background image

8. Monitor Parameters Settings

Language                            >

User Setup                          >

About                                  >

1.Select About  and 

press 

MENU  Button to 

confirm

2.Press UNLOCK button
and hold for 3seconds

3.Use 

▲ / ▼

 Button to increase 

/ decrease the value; use 

 

Button to select last/next digit.
Press MENU Button to confirm

Exit

About

H/W :                                        a1.2

S/W :                               V01.01.01

Addre

ss

 :                                      

00.00 Video STD :                            

AUTO

Exit

Installer Setup

0

000 ]

Master monitor - code 8000

Slave 1 - code 8001

Slave 2- code 8002

Slave 3- code 8003

Guard Monitor- code 8004, cancel Guard Monitor - code 8005

Power saving mode On - code 8006; Power saving mode Off - 8007 (default)

Unlocking mode for Power-on-to-Open locks - code 8010 (default)

Unlocking Mode for Power-off-to-Open locks - code 8011

One lock mode - 8014 (default)

Two locks mode - 8015

Unlocking time 1-9s - 8021-8029

-

5

-

  

How to enter parameter settings

:

This is the page where the following Codes can be programmed

Summary of Contents for LEDA

Page 1: ... 1 www intelligenthomeonline com LEDA Video Door System 2 wire Series Installation and User Manual Digital 3 5 inch Monitor TALK MENU MONITOR ...

Page 2: ...on the wall 2 Hang the Monitor on the Mounting Bracket firmly 145 160 cm Microphone LCD Screen LED Indicator CALL Button MONITOR Button Direction Button UNLOCK Button TALK Button MENU Button Speaker Mounting Hook Connection Port Peripheral devices DIP Switches 1 2 3 4 5 6 ON TALK MENU MONITOR 1 ...

Page 3: ...f the monitors like a garage shed garden or porch 3 3 Connection To a TV Each monitor can be connected to a TV with antenna cable according the diagram below The core of antenna cable must be connected to the Video and the shield to the GND When the door station rings you don t have to walk to the monitor to see the visitor Instead you can watch the AV channel on the TV and see who is calling 3 1 ...

Page 4: ... the TALK Button on monitor When you are finished press the TALK button again The screen turns off automatically after 40 seconds 3 During talking state Press UNLOCK Button to open the door for the visitor 6 Basic Connection door station BUS IM BUS DS PC6 AC Doorbell Button Switch 1 2 3 4 5 6 ON DIP TALK MENU MONITOR 3 ...

Page 5: ...Setup Instructions Intercom Call Inner Call Call Guard Unit Language User Setup About Exit User Setup Ring Tune Ring Volume Restore Exit User Setup Ring Tune Ring Volume Restore 7 1 Language Select Language on setup page then press MENU button to enter the language page and then use Button to move up down to select the language you want There are eight languages to choose from When Monitor is in s...

Page 6: ... AUTO Exit Installer Setup 0000 Master monitor code 8000 Slave 1 code 8001 Slave 2 code 8002 Slave 3 code 8003 Guard Monitor code 8004 cancel Guard Monitor code 8005 Power saving mode On code 8006 Power saving mode Off 8007 default Unlocking mode for Power on to Open locks code 8010 default Unlocking Mode for Power off to Open locks code 8011 One lock mode 8014 default Two locks mode 8015 Unlockin...

Page 7: ...g or monitoring press UNLOCK button DS 1 00 15 2 Use button to select the lock you want and press MENU button to release the corresponding lock All monitors ring with video power saving mode is turned Off TALK MENU MONITOR TALK MENU MONITOR TALK MENU MONITOR TALK MENU MONITOR Power Saving Mode On Off By default the system is set to power saving mode where only the first monitor with User Code 0 co...

Page 8: ...Code 8 1 2 3 4 5 6 ON Code 19 1 2 3 4 5 6 ON Code 30 1 2 3 4 5 6 ON Code 9 1 2 3 4 5 6 ON Code 20 1 2 3 4 5 6 ON Code 31 1 2 3 4 5 6 ON Code 10 1 2 3 4 5 6 ON Code 21 1 2 3 4 5 6 ON Code 32 1 2 3 4 5 6 ON Code 11 1 2 3 4 5 6 ON Code 22 End of line settings with DIP 6 DIP state Setting DIP state Setting 1 2 3 4 5 6 ON Monitor not at the end of the line 1 2 3 4 5 6 ON Monitor at the end of the line ...

Page 9: ...se button to move left right to select the then use the Button to move up down press MENU Button to select 9 Image and Volume Adjustments 1 Monitor manual monitoring of door station number 1 2 Monitor Doors if multiple door stations are installed you can choose specific door station for manual monitoring Up to 4 Door Station can be connected and monitored 3 Monitor Cameras if system has CCTV camer...

Page 10: ...page 2 Inner Call All Monitors in the House system will ring at the same time When one of the Monitors answers the call all other monitors will stop ringing In Apartments system can be used if multiple monitors has been installed in one of the apartments All monitors should be programmed with same User code In addition one monitor should be programmed as Master and other as slaves 3 Call Guard uni...

Page 11: ... landline number requires an additional TPS Telephone or TPS GSM Interface Up to 3 mobile or landline numbers can be programmed Playback Reserved Light to turn the staircase light The staircase light will be turned off automatically There are 3 Divert Modes to choose from 1 Do not Transfer when you at home and do not want a divert 2 If No Answer if monitor is not answered within 30 seconds call wi...

Page 12: ...y 7 51mA Working status 155mA Monitor screen 3 5 Inch colour LCD Display Resolution 320 R G B x 240 pixels Video signal 1Vp p 75Ω CCIR standard Wiring 2 wires no polarity Monitoring time 40 sec default up to 10min Talking time 90 sec Dimensions H 220 W 105 D 20mm 11 ...

Page 13: ...ce to perform functions for which it is not intended 5 Attaching the device to power supplies other than thoserecommended by the manufacturer Distributor for Warranty purposes Intelligent Home Online Ltd 62 Hartley Old Road Purley Surrey CR8 4HJ 44 0 20 86170015 www intelligenthomeonline com Product _______________________________ Serial Number __________________________________ Invoice Number ___...

Page 14: ... 18 www intelligenthomeonline com Rights to interpret and copyright of this manual are reserved LEDA 2 wire series Designs and specifications may be changed without notice ...

Reviews: