...

Page 8: ...outputs the inverse of the signal at IN A when the knob is fully clockwise and no signal when it is fully counterclockwise For example if the input is 5 V the output will be 5 V with the knob fully clockwise With the switch in the middle position the channel acts a bipolar attenuverter The output is the unmodified input with the knob fully clockwise the inverse of the input with the knob fully coun...

Page 9: ... no cable is plugged in to the input is either 5 V or 10 V depending on the position of the corresponding jumper on the rear of the module D OUT A Output for channel A Plugging a cable into this jack removes the output from the SUM mix E OUT B Output for channel B Plugging a cable into this jack removes the output from the SUM mix F C SUM With no cables connected to OUT A or OUT B this output is a...

Page 10: ... is connected This feature allows the module to be used as a manually variable voltage without needing to apply any input signal When the jumper is between the top and middle pin the voltage at the input is 5 V and when it is between the bottom and middle pin the voltage is 10 V IMPORTANT Ensure the modular system is powered off before changing the jumper setting Page 9 ...

Page 11: ...Triatt Manual Technical Specifications Width 6 hp Maximum Depth 24 mm Current Draw 16 mA 12V 14 mA 12V Page 10 ...

Reviews: