Quick Reference Guide - Understanding the Blockage Screen
Mass Flow Levels
Displays flow levels of all
product types.
Work Switch
Indicates if implement is in
the ground (green) or out of
the ground (white)
Record Button
Record the mass flow and
average variance for each
product for one minute
Guides Button
Access operator’s manual,
installation guide, and other
troubleshooting information
Settings Button
Make changes to your air
seeder configuration in the
app
Support (US): 701-436-1219
www.intelligentag.com
Support (CAN): 306-993-1156
“Product A” Manifolds (white)
“Product B” Manifolds (blue)
Irregular Product Flow
If flow level is outside of the
set parameters, the number
will turn red
Blocked Runs
Individual blocked runs
become larger and red
Flow Variance
Percentage above/below flow
average is reported on the
bottom of each manifold
Irregular Variance
Individual manifolds that
have variance outside of set
parameters will turn orange
Section Control Manifold
Manifolds appear dimmed
when not seeding due to
section control
Blockage History
View recently detected
blockages