Most modules will come with the cable already connected but it is good to double check the 
orientation. Be aware that some modules may have headers that serve other purposes so 
ensure the cable is connected to the right one. 

The other end of the cable, with a 16-pin 
connector, connects to the power bus board of 
your Eurorack case. Ensure the red stripe on 
the cable lines up with the -12V pins on the 
bus board. On Intellijel power supplies the 
pins are labelled with the label “-12V” and a 
thick white stripe: 

If you are using another manufacturer’s power 
supply, check their documentation for 
instructions. 

 

 

 

Once connected, the cabling between the module and power supply should resemble the 
picture below: 

Before reconnecting power 
and turning on your modular 
system, double check that 
the ribbon cable is fully 
seated on both ends and 
that all the pins are correctly 
aligned. If the pins are 
misaligned in any direction 
or the ribbon is backwards 
you can cause damage to 
your module, power supply, 
or other modules. 

After you have confirmed all 
the connections, you can 

reconnect the power cable and turn on your modular system. You should immediately check that 
all your modules have powered on and are functioning correctly. If you notice any anomalies, 
turn your system off right away and check your cabling again for mistakes. 

 

Page 4 

Summary of Contents for mVCF

Page 1: ...VCF Manual VCF State Variable Filter Manual Revision 2018 09 13...

Page 2: ...VCFManual Table of Contents Table of Contents Compliance Installation Installing Your Module Overview Features Front Panel Controls Inputs and Outputs Instructions Technical Speci cations Page 1...

Page 3: ...the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a...

Page 4: ...module To prevent screws or other debris from falling into the case and shorting any electrical contacts not leave gaps between adjacent modules and cover all unused areas with blank panels Similarly...

Page 5: ...y check their documentation for instructions Once connected the cabling between the module and power supply should resemble the picture below Before reconnecting power and turning on your modular syst...

Page 6: ...ing This is another great David Dixon design offering a very clean and precise lter It responds very well to frequency modulation and the small size makes it an ideal choice for a smaller system Featu...

Page 7: ...e level of the lter input signal The signal is unattenuated when the knob is fully clockwise 5 FM1 Attenuator Attenuates the control voltage of the FM1 input When fully clockwise the input is unattenu...

Page 8: ...ypes and their effect Adjusting the FREQ knob will change the frequency range passed by the lter and increasing the Q knob will add resonance at the FREQ cutoff frequency Now try connecting a modulati...

Reviews: