Chapter
3:
Web
Management
Diagnostics
‐
VeriPHY
Intelinet
48
‐
Port
Gigabit
Ethernet
PoE+
Managed
Switch
User
Manual
|
326
3.3.3.
Diagnostics
‐
VeriPHY
This
page
is
used
for
running
the
VeriPHY
Cable
Diagnostics
for
10/100
and
1G
copper
ports.
Press
the
“Start”
button
to
run
the
diagnostics.
This
will
take
approximately
5
seconds.
If
all
ports
are
selected,
this
can
take
approximately
15
seconds.
When
completed,
the
page
refreshes
automatically,
and
you
can
view
the
cable
diagnostics
results
in
the
cable
status
table.
Note
that
VeriPHY
is
only
accurate
for
cables
of
length
7
‐
140
meters.
10
and
100
Mbps
ports
will
be
linked
down
while
running
VeriPHY.
Therefore,
running
VeriPHY
on
a
10
or
100
Mbps
management
port
will
cause
the
switch
to
stop
responding
until
VeriPHY
is
complete.
The
ports
belong
to
the
currently
selected
stack
unit,
as
reflected
by
the
page
header.
Port
The
port
where
you
are
requesting
VeriPHY
Cable
Diagnostics.
Cable
Status
Port:
Port
number
Pair:
The
status
of
the
cable
pair.
OK
‐
Correctly
terminated
pair
Open
‐
Open
pair
Short
‐
Shorted
pair
Short
A
‐
Cross
‐
pair
short
to
pair
A
Short
B
‐
Cross
‐
pair
short
to
pair
B
Short
C
‐
Cross
‐
pair
short
to
pair
C
Short
D
‐
Cross
‐
pair
short
to
pair
D
Cross
A
‐
Abnormal
cross
‐
pair
coupling
with
pair
A
Cross
B
‐
Abnormal
cross
‐
pair
coupling
with
pair
B
Cross
C
‐
Abnormal
cross
‐
pair
coupling
with
pair
C