background image

Quick Reference Guide - Understanding the Blockage Screen

Mass Flow Levels

Displays flow levels of all 

product types.

Work Switch

Indicates if implement is in 

the ground (green) or out of 

the ground (white)

Record Button

Record the mass flow and 

average variance for each 

product for one minute

Guides Button

Access operator’s manual, 

installation guide, and other 

troubleshooting information

Settings Button

Make changes to your air 

seeder configuration in the 

app

Support (US): 701-436-1219 

 

 

       www.intelligentag.com 

 

 

   Support (CAN): 306-993-1156

“Product A” Manifolds (white)

“Product B” Manifolds (blue)

Irregular Product Flow

If flow level is outside of the 

set parameters, the number 

will turn red

Blocked Runs

Individual blocked runs 

become larger and red

Flow Variance

Percentage above/below flow 

average is reported on the 

bottom of each manifold

Irregular Variance

Individual manifolds that 

have variance outside of set 

parameters will turn orange

Section Control Manifold

Manifolds appear dimmed 

when not seeding due to 

section control

Blockage History

View recently detected 

blockages