background image

 

14 

Press F1 (EXIT) button to return to the previous option screen and the last setting will 

be saved. 

 

 

Change Door Opening Password 
Manager Setting 

 Door Setting 

 Opening Password 

 

 

 

 

Note: This GSM Door Phone system will allow the user to open door by pressing 6-digit password.    This 

feature is designed for easy access control. We suggest to change the    Door Opening Password every 

month or every two weeks for security concern. 

 

Under the Manager Menu option, press 

CALL button. 

Select Door Setting and press 

CALL button. 

Select Opening Password and press 

CALL button. 

Enter password (must be 6 digits).   

Press 

CALL button to save the new password. 

Press F1 (EXIT) button to return to previous option screen. 

 
 
Door Opening Time 
Manager Setting 

 Door Setting 

 Door Open Time 

 

 

 

Note: This GSM Door Phone system will allow the user to set how long the door lock will be 
opened.    Sometimes, the user might need more time to reach from the door phone unit to the 
locked main gate.    We suggest to set enough time to allow him/her walk in no hurry.   

 

Under the Manager Menu option, press 

CALL button. 

Select Door Setting and press 

CALL button. 

Select Door Open Time and press 

CALL button. 

Enter the number of seconds (from 03 to 99). 

Press 

CALL button to save. 

Press F1 (EXIT) button to return to previous options screen. 

 
 

Door Open Time     
 
03 Second(s) 

Opening Password 
 
Password: 123456 

Intelligent Security & Fire Ltd

Summary of Contents for GSM Door Phone System

Page 1: ...nstallation Setting and Operation Manual User Manual 263 S V1 Please read this user manual completely before operating this system and keep it in a safe place for future reference I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Page 2: ...SETTING Change Microphone Volume Change Speaker Volume Change Speaker Volume During Conversation DOOR SETTING Enable Disable Door Lock Open by Password Change Door Opening Password Door Opening Time CALLING SETTING Set Calling Time Change the Calling by List SUBSCRIBER ID NUMBER SETTING Setup Subscriber ID Number CONTACTING A SUBSCRIBER OPEN THE DOOR REMOTELY GO BACK TO STANDBY SCREEN AUTOMATICALL...

Page 3: ...ver them 5 Do not use this product near an area where there is a potential of gas leaks or near any fumes that can be explosive 6 Do not place this equipment near or over a radiator or any other heat source 7 Use ONLY the power adapter supplied with the system 8 Do not overload the wall outlet or power cord where the power adapter is installed This can result in fire or electric shock 9 This equip...

Page 4: ...nit 1 x AC power adapter 1 x GSM antenna 1 x Wall mounting bracket 1 x Wire 4 x screws for mounting bracket 2 x screws for door phone 1 x User manual Optional Accessories Rain hood Antenna bracket System Diagram Front View I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Page 5: ...lay Keypad 0 9 Number keys F1 Menu Exit key F2 Delete key F3 ABC abc 123 exchange button Volume select up key Volume select down key Microphone Bottom cover System Diagram Back View I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Page 6: ... Opening for connecting wall mount bracket Metal back cover plate Opening for connecting wall mount latch SIM card slot Wiring terminal USB port GSM antenna Bottom cover GSM Antenna socket I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Page 7: ...6 INSTALLATION I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Page 8: ...tion to connect wires and insert the SIM card to SIM card slot as Step 3 shown below 3 Put the bottom cover back as Step 4 shown below 4 Place door unit on the fixed wall mount bracket as Step 6 7 shown below 5 Put the acrylic cover on the door unit when door unit has been screwed as Step 8 9 shown below 6 Plug the AC adapter into the AC outlet then the door unit will go into standby mode I n t e ...

Page 9: ...NING Only use the original power adapter supplied Using any other adapter might damage the door unit and cause a risk of electric shock Wiring Instructions I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Page 10: ...9 I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Page 11: ...to standby mode Turn the power off Turn off the door unit by unplugging the power adapter from the AC power outlet Manager Mode and Functions Note The unit will be time out after 5 seconds if no button is pressed Press F1 MENU button and the system will show Hello Manager Password ______ After entering default password 123456 press CALL button to show the button functions as listed below Press any...

Page 12: ...ess CALL button Select System Setting and press CALL button Select Change Password and press CALL button Enter new password by Number button must be 6 digits Enter password again to confirm and press CALL button Store Manager Phone Number Manager Setting System Setting Manager Phone Note This will be the number that is called when the CALL button is pressed in standby mode Under the Manager Menu o...

Page 13: ...tton to save Press F1 EXIT button to return to previous option screen Volume Settings Change Microphone Volume Manager Setting Volume Setting Mic Volume Note There are 9 levels of sensitivity for the microphone volume going from left least sensitive to right most sensitive If the GSM Door Phone is installed outdoors please set the microphone level to 3 or 4 This may help to reduce picking up too m...

Page 14: ...rsation if the caller needs to increase speaker volume he can press UP DOWN buttons to make adjustment The screen will show the current speaker volume and the microphone will be mute for 1 5 seconds then the conversation will be continued Door Setting Enable Disable Door Lock Open by Password Manager Setting Door Setting Open by Password Note If your GSM Door Phone is connected with an electric do...

Page 15: ...ss CALL button to save the new password Press F1 EXIT button to return to previous option screen Door Opening Time Manager Setting Door Setting Door Open Time Note This GSM Door Phone system will allow the user to set how long the door lock will be opened Sometimes the user might need more time to reach from the door phone unit to the locked main gate We suggest to set enough time to allow him her...

Page 16: ...ow the user to set the calling by list Under the Manager Menu option press CALL button Select Calling Setting and press CALL button Select Calling by List and press CALL button Press button to adjust On or Off for the Calling by List function Press CALL button to save the function Press F1 EXIT button to return to previous option screen Subscriber The Subscriber function supports to set up multipl...

Page 17: ...ursor is moved to N Name position press CALL button and then you can enter the tenant s name by 2 9 Number buttons Use F3 button to select ABC or abc 0 button space button Move cursor to 1 by button and press CALL button to enter Enter the first phone number with area code then press CALL button to save Move cursor to 2 by button and press CALL button to enter Enter the second phone number with ar...

Page 18: ... while dialing pressing F1 Menu Exit or F2 Delete Cancel button will stop the conversation Open the Door Remotely During conversation the called party can press the button to open the door The door open time can be set by user The default setting is 3 seconds Go Back to Standby Screen Automatically If the manager password has been entered and no button is pressed within 30 seconds the screen will ...

Page 19: ...Manager Phone is not stored no action will be taken by pressing the CALL button Master Reset The following operation will make the unit back to factory default Please note that this will erase all passwords phone numbers and subscribers At the Standby mode press F2 C UP UP UP DOWN DOWN DOWN and CALL buttons in sequence It will show Initial System Please Wait then all is back to default SIM not Ins...

Reviews: